Page 43
AXIOM™ / AXIOM-X™ Product Line Manual
Electrical Installation
4 Electrical Installation WARNING: Electrical Installation by Qualified Service Technicians Only! Several procedures involve exposure to voltage inside the wiring base. A trained technician must perform these procedures. Do not attempt to perform any electrical installation procedures unless you are a trained technician. IMPORTANT: The AXIOM / AXIOM-X contain electronics that may be affected by electrostatic discharge (ESD). To prevent personal injury or damage to the unit, please follow the safety precautions and warnings found in Chapter 2. Failure to follow these precautions may void your warranty.
Preparing for Electrical Installation Before mounting any components, please do the following: Read all instructions before beginning your installation. Define and confirm the accuracy of your application’s requirements. Review the electrical installation drawings provided in Appendix E. Review all installation-specific drawings. Review and plan the power requirements for your application. Review and plan the communications requirements for your application. Install the AXCESS setup software on your laptop or desktop computer. (See Chapter 5, Getting Started.)
04-AXIOM-AXIOM-X_Electrical_Installation_R10.doc
Accu-Sort Systems, Inc.
43
Page 44
44
AXIOM™ / AXIOM-X™ Product Line Manual
Electrical Installation
Installation Sequence(s) NOTE: Everything should be MECHANICALLY INSTALLED before performing any ELECTRICAL INSTALLATION. See Chapter 3 for mechanical installation details. Installing a Single Unit To install a single unit, follow this sequence of steps: Complete mechanical installation. See Chapter 3. Complete electrical installation. Ground the mounting structure to protective earth (PE) ground. Ground the wiring base to protective earth (PE) ground. Connect the power supply to wiring base. CHECK POLARITY. Connect trigger to wiring base. Connect tachometer to wiring base. Connect communications to wiring base. Connect wiring for I/O module(s) to wiring base. Attach scan head to wiring base. NOTE: To reduce the possibility of damage to the scan head, install it after the wiring base is mounted, wired, and all wiring is checked for accuracy. Be sure to perform the polarity check before attaching the scan head. Setup your AXIOM / AXIOM-X. See Chapter 5. Check operations. See Chapter 6.
Installing Multiple Readers For electrical installation, multiple-reader networks will require a different approach to wiring, since the power source, trigger photoeye, and tachometer are most likely being shared by the group of readers. (See drawings 107480 and 107481 in Appendix E.) Special instructions for functional set-up of a multi-reader network are provided in Chapters 5 and 6.
Accu-Sort Systems, Inc.
04-AXIOM-AXIOM-X_Electrical_Installation_R10.doc
Page 45
AXIOM™ / AXIOM-X™ Product Line Manual
Electrical Installation
General Electrical Installation Guidelines It is important that you follow these general precautions when installing, setting up, operating, maintaining, troubleshooting or replacing any AccuSort products, parts or related equipment. CAUTION: The AXIOM / AXIOM-X use lasers for bar code scanning. Do not view directly with optical instruments (binoculars or telescopes). Avoid unintentional exposure to laser light whenever possible.
As you plan and install your AXIOM bar code solution application, be sure to keep the following guidelines in mind: Determine the reader is in the proper orientation and position as outlined in Chapter 3. Allow approximately 8-12 inches [203-305 mm] of clearance for wiring. The wiring base has four conduit openings. Seal unused openings. Use cord grips with rubber grommets on cables that enter the wiring base. Route wires carefully to reduce or minimize electrical noise. When power and communication wiring must cross, make their intersection perpendicular. Proper grounding of the wiring base limits the effects of noise due to Electromagnetic Interference (EMI).
04-AXIOM-AXIOM-X_Electrical_Installation_R10.doc
Accu-Sort Systems, Inc.
45
Page 46
46
AXIOM™ / AXIOM-X™ Product Line Manual
Electrical Installation
Wiring the AXIOM / AXIOM-X After completing mechanical installation, use this section to properly wire you AXIOM reader for optimal performance in your application. All wiring connections are made via the wiring base. Use the four conduit openings for running wires into the base. Route your cabling for input/output power, tachometer, trigger, communications, and I/O, through the recommended conduit openings.
Ethernet and/or Serial
Serial OR I/O Modules, Output Power
Tach and Trigger
Input Power
Wiring tables, printed on the wiring base insulation cover, help simplify installation. Remember: Wire to the terminal blocks, left-to-right, coordinating your wiring with the table, top-to-bottom.
Accu-Sort Systems, Inc.
04-AXIOM-AXIOM-X_Electrical_Installation_R10.doc
Page 47
AXIOM™ / AXIOM-X™ Product Line Manual
Electrical Installation
WARNING: To assure no ESD damage will occur, be sure to observe the precautions outlined in Chapter 2, Safety.
IMPORTANT: Ground the wiring base to safety ground (protective earth ground (PE)). See wiring recommendations for safety ground.
Ground Location for Output Power
Protective Earth Ground
Example of Proper Wiring Only use connectors designed for connecting to aluminum. See also: UL 486B Wire Connectors for use with Aluminum Conductors, UL 486C Splicing Wire Connectors, and UL 486E Equipment Wiring Terminals for use with Aluminum and/or Copper Conductors
04-AXIOM-AXIOM-X_Electrical_Installation_R10.doc
Accu-Sort Systems, Inc.
47
Page 48
48
AXIOM™ / AXIOM-X™ Product Line Manual
Electrical Installation
Cable and Conduit Connections Determine the wiring connections needed for your application. All permanent connections are made to the wiring base with either cables or through conduit. Wiring bases are shipped with four (4) cord grips and three (3) hole plugs. Follow Accu-Sort’s wiring recommendations. Connection
Recommended Wiring Type
Safety Earth Ground
For 15-20 Amp branch circuit, use #18 AWG min. For 16-25 Amp branch circuit, use #14 AWG min. For 26-32 Amp branch circuit, use #12 AWG min. #20 AWG minimum #24 AWG minimum #24 AWG minimum #24 AWG CAT5 UTP (unshielded twisted pair) #24 AWG minimum Depends upon module rating. See Appendix A.
Power RS232 RS422 Ethernet Tach / Trigger I/O Modules
Max. Length
50’ [15.2] 1000’ [300] 330’ [100]
NOTE: ALL external wiring must be UL listed or recognized rated VW-1 or FT-1 and conforming to NEC ANSI/NFPA 70. Cord Grips
Recommended Wiring Diameters
Small Diameter Large Diameter
Accommodates 0.191 to 0.354 inches [4.9 to 9.0 mm] Accommodates 0.236 to 0.472 inches [6.0 to 12.0 mm]
Cable Connections to Wiring Base Where the cabling enters the wiring base, use the supplied cord grips with rubber grommets. Each cord grip comes with two different size grommets. Use the grommet size that provides the tightest fit. NOTE: To maintain the unit’s IP rating, only one cable may be run through each conduit opening. If running two or more cables into one opening, use a plumbing “T” connector to assure the reader will be watertight. Make sure you use Teflon tape (or other thread sealant) to maintain the reader’s IP rating. (AXIOM is IP65, AXIOM-X is IP54.) Once all cabling is completed, plug all unused wiring base openings.
Accu-Sort Systems, Inc.
04-AXIOM-AXIOM-X_Electrical_Installation_R10.doc
Page 49
AXIOM™ / AXIOM-X™ Product Line Manual
Electrical Installation
Conduit Connections to Wiring Base Where the conduit meets with the wiring base, you will need to supply the correct conduit fittings. Use flexible conduit whenever possible to allow for range of motion adjustments, especially when the UMB is used. Once all conduit connections are completed, plug all unused wiring base openings.
Plug Unused Wiring Base Openings Three (3) wiring base hole plugs are supplied. Use these plugs on unused openings. All unused openings MUST be plugged to maintain IP54 rating. Use Teflon tape (or other thread sealant) when inserting the hole plug in the conduit opening. Conduit openings have 1/2-14 NPSC threads. Use an NPSC threaded plug on all unused conduit openings. Tighten hole plug(s) with a 3/8" hex wrench.
04-AXIOM-AXIOM-X_Electrical_Installation_R10.doc
Accu-Sort Systems, Inc.
49
Page 50
50
AXIOM™ / AXIOM-X™ Product Line Manual
Electrical Installation
How to Maintain an IP65 Rating IMPORTANT: Use the Teflon tape provided with the AXIOM / AXIOM-X wiring base to assure the unit maintains its IP65 rating. 1. Wrap the cord grips with Teflon tape. 2. Install the cord grips into the wiring base openings. 3. Assure that the Teflon tape is threaded through the opening. 4. After wiring to the terminal blocks, secure the cables by tightening the cord grip. (Cables should be tight with no slipping when pulled.) 5. Wrap hole plugs with Teflon tape. Seal any unused openings.
Accu-Sort Systems, Inc.
04-AXIOM-AXIOM-X_Electrical_Installation_R10.doc
Page 51
AXIOM™ / AXIOM-X™ Product Line Manual
Electrical Installation
Power Supply Connections CAUTION: While performing the following wiring connection procedures, be sure to follow all safety procedures regarding high-voltage as outlined in Chapter 2, Safety. No power should be applied to any device until all wiring is completed and checked for accuracy. IMPORTANT: All power connections must be quick-disconnect. For PERMANENTLY CONNECTED EQUIPMENT (i.e., reader using DC power) a readily accessible disconnect device must be incorporated in the building installation wiring. For PLUGGABLE EQUIPMENT (i.e., reader using AC power supply with non-detachable power cord), the socket-outlet must be installed near the reader’s power supply. The outlet must be a readily accessible disconnect device. Using Accu-Sort Power Supplies Single Reader The AXIOM readers require 30 watts (maximum) of power. Accu-Sort power supply options are available for either domestic or international installations and are rated for IP40 and IP65 environments. 1. Connect the power supply to the wiring base’s INPUT POWER terminal blocks. The arrow on the figure below indicates the location of the TBs. 2. Make sure wiring cannot come loose. 3. DO NOT over-tighten screws on terminal blocks. 4. The proper location for ground is shown on page 47.
CAUTION: The INPUT POWER wiring table indicates 2.5A output load. This is for applications using other power supplies. The Accu-Sort power supply can handle an output load of 250mA. Multiple Readers When a multiple reader application uses Accu-Sort power supplies, each unit is powered by a separate power supply. DO NOT connect power supplies in parallel. (See drawing 107481 in Appendix E.) AXIOM X-Pattern Applications When using two AXIOMs and the Xpattern mounting bracket (XMB), an Accu-Sort 110W supply is available that provides power to both readers. (See drawing 107480 in Appendix E.)
04-AXIOM-AXIOM-X_Electrical_Installation_R10.doc
Accu-Sort Systems, Inc.
51
Page 52
52
AXIOM™ / AXIOM-X™ Product Line Manual
Electrical Installation
Power Connections Using Other Power Supplies IMPORTANT: All non Accu-Sort power supplies, whether for single or multiple reader applications, must be an LPS or Class 2 power supply. The supply must provide 30 watts (12-30 VDC) of power to each reader.
Single Reader When a single reader application uses a non Accu-Sort supply, follow the INPUT POWER wiring table to assure proper wiring.
Multiple Readers When using a non Accu-Sort supply with multiple readers: 1. Follow the INPUT POWER wiring table to assure proper wiring to the first reader in the wiring daisy-chain. 2. By using the OUTPUT POWER terminal block, a total of three readers may share a power source. NO MORE than three readers may be daisychained to one power source. 3. Wire a cable from the OUTPUT POWER of the first reader to the INPUT POWER of the second reader. 4. Wire a cable from the OUTPUT POWER of the second reader to the INPUT POWER of the third reader. 5. Wiring MUST be grounded at both ends of the INPUT POWER and OUTPUT POWER connection.
Output Power Wiring CAUTION: The OUTPUT POWER wiring table indicates a maximum 2.5A output load. This is only for applications using other power supplies providing a minimum of 86.5 W of power.
Accu-Sort Systems, Inc.
04-AXIOM-AXIOM-X_Electrical_Installation_R10.doc