Page 35

AXIOM™ / AXIOM-X™ Product Line Manual

Mechanical Installation

To install the optional I/O module(s): 1. Lift the insulating cover to gain access to the wiring base. 2. The I/O modules may be plugged into locations I/O 1 through I/O 4. These locations run right-to-left, as shown on the insulating cover label. 3. Plug the appropriate I/O module directly into the wiring base circuit board.

4. Secure the I/O module by tightening the captive screw into the circuit board. DO NOT over-tighten screw.

03-AXIOM-AXIOM-X_Mechanical_Installation_R10.doc

Accu-Sort Systems, Inc.

35

Page 36

36

AXIOM™ / AXIOM-X™ Product Line Manual

Mechanical Installation

Check Scan Head Excessive Shock Indicator IMPORTANT: AXIOM / AXIOM-X scan heads may have been equipped with an excessive shock indicator. The purpose of this indicator is to assure that scan heads that have experienced shock in excess of 75G are not installed at product scan points.

To check the shock indicator before installation: 1. Locate the shock indicator.

AXIOM Scan Head Shock Indicator Location

AXIOM-X Scan Head Shock Indicator Location

2. Confirm if there has been any excessive shock.

GOOD Indicator (no shock, good to install)

BAD Indicator (excessive shock, DO NOT install!)

3. If the indicator is GOOD, the scan head can be installed. 4. If the indicator is BAD, the scan head has experienced excessive shock. DO NOT install the scan head. IMPORTANT: Contact Accu-Sort’s Customer Service department at 1-800-BAR-CODE as soon as possible.

Accu-Sort Systems, Inc.

03-AXIOM-AXIOM-X_Mechanical_Installation_R10.doc

Page 37

AXIOM™ / AXIOM-X™ Product Line Manual

Mechanical Installation

Installing an AXIOM Scan Head Perform the electrical installation as outlined in Chapter 4. Once all wiring is checked for accuracy, install the scan head to the wiring base. The scan head can be installed with or without the power disconnected from the wiring base. To install a scan head: 1. Make sure the insulating cover is in position, so the flap covers the field wiring connections inside the wiring base.

2. Carefully align the 3 scan head alignment pins with the 3 holes in the wiring base. This automatically assures the correct scan head-to-wiring base connector alignment (to avoid bending pins).

03-AXIOM-AXIOM-X_Mechanical_Installation_R10.doc

Accu-Sort Systems, Inc.

37

Page 38

38

AXIOM™ / AXIOM-X™ Product Line Manual

Mechanical Installation

Wiring Base Connector Alignment Pin

Scan Head Connector

3. Gently press the scan head down until it firmly connects with the wiring base. 4. Secure the scan head to the wiring base with the four captive screws.

5. Alternately tighten screws. DO NOT over-tighten screws.

Accu-Sort Systems, Inc.

03-AXIOM-AXIOM-X_Mechanical_Installation_R10.doc

Page 39

AXIOM™ / AXIOM-X™ Product Line Manual

Mechanical Installation

Installing an AXIOM-X Scan Head Perform the electrical installation as outlined in Chapter 4. Once all wiring is checked for accuracy, install the AXIOM-X scan head to the wiring base. You can install the scan head with or without the power disconnected from the wiring base. To install a scan head: 1. Make sure the insulating cover is in position, so the flap covers the field wiring connections inside the wiring base.

2. Use the Safety during AXIOM-X Scan Head Installation procedures. 3. Carefully align the scan head alignment pins with the 3 holes in the wiring base. This assures the correct scan head-to-wiring base connector alignment (to avoid bending pins).

03-AXIOM-AXIOM-X_Mechanical_Installation_R10.doc

Accu-Sort Systems, Inc.

39

Page 40

40

AXIOM™ / AXIOM-X™ Product Line Manual

Mechanical Installation

Wiring Base Connector Alignment Pin

Scan Head Connector

4. Gently press the scan head down until it firmly connects with the wiring base. 5. Secure the scan head to the wiring base with the four captive screws.

6. Alternately tighten screws. DO NOT over-tighten screws.

Accu-Sort Systems, Inc.

03-AXIOM-AXIOM-X_Mechanical_Installation_R10.doc

Page 41

AXIOM™ / AXIOM-X™ Product Line Manual

Mechanical Installation

Safety during AXIOM-X Scan Head Installation CAUTION: Although the scan head only weighs 14.5 lbs [6.6 kg] proper lifting techniques are still required to avoid the potential for back injuries. Top Read Installation with Overhead Space 1. Install scan head onto wiring base with the mounting bracket adjusted as shown. 2. Tighten the four screws that hold the scan head to the wiring base. 3. Adjust mounting bracket angle downward to meet the required application setup.

Direction of Conveyor Travel (Top Read)

Top Read Installation with Limited Overhead Space 1. Install scan head onto wiring base with the mounting bracket adjusted as shown. 2. Use upper body to stabilize scan head as you tighten the four screws that hold it to the wiring base. 3. Adjust mounting bracket angle to required application setup.

Direction of Conveyor Travel (Top Read, limited space)

03-AXIOM-AXIOM-X_Mechanical_Installation_R10.doc

Accu-Sort Systems, Inc.

41

Page 42

42

AXIOM™ / AXIOM-X™ Product Line Manual

Mechanical Installation

Side Read Installation 1. Install scan head onto wiring base with the mounting bracket adjusted as shown. 2. Use upper body or torso to stabilize scan head as you tighten the four screws that hold it to the wiring base. 3. Adjust mounting bracket angle to required application setup.

Direction of Conveyor Travel (Side Read)

Accu-Sort Systems, Inc.

03-AXIOM-AXIOM-X_Mechanical_Installation_R10.doc