AXIOM / AXIOM-X Product Line Manual: Appendices, pages 178 to 186

Pages 178 to 186 of 230, from AXIOM / AXIOM-X Product Line Manual

The original document is the PDF (7.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Accu-Sort Axiom 400 and Accu-Sort Axiom-X

Page 178

178

AXIOM™ / AXIOM-X™ Product Line Manual

Appendices

AXIOM 4L Line Scanning Applications (Standard 1000052800 / High Density 1000052801)

ƒ ƒ ƒ ƒ

10-mil code

(1000052801)

12-mil code

(1000052801)

15-mil code

(1000052800)

20-mil code

(1000052800)

550 scans per second (standard) throughout DOF Using two receiving sensors, one per module Laser pairs alternate on/off every other scan ANSI Contrast Grade 84% or greater

Accu-Sort Systems, Inc.

ƒ ƒ ƒ ƒ

Pitch not greater than +/- 15 ° Skew not greater than +/- 15 ° Tilt not greater than +/- 45 ° ANSI “Grade A” Print Quality

A1-AXIOM-AXIOM-X_Appendices_R10.doc

Page 179

AXIOM™ / AXIOM-X™ Product Line Manual

Appendices

AXIOM 2L Omnidirectional X-Scanning Application (2) 2L AXIOM and X-Pattern Mounting Bracket (XMB) (Std. 1000052802 / High Density 1000052803) 10-mil code

(1000052803)

12-mil code

(1000052803)

20-mil code

(1000052802)

See page 27.

15-mil code

ƒ ƒ ƒ ƒ

(1000052802)

550 scans per second (standard) throughout DOF Using one receiving sensor Laser pairs alternate on/off every other scan ANSI Contrast Grade 84% or greater

A1-AXIOM-AXIOM-X_Appendices_R10.doc

ƒ ƒ ƒ

Pitch not greater than +/- 15 ° Skew not greater than +/- 15 ° ANSI “Grade A” Print Quality

Accu-Sort Systems, Inc.

179

Page 180

180

AXIOM™ / AXIOM-X™ Product Line Manual

Appendices

AXIOM 2L Enhanced Omnidirectional X-Scanning Application (2) 2L Enhanced AXIOM and X-Pattern Mounting Bracket (XMB) (Std. 1000052804 / High Density 1000052805) 10-mil code

(1000052805)

12-mil code

(1000052805)

20-mil code

(1000052804)

See page 27.

15-mil code

ƒ ƒ ƒ ƒ

(1000052804)

1,100 scans per second (standard) throughout DOF Using two receiving sensors Each laser always on ANSI Contrast Grade 84% or greater

Accu-Sort Systems, Inc.

ƒ ƒ ƒ

Pitch not greater than +/- 15 ° Skew not greater than +/- 15 ° ANSI “Grade A” Print Quality

A1-AXIOM-AXIOM-X_Appendices_R10.doc

Page 181

AXIOM™ / AXIOM-X™ Product Line Manual

Appendices

AXIOM 4L Omnidirectional X-Scanning Applications Using (2) 4L AXIOM and X-Pattern Mounting Bracket (XMB): 1000052800 and 1000052801 10-mil code

(1000052801)

12-mil code

(1000052801)

20-mil code

(1000052800)

See page 27.

15-mil code

ƒ ƒ ƒ ƒ

(1000052800)

550 scans per second (standard) throughout DOF Using two receiving sensors, one per module Laser pairs alternate on/off every other scan ANSI Contrast Grade 84% or greater

A1-AXIOM-AXIOM-X_Appendices_R10.doc

ƒ ƒ ƒ

Pitch not greater than +/- 15 ° Skew not greater than +/- 15 ° ANSI “Grade A” Print Quality

Accu-Sort Systems, Inc.

181

Page 182

182

AXIOM™ / AXIOM-X™ Product Line Manual

Appendices

AXIOM-X Omnidirectional Scanning Applications (Standard Density 2L 1000062887 and 4L 1000062889)

Pitch / skew not greater than + / - 15 ° ANSI Contrast Grade 84% or greater ANSI “Grade A” Print Quality

AXIOM-X 2L = 1000 SPS (standard) throughout the DOF AXIOM-X 4L = 500 SPS (standard) throughout the DOF

Height Tracking Photoeyes are required when package spacing is under 1/3 of the total DOF. See Chapter 3.

Accu-Sort Systems, Inc.

A1-AXIOM-AXIOM-X_Appendices_R10.doc

Page 183

AXIOM™ / AXIOM-X™ Product Line Manual

Appendices

AXIOM-X Omnidirectional Scanning Applications (Medium Density 2L 1000063502 and 4L 1000063503) (High Density 2L 1000062888 and 4L 1000062890)

Pitch / skew not greater than + / - 15 ° ANSI Contrast Grade 84% or greater ANSI “Grade A” Print Quality

AXIOM-X 2L = 1000 SPS (standard) throughout the DOF AXIOM-X 4L = 500 SPS (standard) throughout the DOF

Height Tracking Photoeyes are required when package spacing is under 1/3 of the total DOF. See Chapter 3.

A1-AXIOM-AXIOM-X_Appendices_R10.doc

Accu-Sort Systems, Inc.

183

Page 184

184

Appendices

AXIOM™ / AXIOM-X™ Product Line Manual

Notes:

Accu-Sort Systems, Inc.

A1-AXIOM-AXIOM-X_Appendices_R10.doc

Page 185

AXIOM™ / AXIOM-X™ Product Line Manual

Appendices

C Networking Guide Introduction The AXIOM bar code reader includes a built-in Ethernet interface that can be used both for receiving bar code data from the AXIOM as well as monitoring and configuring the AXIOM.

AXIOM Ethernet Hardware Configuration The AXIOM Ethernet hardware supports a 10/100mbps full or half-duplex Ethernet link. The wiring is described on the label within the AXIOM wiring base. (See Chapter 4.) Industrial environments can be very noisy electrically. This can cause problems with 100mbps Ethernet links. AXIOM operations do not require a high data rate, so the AXIOM default is set at10mbps (full duplex). If your network requires the AXIOM operate at 100mbps, you can still select the higher data rate (or Auto-Detect). Ethernet link errors are more likely to be encountered at this data rate. Try to isolate the Ethernet cabling from electrical noise sources. Use the AXCESS Log Viewer’s DISP ENET command to monitor for Ethernet errors. The AXIOM hardware will detect the swapping of the Transmit and Receive lines and configure appropriately. This allows a straight cable to be used to connect two AXIOMs.

AXIOM Network Software Configuration Before an AXIOM will communicate on your Ethernet network, a few parameters must be set. Initially this must be done by using the AXCESS software and connecting to the AXIOM using the yellow setup programming cable. Once the AXIOM network parameters have been set, AXCESS can be used to connect to the AXIOM over the network. Currently, the AXIOM software only supports static IP addresses. The defaults for the AXIOM network settings are listed below: Parameter IP Address Net Mask Gateway

Default Value 192.0.0.100 255.255.255.0 0.0.0.0

If you are adding your AXIOM to a larger network, you must obtain an IP addresses (as well as the other parameters) from your network administrator. If the AXIOMs are to operate on a closed network, you may assign your own IP addresses. This is typically by just incrementing the last number from the default (192.0.0.101, 192.0.0.102, etc.).

A1-AXIOM-AXIOM-X_Appendices_R10.doc

Accu-Sort Systems, Inc.

185

Page 186

186

AXIOM™ / AXIOM-X™ Product Line Manual

Appendices

Controller/Client Communications Up to six AXIOMs can be configured to operate together as a single unit. All communications between readers is accomplished over an Ethernet network. In this configuration, one AXIOM must be set up as a Controller. The Controller initiates connections with the remaining readers, configuring them to operate as Clients. The trigger input (such as a photoeye) is only connected to the Controller. (See drawings in Appendix E.)

Setting up AXIOMs for a Multi-Reader Network Wiring If only two readers are to be communicating, and the EtherNet network is not needed for diagnostics or host communications, the readers can be connected directly with a CAT5 network cable. However, if connecting them directly with a single cable, the Ethernet Link must be configured for 10mbpsFull Duplex (which is the default). If more than two readers are to be networked or the network needs to be accessible for other reasons, an EtherNet switch is needed. Only provide the trigger signal to the Controller. If a tachometer is in use, it is recommended that it be wired to all readers. However, an option is provided for the Controller to transmit speed messages to the Clients over the network.

Configuration 1. All readers should be operating on the network with unique IP addresses. 2. All AXIOMs that are to communicate together should be assigned the same Group Number. A Group Number of zero (which is the default) disables the Controller/Client capability. 3. The Number of Client Readers should be changed from zero on the Controller in order to identify this unit as the Controller. After being configured as a Controller, it will broadcast messages onto the network to discover the specified number of Clients.

Accu-Sort Systems, Inc.

A1-AXIOM-AXIOM-X_Appendices_R10.doc