The text of a manual · part 19 of 26
AXIOM / AXIOM-X Product Line Manual: Chapter 9: Service
Pages 159 to 168 of 230, from AXIOM / AXIOM-X Product Line Manual
The original document is the PDF (7.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Accu-Sort Axiom 400 and Accu-Sort Axiom-X
Page 159
AXIOM™ / AXIOM-X™ Product Line Manual
Service
9 Service There are a limited number of field-replaceable units (FRUs) that are part of the AXIOM / AXIOM-X Bar Code Reader. In most cases, components should be replaced with a matching recommended spare part (RSP).
Service procedures are divided into two skill levels: Customer technicians (with some training from Accu-Sort) Accu-Sort Trained and Authorized Service Technicians only All AXIOM / AXIOM-X accessories and options are considered customer technician field-replaceable units (FRUs).
Replacement Procedures CAUTION: This symbol indicates you are about to perform an action involving, either a dangerous level of voltage, or to warn against an action that could result in damage to devices or electrical shock. Please follow necessary procedures as outlined in Chapter 2, Safety. ESD CAUTION: This symbol identifies a procedure that requires you take measures to prevent Electrostatic Discharge (ESD) e.g., use an ESD wrist strap. Circuit boards are most at risk. Please follow ESD procedures as outlined in Chapter 2, Safety. External Devices To replace any external devices, reference the installation procedures provided in Chapter 3 and Chapter 4. Field Replaceable Units (FRUs) Replacement procedures for internal field-replaceable units (FRUs) that may be performed by customer technicians are provided with the replacement part. The FRU Quick Reference Guides (QRGs) and “how to” videos are also available on our website www.accusort.com. (Not available at time of publication.) CAUTION: Although someone with basic electromechanical / technical skills may perform the removal and replacement of the field replaceable units (FRUs), Accu-Sort training is recommended. Contact Customer Service at 1-800-BAR-CODE to schedule training that fits your needs.
09-AXIOM-AXIOM-X_Service_R10.doc
Accu-Sort Systems, Inc.
159
Page 160
160
AXIOM™ / AXIOM-X™ Product Line Manual
Service
AXIOM / AXIOM-X Readers # of Readers
FRU Guide N/A
N/A
N/A
Item
Spare Part #
AXIOM Scan Head
1000052807
1-Laser, Standard Density
1000052809
1-Laser, High Density
1000052802
2-Laser/1-Module, Standard Density
1000052803
2-Laser/1-Module, High Density
1000052804
Enhanced: 2-Laser/2-Module, Standard Density
1000052805
Enhanced: 2-Laser/2-Module, Standard Density
1000059582
Enhanced: 2-Laser//2-Module, Airport
1000052800
4-Laser, Standard Density
1000052801
4-Laser, High Density
1000062887
2-Laser, Standard Density
1000063502
2-Laser, Medium Density
1000062888
2-Laser, High Density
1000062889
4-Laser, Standard Density
1000063503
4-Laser, Medium Density
1000062890
4-Laser, High Density
0104636001
Universal Wiring Base for AXIOM / AXIOM-X
AXIOM-X Scan Head
Wiring Base
Replacement Descriptions on site ►
Spares Recommended 1-10
11-30
31-50
NOTE: The illustrated FRU Guides and ‘how to’ videos were not available at the time of publication. When they are completed, they will be placed on the Accu-Sort website (www.accusort.com). Go to: Support > Downloads for the latest information and setup software for AXIOM / AXIOM-X.
Accu-Sort Systems, Inc.
09-AXIOM-AXIOM-X_Service_R10.doc
Page 161
AXIOM™ / AXIOM-X™ Product Line Manual
Service
Accessories # of Readers on site ►
FRU Guide
Item
Spare Part #
Replacement Descriptions
N/A
Power Supply
0112591001
40 watt / 24V (IP40-rated, Domestic)
0112591002
40 watt / 24V (IP40-rated, International)
0105365001
40 watt / 24V (IP65-rated, Domestic)
0105365002
40 watt / 24V (IP65-rated, International)
0105914001
110 watt (IP65-rated, Domestic)
0105914002
110 watt (IP65-rated, International)
1000020569
Kit (flying leads, includes reflector, hardware)
1000063534
Height Tracking Eye Kit (1 photoeye, 1 input module)
N/A
Photoeye
N/A
Tachometer
1000019875
Programmable, 8-30VDC (with 20 ft. cable)
N/A
I/O Modules
1000056135
DC Input Module (White, 3.3-32VDC)
1000056136
DC Output Module (Red, 3-60VDC)
1000056137
AC Output Module (Black, 12-42VAC)
Spares Recommended 1-10
11-30
31-50
NOTE: The illustrated FRU Guides and ‘how to’ videos were not available at the time of publication. When they are completed, they will be placed on the Accu-Sort website (www.accusort.com). Go to: Support > Downloads for the latest information and setup software for AXIOM / AXIOM-X.
09-AXIOM-AXIOM-X_Service_R10.doc
Accu-Sort Systems, Inc.
161
Page 162
162
AXIOM™ / AXIOM-X™ Product Line Manual
Service
Replacing a Scan Head IMPORTANT: If you are installing more than one scan head on a network, install each scan head one at time and set/change the IP address before installing the next scan head. 1. Save configuration parameters from scan head to wiring base or disk. 2. Loosen the four (4) screws that secure the scan head to the wiring base. 3. Pull the scan head straight up from the wiring base. When replacing a scan head, it is not necessary to disconnect the power. 4. Install the replacement scan head by aligning the connector on the scan head with the connector on the wiring base and pressing the scan head down firmly. In applications that are using more than one scan head option, be sure to install the correct scan head by confirming the part number. (See Installing a Scan Head, pages 36-40.) 5. Tighten the four screws that secure the scan head to the wiring base. 6. Set a (unique) IP address for the reader using the AXCESS configuration software. 7. Download the correct reader configuration to the scan head. This can be done in one of three ways: If the parameters from the previous scan head have been saved to the wiring base, you can use the appropriate Toolbar button to restore them. (See Restore Parameters from Wiring Base, page 107.) Download a parameter set you have saved to disk directly through the reader’s Configuration Port Connector using AXCESS and the setup cable.
Accu-Sort Systems, Inc.
09-AXIOM-AXIOM-X_Service_R10.doc
Page 163
AXIOM™ / AXIOM-X™ Product Line Manual
Service
Replacing a Wiring Base 1. Remove power from reader. 2. Unplug power supply from source. 3. Remove the scan head from wiring base. 4. Disconnect all cabling from wiring base terminal blocks. 5. Remove wiring base from UMB/mounting structure. 6. Install wiring base replacement to UMB/mounting structure. 7. Re-connect all wiring to terminal blocks in replacement wiring base. 8. Check power polarity (LED in wiring base). 9. Optional, if used: Check photoeye operation (LED in wiring base). 10. Optional, if used: Check tachometer operation (LED in wiring base). 11. Install the scan head to wiring base. 12. Follow procedure in Chapter 5 to confirm operation. 13. Optional: Backup scan head parameters to wiring base. This assures the parameters are available if the scan head ever needs to be replaced.
09-AXIOM-AXIOM-X_Service_R10.doc
Accu-Sort Systems, Inc.
163
Page 164
164
AXIOM™ / AXIOM-X™ Product Line Manual
Service
Replacing an I/O Module 1. Remove power from reader. 2. Disconnect any other power sources connected to the I/O terminal blocks. 3. Remove the scan head from wiring base. 4. Remove I/O module from wiring base. 5. Install replacement I/O module to correct location on wiring base. 6. Secure I/O module to wiring base. 7. Install the scan head to wiring base. 8. Test operation of device connected to the I/O module.
Accu-Sort Systems, Inc.
09-AXIOM-AXIOM-X_Service_R10.doc
Page 165
AXIOM™ / AXIOM-X™ Product Line Manual
Service
Replacing a Power Supply 1. Remove power from reader. 2. Unplug power supply from source. 3. Remove the scan head from wiring base. 4. Disconnect power supply wiring from INPUT POWER terminal blocks. (See pages 25 and 51.) 5. Mount replacement power supply in same location as faulty unit. 6. Install replacement power supply wiring through correct conduit opening. 7. Connect wiring to INPUT POWER terminal blocks. 8. Confirm power polarity (LED in wiring base). 9. Install the scan head to wiring base.
09-AXIOM-AXIOM-X_Service_R10.doc
Accu-Sort Systems, Inc.
165
Page 166
166
AXIOM™ / AXIOM-X™ Product Line Manual
Service
Replacing a Trigger Photoeye 1. Remove power from reader. 2. Remove the scan head from wiring base. 3. Disconnect photoeye wiring from Trigger terminal blocks. 4. Mount replacement photoeye in same location as faulty photoeye. 5. Install replacement photoeye wiring through correct conduit opening. 6. Connect wiring to Trigger terminal blocks. 7. Confirm photoeye operation (LED in wiring base). 8. Install the scan head to wiring base.
Accu-Sort Systems, Inc.
09-AXIOM-AXIOM-X_Service_R10.doc
Page 167
AXIOM™ / AXIOM-X™ Product Line Manual
Service
Replacing a Tachometer 1. Remove power from reader. 2. Remove the scan head from wiring base. 3. Disconnect tachometer wiring from TACH terminal blocks. 4. Mount replacement tachometer in same location as faulty tachometer. 5. Install replacement tachometer wiring through correct conduit opening. 6. Connect wiring to TACH terminal blocks. 7. Install the two ferrite clamps on the TACH cable. 8. Confirm tachometer operation (LED in wiring base). 9. Install the scan head to wiring base.
09-AXIOM-AXIOM-X_Service_R10.doc
Accu-Sort Systems, Inc.
167
Page 168
168
Service
AXIOM™ / AXIOM-X™ Product Line Manual
Notes:
Accu-Sort Systems, Inc.