Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 20 of 26

AXIOM / AXIOM-X Product Line Manual: Appendices, pages 169 to 177

Pages 169 to 177 of 230, from AXIOM / AXIOM-X Product Line Manual

The original document is the PDF (7.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Accu-Sort Axiom 400 and Accu-Sort Axiom-X

Page 169

AXIOM™ / AXIOM-X™ Product Line Manual

Appendices

A Specifications AXIOM / AXIOM-X Technical Specifications Characteristic Name

Description AXIOM Line Scanning Laser Bar Code Reader AXIOM-X Omnidirectional Laser Bar Code Reader Dimensions AXIOM L 6.23” [158.2 mm] x W 10.87” [276.1 mm] x H 5.19” [131.8 mm] AXIOM-X H 12.23” [311 mm] x W 13.92” [354 mm] x D 6.93” [176 mm] Weight Scan Head: 14.5 lbs. [6.6 kg] Wiring Base: 1.8 lbs. [0.8 kg] Power Supply: (specs on next page) Mounting Bracket: 4.1 lbs. [1.9 kg] including mounting hardware Temperature Operating: +32° F to +122° F [0° to +50° C] Storage: -4° to +158° F [-20° to +70° C] Relative Humidity 10-90% non-condensing Enclosure AXIOM Powdered-Coated Cast Aluminum, rated for IP 65 AXIOM-X Powdered-Coated Cast Aluminum, rated for NEMA 13 / IP54 Power Requirements Input: 12-30 VDC, Typ. 1.0A@24VDC (AXIOM-X only), Max. 5.0A@12VDC Output: Max. 2.5A Load Power Consumption < 40 W Laser Type Visible laser diode <5.0 mW peak at 630-700 nM (standard) AXIOM: Class 3R AXIOM-X: Class 1 Laser Product (IEC-60825-1, 1993+A1: 1997+A2: 2001), Class II Laser Product (21CFR1040) Depth of Field - AXIOM 15-72 inches [381-1829] max. See read charts, Appendix B AXIOM-X Out to 80 inches [2032] max. See read charts, Appendix B Scan Rate AXIOM 700-1400 SPS AXIOM-X 620–1120 SPS Bar Code Types All standard 1D symbologies including: I 2 of 5, Code 128, Code 39, Code 93, Codabar, Codabar NSS, UPC/EAN Visual Indicators LEDs – Status, Trigger, Read, RX/TX, Network, Link, and Read Quality (LEDs 1-5) Connections Dedicated Setup Port: requires AXCESS Setup Programming Cable Terminal Blocks for: Input Power, Output Power, Trigger Input, Tachometer Input, and Communications (Ethernet, Serial, 4 I/O relays) Communications Standard: On-board EtherNet/IP, Ethernet TCP/IP, Serial RS-232, RS-422, and 4 programmable I/O relays Optional: DeviceNet, ProfiBus Software AXIOM Scanning and Decoding Software with DRX (Data Reconstruction) AXCESS Setup Software for AXIOM (Windows-compatible) MTBF > 71,949 hours @ 30° C > 65,500 hours @ 40° C > 48,700 hours @ 50° C Options 9 AXIOM Scan Head Versions – (4) Standard, (4) High-density, (1) Airports X-scanning bracket (supports 2 AXIOM and power supply) AXIOM-X Scan Heads – Standard, Medium, High-Density (2 ea.) 120 VAC or 240 VAC Power Supply Warranty 1-year limited, part and labor; available Blue Ribbon Extended Service Plan (BRES) Service Options Installation assistance and training available from Accu-Sort. Compliance UL, cUL, CE, FCC (Class A) (See Compliance table in this appendix.) Note: Accu-Sort reserves the right to change product specifications without notice.

A1-AXIOM-AXIOM-X_Appendices_R10.doc

Accu-Sort Systems, Inc.

169

Page 170

170

AXIOM™ / AXIOM-X™ Product Line Manual

Appendices

Power Supplies for AXIOM / AXIOM-X IP40- rated Power Supply for AXIOM / AXIOM-X (24V) Characteristic Dimensions Weight Temperature Relative Humidity Enclosure Power Requirements Power Consumption Connections Compliance

Description L 4.65” [118 mm] x W 1.36” [34.5 mm] x H 2.05” [52 mm] 0.6 lbs. [0.275 kg] Operating: 0° to +70° C Storage: -40° to +85° C 5-95% non-condensing ABS plastic, Rated for IP40 Input: 90-264 VAC / 0.5A typical, 1.0A max. @ 120 VAC Output: Max. 250mA Load < 40 W Male IEC (available with either domestic or international power cord) UL, cUL, CE, FCC (Class A) (See Compliance table.)

IP65- rated Power Supply for AXIOM / AXIOM-X (24V) Characteristic Dimensions Weight Temperature Relative Humidity Enclosure Power Requirements Power Consumption Connections Compliance

Description L 6.73” [171 mm] x W 4.76” [121 mm] x H 2.16” [55 mm] 2.5 lbs. [1.1 kg] Operating: 0° to +50° C (+32° F to +122° F) Storage: -20° to +70° C (-4° to +158° F) 10-90% non-condensing Powdered-Coated Cast Aluminum, Rated for IP65 Input: 90-264 VAC / 0.2A typical, 1.0A max. @ 120 VAC Output: Max. 250mA Load < 40 W Male IEC (available with either domestic or international power cord) UL, cUL, CE, FCC (Class A) (See Compliance table.)

Dual AXIOM Power Supply for use with an XMB to create X-pattern Characteristic Dimensions Weight Temperature Relative Humidity Enclosure Power Requirements Power Consumption Connections Compliance

Description L 8.76” [222 mm] x W 5.76” [146 mm] x H 2.18” [55 mm] 4.0 lbs. [1.8 kg] Operating: 0° to +50° C (+32° F to +122° F) Storage: -20° to +70° C (-4° to +158° F) 10-90% non-condensing Powdered-Coated Cast Aluminum, Rated for IP65 90-264 VAC / 0.5A typical, 2.5A max. @ 120 VAC Output: Max. 2.5A Load < 110 W Male IEC (available with either domestic or international power cord) UL, cUL, CE, FCC (Class A) (See Compliance table.)

Note: Accu-Sort reserves the right to change product specifications without notice.

Accu-Sort Systems, Inc.

A1-AXIOM-AXIOM-X_Appendices_R10.doc

Page 171

AXIOM™ / AXIOM-X™ Product Line Manual

Appendices

I/O Modules

Output Modules Part Number Nominal Line Voltage Maximum Line Voltage Minimum Line Voltage Maximum Peak Off State Voltage Maximum Peak Off State Leakage Static off–state dv/dt Maximum On–State Current Minimum On–State Current Maximum 1 Cycle Surge Maximum 1 Second Surge Peak On–State Voltage

1000056136 -60 VDC 3.0 VDC 60 VDC 1.0 mA -0.5 A DC 10 mA DC -1.5 A DC 1.5 V DC

1000056137 120 VAC 140 VAC 12 VAC 400 V peak 2.5 mA RMS 200 V/usec 0.5 A RMS 50mA RMS 4 A peak -1.6 V peak

Input Module Part Number 1000056135 * Maximum Input Voltage 32 VDC Minimum Input Voltage 3.3 VDC Input Resistance 1 k ohm Maximum Input Current 32mA DC@ 32 VDC Drop Out Current 1.0 mA DC Allowable Off–State Input Current 1.0 mA DC Allowable Off–State Input Voltage 2.0 VDC * Note: Compatible with TTL level voltages.

A1-AXIOM-AXIOM-X_Appendices_R10.doc

Accu-Sort Systems, Inc.

171

Page 172

172

AXIOM™ / AXIOM-X™ Product Line Manual

Appendices

Certifications UL Listing

UL Listed UL Listed to Canadian safety standards Standard to which conformity is declared: EN60950: Test Spec: IEC 60950 3RD Edition / (2000) (Information Technology Equipment (I.T.E.), Including Electrical Business Equipment

Standards to which conformity is declared: FCC 47 CFR, Part 15, subpart B, “Unintentional Radiators” CLASS A Radiated Emissions and CLASS B Conducted Emissions

Standards to which conformity is declared: 1 Emissions EN 61000-6-4: 2001 CISPR 11:1999 Radiated Emissions – Class A CISPR 11:1999 Conducted Emissions – Class A 2 Immunity EN 61000-6-2: 2001 Electromagnetic Compatibility - Generic Standards Immunity for industrial environments EN 61000-4-2:1995, Electromagnetic compatibility (EMC), Electrostatic discharge immunity test EN 61000-4-3: 2001, (EMC), Part 4 - Section 3: Radiated, radio-frequency electromagnetic field test EN 61000-4-4:2004, (EMC), Electrical fast transient/burst immunity test EN 61000-4-5:1995, (EMC), Part 4 - Section 5 Surge immunity test EN 61000-4-6:2003, (EMC), Part 4 - Section 6 Immunity to conducted disturbances, induced by radio-frequencies IEC 61000-4-11: 2003, (EMC), Part 4 - Section 11 Voltage dips, short interruptions & variations immunity IEC 61000-3-2 A14, 3/2000 and 61000-3-3: Harmonic current emissions Fluctuating and Steady State Harmonics) ENV 50204: 1995, "(EMC), Radiated, Electromagnetic Field From Digital Radio Telephones-Immunity Test"

Accu-Sort Systems, Inc.

A1-AXIOM-AXIOM-X_Appendices_R10.doc

Page 173

AXIOM™ / AXIOM-X™ Product Line Manual

Appendices

B Read Charts Scan Rate Explained The AXIOM line scanners can be configured with either one or two modules. The AXIOM-X omnidirectional readers are configured with two modules. Each module has the option of having one or two lasers installed, but each module only ever has one mirror wheel and one receiving sensor. AXIOM 1L: These configurations use a single laser in a single module. The AXIOM maximum scan rate is 1,400 SPS. The standard scan rate is 1,100 SPS. (See the read charts for 1000052807 and 1000052809.)

AXIOM 2L: When two lasers are installed in one module, they share the same mirror wheel and sensor. In order to do this, they alternate on and off, and each laser uses every other mirror facet. (See the read charts for 1000052802 and 1000052803.) The AXIOM maximum scan rate when two lasers are installed in one module is 700 scans per second (SPS). The standard scan rate is 550 SPS. AXIOM-X 2L: When one laser is installed in each module, that laser has exclusive use of the mirror wheel and receiving sensor. The AXIOM-X 2L maximum scan rate when one laser is installed per module is 1,120 SPS. The standard scan rate is 1,000 SPS. AXIOM 2L Enhanced: When one laser is installed in each module, that laser has exclusive use of the mirror wheel and receiving sensor. The one laser is on all the time and uses every facet of the mirror wheel. The AXIOM maximum scan rate when one laser is installed per module is 1,400 SPS. The standard scan rate is 1,100 SPS. The scan rate is not additive. When you have two modules in the AXIOM each with one laser each laser is reading over a different zone and the scan rate in that zone is still 1,400 SPS or 1,100 SPS. (See the read charts for 1000052804 and 1000052805.) AXIOM 4L: These units include two modules, each with two lasers per module. (See the read charts for 1000052800 and 1000052801.) AXIOM-X 4L: These scan heads include two modules, each with two lasers per module. The 4L maximum scan rate when two lasers are installed per module is 560 SPS. The standard scan rate is 500 SPS. IMPORTANT: All read charts are applicable to the standard SPS only.

The following labels only appear on the AXIOM-X omnidirectional readers: Identifies a standard density scan head for reading bar codes with minimum bar/space widths of 15 mil+. Identifies a medium density scan head for reading bar codes with minimum bar/space widths of 13 mil+. Identifies a high density scan head for reading bar codes with minimum bar/space widths of 10 mil+.

A1-AXIOM-AXIOM-X_Appendices_R10.doc

Accu-Sort Systems, Inc.

173

Page 174

174

AXIOM™ / AXIOM-X™ Product Line Manual

Appendices

AXIOM 1L Line Scanning Applications (Standard 1000052807 / High Density 1000052809) 10-mil code

(1000052809)

12-mil code

(1000052809)

[Not available at time of publication.]

15-mil code

ƒ ƒ ƒ

1,100 scans per second (standard) throughout DOF ANSI Contrast Grade 84% or greater ANSI “Grade A” Print Quality

Accu-Sort Systems, Inc.

20-mil code

(1000052807)

ƒ ƒ ƒ

(1000052807)

Pitch not greater than +/- 15 ° Skew not greater than +/- 15 ° Tilt not greater than +/- 45 °

A1-AXIOM-AXIOM-X_Appendices_R10.doc

Page 175

AXIOM™ / AXIOM-X™ Product Line Manual

Appendices

AXIOM 2L Line Scanning Applications (Standard 1000052802 / High Density 1000052803)

ƒ ƒ ƒ ƒ

10-mil code

(1000052803)

12-mil code

(1000052803)

15-mil code

(1000052802)

20-mil code

(1000052802)

550 scans per second (standard) throughout DOF Using one receiving sensor Laser pairs alternate on/off every other scan ANSI Contrast Grade 84% or greater

A1-AXIOM-AXIOM-X_Appendices_R10.doc

ƒ ƒ ƒ ƒ

Pitch not greater than +/- 15 ° Skew not greater than +/- 15 ° Tilt not greater than +/- 45 ° ANSI “Grade A” Print Quality

Accu-Sort Systems, Inc.

175

Page 176

176

AXIOM™ / AXIOM-X™ Product Line Manual

Appendices

AXIOM 2L Enhanced Line Scanning Applications (Std. 1000052804 / High Density 1000052805)

ƒ ƒ ƒ ƒ

10-mil code

(1000052805)

12-mil code

(1000052805)

15-mil code

(1000052804)

20-mil code

(1000052804)

1,100 scans per second (standard) throughout DOF Using two receiving sensors, one per module Each laser always on ANSI Contrast Grade 84% or greater

Accu-Sort Systems, Inc.

ƒ ƒ ƒ ƒ

Pitch not greater than +/- 15 ° Skew not greater than +/- 15 ° Tilt not greater than +/- 45 ° ANSI “Grade A” Print Quality

A1-AXIOM-AXIOM-X_Appendices_R10.doc

Page 177

AXIOM™ / AXIOM-X™ Product Line Manual

Appendices

AXIOM 2L Enhanced Line Scanning 45° Skew Apps. (Std. 1000052804 / High Density 1000052805)

10-mil code

12-mil code

(1000052805)

[Not available at time of publication.]

15-mil code

[Not available at time of publication.]

(1000052804)

20-mil code

[Not available at time of publication.]

ƒ ƒ ƒ ƒ

1,100 scans per second (standard) throughout DOF Using two receiving sensors, one per module Each laser always on ANSI Contrast Grade 84% or greater

A1-AXIOM-AXIOM-X_Appendices_R10.doc

(1000052805)

(1000052804)

[Not available at time of publication.]

ƒ ƒ ƒ ƒ

Pitch not greater than +/- 15 ° Skew = 45 ° Tilt not greater than +/- 45 ° ANSI “Grade A” Print Quality

Accu-Sort Systems, Inc.

177