Page 26

26

Mechanical Installation

AXIOM™ / AXIOM-X™ Product Line Manual

Installing the IP65-rated power supply: 1. Mount the power supply (1) to the power supply mounting plate (2) with the provided hardware (3). 2. DO NOT over-tighten screws that hold the power supply to the adapter mounting plate. 3. Attach the wiring base/UMB assembly to the mounting structure. 4. Attach the power supply/mounting plate assembly (from step 2) directly to the UMB (4). Insert the two tabs on the edge of the mounting plate into their corresponding locations on the UMB. 5. If the power supply/mounting plate assembly is properly positioned to the UMB, use the screw (located on the opposite edge of the mounting plate from the two tabs) to lock the assembly in place. 6. Continue with the electrical installation. (See Chapter 4.)

Mounting IP65-rated Power Supply to UMB

Accu-Sort Systems, Inc.

03-AXIOM-AXIOM-X_Mechanical_Installation_R10.doc

Page 27

AXIOM™ / AXIOM-X™ Product Line Manual

Mechanical Installation

Attaching the X-Pattern Mounting Bracket (XMB, AXIOM Only) The X-Pattern Mounting Bracket (XMB, part number 0106226002) is an optional accessory that simplifies dual-AXIOM mounting where it is necessary to create an x-scanning pattern.

IMPORTANT: The correct read distance reference plane is from the mounting edge of the XMB and not the AXIOM exit window.

Correct Read Distance Reference Plane (0”) In most instances, the XMB is shipped from the factory pre-assembled.

03-AXIOM-AXIOM-X_Mechanical_Installation_R10.doc

Accu-Sort Systems, Inc.

27

Page 28

28

Mechanical Installation

AXIOM™ / AXIOM-X™ Product Line Manual

Mount wiring bases to XMB: 1. Attach XMB (1) to mounting structure with the provided hardware (2). 2. Mount both wiring bases (3) to the XMB. Use the three screws (4) provided with each wiring base. 3. Insert the screws through the XMB into the threaded holes on bottom of wiring base. DO NOT over-tighten screws. 4. Continue with mounting the power supply to the XMB. (See page 29.)

IMPORTANT: Do not install scan heads to wiring bases until all wiring is completed.

Accu-Sort Systems, Inc.

03-AXIOM-AXIOM-X_Mechanical_Installation_R10.doc

Page 29

AXIOM™ / AXIOM-X™ Product Line Manual

Mechanical Installation

Mount Power Supply to XMB: 1. Mount the power supply (1) to the power supply adapter mounting plate (4) (included with the XMB kit). The XMB kit provides the necessary hardware (2). 2. Attach the power supply/mounting plate assembly directly to the XMB using the provided hardware (3). Fasten to the two tabs on the XMB as shown. DO NOT over-tighten the screws. 3. Continue with the electrical installation. (See Chapter 4.)

IMPORTANT: Do not install scan heads to wiring bases until all wiring is completed.

03-AXIOM-AXIOM-X_Mechanical_Installation_R10.doc

Accu-Sort Systems, Inc.

29

Page 30

30

AXIOM™ / AXIOM-X™ Product Line Manual

Mechanical Installation

Mounting the Trigger Photoeye The standard photoeye works by bouncing a light beam off a reflector and detecting when something breaks the path of light. In order for photoeyes to work properly, make sure the following things are done when mounting the trigger photoeye option: ƒ ƒ ƒ ƒ ƒ ƒ

Mount trigger and reflector so the reader’s scan beam does not strike either of them. Mount a reflector directly opposite the photoeye on the other side of the conveyor. Install the reflector within the operating range of the trigger photoeye. The photoeye must be mounted so the light exit window is perpendicular to the conveyor, facing the reflector. The reflector must be mounted perpendicular to the conveyor, facing the photoeye. When mounting the photoeye to an Accu-Sort structure, see drawing 41222 in Appendix E. IMPORTANT: The trigger photoeye’s beam (between photoeye and reflector) must be blocked by a package before the bar code is in position for scanning. The trigger signal should remain active while the symbol is being scanned. This does NOT apply to tracking applications.

NOTE: The Trigger Photoeye can also be used in a Start/End Trigger application as the Start Trigger Photoeye. In this instance, an End Trigger Photoeye Kit (with DC input module) is also required.

Accu-Sort Systems, Inc.

03-AXIOM-AXIOM-X_Mechanical_Installation_R10.doc

Page 31

AXIOM™ / AXIOM-X™ Product Line Manual

Mechanical Installation

Mounting the Height Tracking Photoeyes Height Tracking Photoeyes are required when package spacing (i.e., distance between packages traveling through the scanning area) is under 1/3 of the total depth of field (DOF). Each additional photoeye cuts the package spacing requirement in half, down to a minimum of 2 inches [50.8 mm]. Up to three photoeyes can be used to divide the DOF into four zones. The following figures illustrate how to divide a 40 inch DOF into four zones to reduce the package spacing requirement to 3.5 inches [88.9 mm].

Height Tracking Photoeyes (Side View) For example: An application with a 30 inch [762 mm] DOF requires minimum package spacing of 10 inches [254 mm]. By adding one Height Tracking Photoeye, this is reduced to 5 inches [127 mm] minimum spacing requirement. Two photoeyes allows spacing of 2.5 inches [63.5 mm].

03-AXIOM-AXIOM-X_Mechanical_Installation_R10.doc

Accu-Sort Systems, Inc.

31

Page 32

32

Mechanical Installation

AXIOM™ / AXIOM-X™ Product Line Manual

Three photoeyes allows spacing of 2 inches [50.8 mm] which is the minimum allowable package spacing. IMPORTANT: Contact Accu-Sort’s Application Engineers for applications requiring package spacing less than two inches [50.8 mm].

Height Tracking Photoeyes (Front View) NOTE: The Height Tracking Photoeye kit includes a DC Input Module that must be installed in the wiring base. See Mounting the I/O Modules. A Height Photoeye Mounting Adapter is also available. (See drawing 112697 in Appendix E.) After electrical installation, settings must also be made in AXCESS. Set the near/far distances in Modify > Tracking. Set the Height Tracking Photoeye distances in Modify > Trigger and Relay Settings. (See Chapter 5.)

Accu-Sort Systems, Inc.

03-AXIOM-AXIOM-X_Mechanical_Installation_R10.doc

Page 33

AXIOM™ / AXIOM-X™ Product Line Manual

Mechanical Installation

Mounting the Tachometer The tachometer (tach) option outputs a set number of pulses for each wheel rotation. This tells the reader the precise conveyor speed, allowing it to determine the exact package position. Tracking allows for multiple boxes to be in the scan window at the same time. Bar codes on each box are decoded and assigned to the correct box. Because most conveyors are unique, providing exact directions for tachometer mounting is difficult. Follow the guidelines below as closely as possible when mounting. Mount the tach on the conveyor section where scanning is performed. Mount the tach on the underside of the conveyor, away from areas where the conveyor bows downward. A good place to mount the tach is underneath the drive shaft. Make sure the tach assembly angles in the same direction that the underside of the conveyor travels. The tach must make good contact with the conveyor. The general mounting kit makes tachometer mounting and setup easier. The extrusion mounting kit (same as shown here) also includes mounting hardware for attaching to Accu-Sort mounting structures. If you are not using the tachometer mounting kit, create a weight or spring assembly to put tension on the back of the tachometer, ensuring that the wheel makes strong contact with the conveyor.

03-AXIOM-AXIOM-X_Mechanical_Installation_R10.doc

Accu-Sort Systems, Inc.

33

Page 34

34

AXIOM™ / AXIOM-X™ Product Line Manual

Mechanical Installation

Mounting the I/O Modules The wiring base supports four (4) optional input or output modules that can be used for trigger inputs or to operate diverters, alarms, etc. The optional I/O modules are not installed at the factory.

I/O Module Location in Wiring Base

I/O Module Applications Output Modules Activate diverter/sorter for no read, multi-read, match, or no match conditions. Activate device (e.g., beacon light) to indicate any of the above conditions. Activate device for use as a “life condition’ indicator. Activate device to follow the trigger condition. Activate alarm. Input Modules Additional photoeye input for Start/End Trigger Additional photoeye input(s) for Height Tracking Photoeyes (up to three) NOTE: The following input module applications require custom software. Transmit photoeye Divert Accomplished photoeye Reboot signal

Accu-Sort Systems, Inc.

03-AXIOM-AXIOM-X_Mechanical_Installation_R10.doc