The text of a manual · part 4 of 26
AXIOM / AXIOM-X Product Line Manual: Chapter 3: Mechanical Installation, pages 17 to 25
Pages 17 to 25 of 230, from AXIOM / AXIOM-X Product Line Manual
The original document is the PDF (7.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Accu-Sort Axiom 400 and Accu-Sort Axiom-X
Page 17
AXIOM™ / AXIOM-X™ Product Line Manual
Mechanical Installation
3 Mechanical Installation This chapter defines a typical AXIOM / AXIOM-X installation and highlights important details that may affect how the reader should be mounted, wired, and configured for optimum performance in your application. Be sure to consider the various factors that affect how the reader must be mounted with respect to the scanning area. IMPORTANT: The AXIOM / AXIOM-X contain electronics that may be affected by electrostatic discharge (ESD). To prevent personal injury or damage to the unit, please follow the safety precautions and warnings found in Chapter 2. Failure to do so may void your warranty.
Preparing to Install Before mounting any components, please do the following: Read all instructions before beginning your installation. Define and confirm the accuracy of your application’s requirements. Review all installation-specific drawings. Review and plan the mechanical installation of all devices used in your application. Be sure to allow adequate clearance for maintenance. Review and plan the power requirements for your application. Check the contents of the shipping cartons against the packing list. Record all product serial numbers. Install the AXCESS setup software on your desktop or laptop computer. (See Chapter 5.) IMPORTANT: The reader’s packaging is designed to protect the unit(s) during shipment. Do not throw it away. Save all packing material in case you need to transport your unit(s). The scan head and wiring base are shipped in separate packages.
03-AXIOM-AXIOM-X_Mechanical_Installation_R10.doc
Accu-Sort Systems, Inc.
17
Page 18
18
AXIOM™ / AXIOM-X™ Product Line Manual
Mechanical Installation
Installation Sequence(s) NOTE: Everything should be MECHANICALLY INSTALLED before performing any ELECTRICAL INSTALLATION. See Chapter 4 for electrical installation details.
Installing a Single Unit To install a single unit, follow this sequence of steps: Complete mechanical installation. Review the details of your application’s requirements. Determine and mark the reader mounting location. Erect mounting frame or other supporting structures. Attach the Universal Mounting Bracket (UMB) to the frame. (UMB and mounting frame options are available from Accu-Sort.) Mount the wiring base to the UMB or frame. Mount the Accu-Sort power supply to the UMB (optional). Mount Trigger Photoeye (optional). Mount Height Tracking Photoeyes (optional). Mount tachometer (optional). Mount I/O modules (optional). Complete electrical installation. See Chapter 4. NOTE: To reduce the possibility of damage to the scan head, install it after the wiring base is mounted, wired, and all wiring is checked for accuracy. Be sure to perform the polarity check before attaching the scan head. Setup your reader. See Chapter 5. Check operations. See Chapter 6.
Installing multiple units To mechanically install multiple units, follow the same sequence of steps, per reader, as defined in Installing a Single Unit. Your application will define how the mounting requirements vary for each reader. Multiple-reader networks may require a different approach to physical location of the power source, trigger photoeye, and tachometer since they are most likely being shared by the group of readers.
Accu-Sort Systems, Inc.
03-AXIOM-AXIOM-X_Mechanical_Installation_R10.doc
Page 19
AXIOM™ / AXIOM-X™ Product Line Manual
Mechanical Installation
Orientation Considerations Consider the important factors that affect how the reader is oriented in respect to the bar coded packages (products) and their method of conveyance. Mounting the reader for optimum performance depends on these factors: Read Range defining the distance (and variations) between the reader and packages, including the near/far distances, and overall depth of field Bar Code Orientation on products (ladder or picket fence) as well as the angle in which codes will appear (skew, pitch and tilt) Reader Positioning for type of scanning required to accommodate picket fence or ladder bar code orientation (yaw, pitch and roll angles)
Read Range The AXIOM / AXIOM-X must be positioned in the scanning area to accommodate reading products over a read range specific to your application. Use the following diagram to determine the near and far read distances. These dimensions result in the overall depth of field your application requires.
Determining Read Range (AXIOM line scanner shown)
03-AXIOM-AXIOM-X_Mechanical_Installation_R10.doc
Accu-Sort Systems, Inc.
19
Page 20
20
AXIOM™ / AXIOM-X™ Product Line Manual
Mechanical Installation
Bar Code Orientation to Scanning Area (AXIOM) Picket Fence or Ladder Orientation Bar code placement usually determines the AXIOM’s positioning. The AXIOM can be mounted to read codes in either a ladder or picket fence orientation.
Picket Fence Orientation
Ladder Orientation
Bar Code Skew, Pitch and Tilt These angles affect bar code readability. Bar codes pitched or skewed up to 45 degrees are still readable. Although some skew may occur, it should not exceed 45 degrees.
Bar Code Tilt, Pitch and Skew Illustrated (AXIOM line scanner shown)
Accu-Sort Systems, Inc.
03-AXIOM-AXIOM-X_Mechanical_Installation_R10.doc
Page 21
AXIOM™ / AXIOM-X™ Product Line Manual
Mechanical Installation
Bar Code Orientation to Scanning Area (AXIOM-X) The AXIOM-X is an omnidirectional bar code reader equipped with DRX technology; bar code orientation limitations that affect readability (e.g., picket fence or ladder) are not issues as they are with typical line scanners. Bar code placement and product orientation requirements are as follows: Product surfaces containing bar codes should be positioned to face the reader. Bar codes should be of good quality. Partially damaged codes can still be decoded as long as all the bars and spaces are visible to the reader. If more than one product surface contains bar codes to be read, multiple readers are needed. Depending on package spacing (i.e., distance between packages as they travel through the scanning area), Height Tracking Photoeyes may be required.
AXIOM-X Orientation with Reference to Conveyor Travel IMPORTANT: There are several parameters associated with the mounting of the AXIOM-X that must be configured to the application. For details, reference Chapter 5. See Modify > Tracking – AXIOM Mounting.
03-AXIOM-AXIOM-X_Mechanical_Installation_R10.doc
Accu-Sort Systems, Inc.
21
Page 22
22
AXIOM™ / AXIOM-X™ Product Line Manual
Mechanical Installation
General Mounting Guidelines As you plan the installation for your application, keep the following in mind: Determine the proper orientation and position of the reader. Allow approximately 8-12 inches [203-305 mm] of clearance. Plan mechanical installation based on the application’s electrical requirements. See General Electrical Installation Guidelines, Chapter 4. Follow all safety precautions when installing, setting up, operating, maintaining, troubleshooting or replacing any Accu-Sort products, parts or related equipment. See Chapter 2, Safety.
Reader Positioning IMPORTANT: The AXIOM readers are able to decode bar codes at a variety of angles; however significant angular distortion may degrade reading performance. When positioning a reader, be aware of how the scanning beam exits the scan window in relation to the wiring base. When mounting the AXIOM readers, take into consideration: The bar code orientation The reader’s scanning beam must intersect entire bar code Range of motion allowed by the Universal Mounting Bracket (UMB)
AXIOM Range of Motion with UMB
AXIOM-X Range of Motion with UMB
Yaw +/- 22.5˚ Roll 360˚ Range of motion when unobstructed with power supply. Downward travel is limited to 105˚. Other obstructions may limit travel. Pitch 50˚ up (max) 130˚ down (max) When on an Accu-Sort mounting structure, re-positioning of mounting bolts may be required.
Accu-Sort Systems, Inc.
03-AXIOM-AXIOM-X_Mechanical_Installation_R10.doc
Page 23
AXIOM™ / AXIOM-X™ Product Line Manual
Mechanical Installation
Dimensions and Clearances The overall dimensions of the AXIOM / AXIOM-X when the Universal Mounting Bracket (UMB) is used are shown on the mechanical specification drawings provided in Appendix E. The reader is a sealed, unventilated unit. No specific clearance is required for the purpose of cooling. However, ease-of-access should be considered when locating the mounting position. NOTE: For installation, maintenance and service, approximately 8-12 inches [203-305 mm] of clearance is recommended.
Attaching the Wiring Base The wiring base and universal mounting bracket may ship pre-assembled. If your application is not using the UMB, mount the wiring base to any flat surface with three mounting screws. The mounting holes in the wiring base have #10-32 UNF-2B threads. The length of the screws must not be greater than 0.5 inch [12.7 mm] plus the thickness of the mounting surface. Create a mounting template using the following diagram.
Wiring Base Mounting Dimensions (not actual size)
03-AXIOM-AXIOM-X_Mechanical_Installation_R10.doc
Accu-Sort Systems, Inc.
23
Page 24
24
Mechanical Installation
AXIOM™ / AXIOM-X™ Product Line Manual
Attaching the Universal Mounting Bracket (UMB) The Universal Mounting Bracket (UMB) simplifies reader mounting and installation. The AXIOM / AXIOM-X both use the same wiring base and UMB. They must be assembled and attached to the mounting structure before beginning wiring procedures. 1. Typically, the UMB and wiring base are pre-assembled. If assembly is required, follow the instructions provided with the UMB. 2. Mount the wiring base (1) to the UMB (3). Use the three screws (4) provided with the wiring base. 3. Insert the screws through the UMB into the threaded holes on bottom of wiring base. Leave the three screws slightly loose. This allows for final adjustment of the reader in relation to the scanning area after wiring is completed. 4. Attach the UMB/wiring base assembly to the mounting structure with the provided hardware (2). 5. DO NOT install the scan head until wiring is complete. 6. Leave slack in cabling/conduit to allow for adjustment. (See Chapter 4.)
Accu-Sort Systems, Inc.
03-AXIOM-AXIOM-X_Mechanical_Installation_R10.doc
Page 25
AXIOM™ / AXIOM-X™ Product Line Manual
Mechanical Installation
Attaching the Power Supply to UMB The power supply accessory is used when an alternative DC power source is not available. Power supplies are available in IP40 and IP65 ratings for both domestic and international applications. The supply and wiring base ships pre-assembled from the factory. If the power supply and UMB have not been pre-assembled, use the correct procedure for the supply provided. Installing the IP40-rated power supply: 1. Plug the AC power cord into the power supply’s IEC connector. 2. Insert the power supply (2) into the mounting bracket (1). 3. Make sure the wires are guided through the wiring notch in the bracket. 4. Use an Allen wrench to attach the power supply mounting bracket (1) to the power supply mounting plate (3) using the four 10-32 hex socket head cap screws (4). DO NOT over-tighten screws. 5. Attach the power supply/mounting plate assembly directly to the UMB (5). Insert the two tabs on the edge of the mounting plate into their corresponding locations on the UMB. 6. If the power supply/mounting plate assembly is properly positioned to the UMB, use the screw (located on the opposite edge of the mounting plate from the two tabs) to lock the assembly in place. 7. Continue with the electrical installation. (See Chapter 4.)
03-AXIOM-AXIOM-X_Mechanical_Installation_R10.doc
Accu-Sort Systems, Inc.
25