Page 159

AXIOM™ / AXIOM-X™ Product Line Manual

Service

9 Service There are a limited number of field-replaceable units (FRUs) that are part of the AXIOM / AXIOM-X Bar Code Reader. In most cases, components should be replaced with a matching recommended spare part (RSP).

Service procedures are divided into two skill levels: Customer technicians (with some training from Accu-Sort) Accu-Sort Trained and Authorized Service Technicians only All AXIOM / AXIOM-X accessories and options are considered customer technician field-replaceable units (FRUs).

Replacement Procedures CAUTION: This symbol indicates you are about to perform an action involving, either a dangerous level of voltage, or to warn against an action that could result in damage to devices or electrical shock. Please follow necessary procedures as outlined in Chapter 2, Safety. ESD CAUTION: This symbol identifies a procedure that requires you take measures to prevent Electrostatic Discharge (ESD) e.g., use an ESD wrist strap. Circuit boards are most at risk. Please follow ESD procedures as outlined in Chapter 2, Safety. External Devices To replace any external devices, reference the installation procedures provided in Chapter 3 and Chapter 4. Field Replaceable Units (FRUs) Replacement procedures for internal field-replaceable units (FRUs) that may be performed by customer technicians are provided with the replacement part. The FRU Quick Reference Guides (QRGs) and “how to” videos are also available on our website www.accusort.com. (Not available at time of publication.) CAUTION: Although someone with basic electromechanical / technical skills may perform the removal and replacement of the field replaceable units (FRUs), Accu-Sort training is recommended. Contact Customer Service at 1-800-BAR-CODE to schedule training that fits your needs.

09-AXIOM-AXIOM-X_Service_R10.doc

Accu-Sort Systems, Inc.

159

Page 160

160

AXIOM™ / AXIOM-X™ Product Line Manual

Service

AXIOM / AXIOM-X Readers # of Readers

FRU Guide N/A

N/A

N/A

Item

Spare Part #

AXIOM Scan Head

1000052807

1-Laser, Standard Density

1000052809

1-Laser, High Density

1000052802

2-Laser/1-Module, Standard Density

1000052803

2-Laser/1-Module, High Density

1000052804

Enhanced: 2-Laser/2-Module, Standard Density

1000052805

Enhanced: 2-Laser/2-Module, Standard Density

1000059582

Enhanced: 2-Laser//2-Module, Airport

1000052800

4-Laser, Standard Density

1000052801

4-Laser, High Density

1000062887

2-Laser, Standard Density

1000063502

2-Laser, Medium Density

1000062888

2-Laser, High Density

1000062889

4-Laser, Standard Density

1000063503

4-Laser, Medium Density

1000062890

4-Laser, High Density

0104636001

Universal Wiring Base for AXIOM / AXIOM-X

AXIOM-X Scan Head

Wiring Base

Replacement Descriptions on site ►

Spares Recommended 1-10

11-30

31-50

NOTE: The illustrated FRU Guides and ‘how to’ videos were not available at the time of publication. When they are completed, they will be placed on the Accu-Sort website (www.accusort.com). Go to: Support > Downloads for the latest information and setup software for AXIOM / AXIOM-X.

Accu-Sort Systems, Inc.

09-AXIOM-AXIOM-X_Service_R10.doc

Page 161

AXIOM™ / AXIOM-X™ Product Line Manual

Service

Accessories # of Readers on site ►

FRU Guide

Item

Spare Part #

Replacement Descriptions

N/A

Power Supply

0112591001

40 watt / 24V (IP40-rated, Domestic)

0112591002

40 watt / 24V (IP40-rated, International)

0105365001

40 watt / 24V (IP65-rated, Domestic)

0105365002

40 watt / 24V (IP65-rated, International)

0105914001

110 watt (IP65-rated, Domestic)

0105914002

110 watt (IP65-rated, International)

1000020569

Kit (flying leads, includes reflector, hardware)

1000063534

Height Tracking Eye Kit (1 photoeye, 1 input module)

N/A

Photoeye

N/A

Tachometer

1000019875

Programmable, 8-30VDC (with 20 ft. cable)

N/A

I/O Modules

1000056135

DC Input Module (White, 3.3-32VDC)

1000056136

DC Output Module (Red, 3-60VDC)

1000056137

AC Output Module (Black, 12-42VAC)

Spares Recommended 1-10

11-30

31-50

NOTE: The illustrated FRU Guides and ‘how to’ videos were not available at the time of publication. When they are completed, they will be placed on the Accu-Sort website (www.accusort.com). Go to: Support > Downloads for the latest information and setup software for AXIOM / AXIOM-X.

09-AXIOM-AXIOM-X_Service_R10.doc

Accu-Sort Systems, Inc.

161

Page 162

162

AXIOM™ / AXIOM-X™ Product Line Manual

Service

Replacing a Scan Head IMPORTANT: If you are installing more than one scan head on a network, install each scan head one at time and set/change the IP address before installing the next scan head. 1. Save configuration parameters from scan head to wiring base or disk. 2. Loosen the four (4) screws that secure the scan head to the wiring base. 3. Pull the scan head straight up from the wiring base. When replacing a scan head, it is not necessary to disconnect the power. 4. Install the replacement scan head by aligning the connector on the scan head with the connector on the wiring base and pressing the scan head down firmly. In applications that are using more than one scan head option, be sure to install the correct scan head by confirming the part number. (See Installing a Scan Head, pages 36-40.) 5. Tighten the four screws that secure the scan head to the wiring base. 6. Set a (unique) IP address for the reader using the AXCESS configuration software. 7. Download the correct reader configuration to the scan head. This can be done in one of three ways: If the parameters from the previous scan head have been saved to the wiring base, you can use the appropriate Toolbar button to restore them. (See Restore Parameters from Wiring Base, page 107.) Download a parameter set you have saved to disk directly through the reader’s Configuration Port Connector using AXCESS and the setup cable.

Accu-Sort Systems, Inc.

09-AXIOM-AXIOM-X_Service_R10.doc

Page 163

AXIOM™ / AXIOM-X™ Product Line Manual

Service

Replacing a Wiring Base 1. Remove power from reader. 2. Unplug power supply from source. 3. Remove the scan head from wiring base. 4. Disconnect all cabling from wiring base terminal blocks. 5. Remove wiring base from UMB/mounting structure. 6. Install wiring base replacement to UMB/mounting structure. 7. Re-connect all wiring to terminal blocks in replacement wiring base. 8. Check power polarity (LED in wiring base). 9. Optional, if used: Check photoeye operation (LED in wiring base). 10. Optional, if used: Check tachometer operation (LED in wiring base). 11. Install the scan head to wiring base. 12. Follow procedure in Chapter 5 to confirm operation. 13. Optional: Backup scan head parameters to wiring base. This assures the parameters are available if the scan head ever needs to be replaced.

09-AXIOM-AXIOM-X_Service_R10.doc

Accu-Sort Systems, Inc.

163

Page 164

164

AXIOM™ / AXIOM-X™ Product Line Manual

Service

Replacing an I/O Module 1. Remove power from reader. 2. Disconnect any other power sources connected to the I/O terminal blocks. 3. Remove the scan head from wiring base. 4. Remove I/O module from wiring base. 5. Install replacement I/O module to correct location on wiring base. 6. Secure I/O module to wiring base. 7. Install the scan head to wiring base. 8. Test operation of device connected to the I/O module.

Accu-Sort Systems, Inc.

09-AXIOM-AXIOM-X_Service_R10.doc

Page 165

AXIOM™ / AXIOM-X™ Product Line Manual

Service

Replacing a Power Supply 1. Remove power from reader. 2. Unplug power supply from source. 3. Remove the scan head from wiring base. 4. Disconnect power supply wiring from INPUT POWER terminal blocks. (See pages 25 and 51.) 5. Mount replacement power supply in same location as faulty unit. 6. Install replacement power supply wiring through correct conduit opening. 7. Connect wiring to INPUT POWER terminal blocks. 8. Confirm power polarity (LED in wiring base). 9. Install the scan head to wiring base.

09-AXIOM-AXIOM-X_Service_R10.doc

Accu-Sort Systems, Inc.

165

Page 166

166

AXIOM™ / AXIOM-X™ Product Line Manual

Service

Replacing a Trigger Photoeye 1. Remove power from reader. 2. Remove the scan head from wiring base. 3. Disconnect photoeye wiring from Trigger terminal blocks. 4. Mount replacement photoeye in same location as faulty photoeye. 5. Install replacement photoeye wiring through correct conduit opening. 6. Connect wiring to Trigger terminal blocks. 7. Confirm photoeye operation (LED in wiring base). 8. Install the scan head to wiring base.

Accu-Sort Systems, Inc.

09-AXIOM-AXIOM-X_Service_R10.doc

Page 167

AXIOM™ / AXIOM-X™ Product Line Manual

Service

Replacing a Tachometer 1. Remove power from reader. 2. Remove the scan head from wiring base. 3. Disconnect tachometer wiring from TACH terminal blocks. 4. Mount replacement tachometer in same location as faulty tachometer. 5. Install replacement tachometer wiring through correct conduit opening. 6. Connect wiring to TACH terminal blocks. 7. Install the two ferrite clamps on the TACH cable. 8. Confirm tachometer operation (LED in wiring base). 9. Install the scan head to wiring base.