Page 149
AXIOM™ / AXIOM-X™ Product Line Manual
Troubleshooting
The Read Rate Log Viewer also provides performance information on each laser. In order to provide diagnostics on the performance of each laser, the percentages reference here are the percentage of the total codes read by the particular laser, NOT the percentage of the total packages read by that laser. Read Rate Counters per Laser Read Rate Total Codes Laser#x
Description Total number of bar codes read. Total number of bar codes read by the particular laser.
For an AXIOM configured as a Controller in a multi-reader network, this command also provides counters for the number of bar codes read, by laser, for each AXIOM client. The clients are identified by their reader name as assigned in the Modify > AXIOM Configuration window of AXCESS. (See Chapter 5.) REMEMBER: Not every AXIOM is configured with four lasers.
08-AXIOM-AXIOM-X_Troubleshooting_R10.doc
Accu-Sort Systems, Inc.
149
Page 150
150
AXIOM™ / AXIOM-X™ Product Line Manual
Troubleshooting
System Counters Log View You can display a number of values and counters that indicate whether the AXIOM is configured and operating properly by clicking the System Counters button. You can also enter DISPCOUNTERS in the command field and click Send.
Scan Rate and Belt Speed System Counters Scan Rate
Belt Speed
Accu-Sort Systems, Inc.
Description This is the total number of scans/second that the AXIOM is reading. Note the this number does NOT take into account “laser toggling” if it is enabled. If “laser toggling” is enabled, the effective scan rate for any laser is half of this value. (tracking) Speed of the belt (in ft/min) as measured by the tachometer.
08-AXIOM-AXIOM-X_Troubleshooting_R10.doc
Page 151
AXIOM™ / AXIOM-X™ Product Line Manual
Bar Code Counters Triggers Good Reads
No Reads Mult Codes
Match Codes Bad ModChk
Error Counters Xfter Ovrflw
Xfer BadLen
QData@TX
QData@Trig
ForcedTx
Lost Codes
Missed Tx
08-AXIOM-AXIOM-X_Troubleshooting_R10.doc
Troubleshooting
Description Total number of packages based on the trigger signal. In self-trigger mode, this will match the number of good reads. Total number of bar codes read and transmitted. If the AXIOM is set up to read multiple bar codes each trigger, this counter is incremented for each bar code read. Total number of bar codes that were not read. Total number of instances where more bar codes of a specific type were read than expected. This counter will also increment, regardless of whether the AXIOM is configured to report “multiple codes” as an error. Total number of bar codes that matched any of the Match Code criteria. Total number of bar codes that were rejected due to an invalid Mod Check.
Description Transfer Overflow. This counts the number of codes that were lost due to an overflow in the transfer buffer between the Decode/DSP processor and the AXIOM/ARM processor. Transfer Bad Length. Number of codes in the transfer buffer than contained an invalid length, indicating some sort of memory corruption. Queue Data at Transmit (non-tracking). This counter indicates that the AXIOM had not completed processing all of the scan data at the user specified transmit time. This will only happen if the “transmit time” parameter is set to a value other than zero. This does not necessarily indicate an error, but does indicate that either the transmit time is too short or the AXIOM is seeing a lot of data which may be the result of too much background noise. Queue Data at Trigger (non-tracking). This counter indicates that the AXIOM had not completed processing all of the scan data prior to the start of the next trigger. This typically can only happen when the “transmit time” parameter is set to zero; although it can also happen in conjunction with a Force Transmit. As with the Queue Data at Transmit counter, this does not necessarily indicate an error, but it likely indicates that the AXIOM is seeing a lot of data which may be the result of too much background noise. Forced Transmit (non-tracking). A forced transmit indicates that the start of trigger occurred before the specified transmit delay time had expired. Lost Codes (tracking). If a bar code cannot be placed onto any package while in tracking, the code is “lost” and this counter is incremented. Lost codes are also reported in the AXIOM Monitor message window. Lost code occurances typically indicate tracking parameters need to be adjusted. Missed Transmit (tracking). If a bar code is decoded after the message for that package has been transmitted, the Missed Transmit counter is incremented.
Accu-Sort Systems, Inc.
151
Page 152
152
AXIOM™ / AXIOM-X™ Product Line Manual
Troubleshooting
Decode/DSP Counters DSP Codes Scan Ints Queue Size Num Cluster Bad Scan Pipe Error Full Scans Mem Full ScanTooLong Max Clusters
ARM / DSP Restarts Counters ARM Restarts
DSP Restarts
Accu-Sort Systems, Inc.
Description Count of the number of barcodes decoded, per laser, by the DSP. Number of scan interupts detected by the DSP. Current size of the scan data queue within the DSP. This value changes dynamically. Current number of DRX clusters in use by the DSP. This value changes dynamically. Count of the number of scans in which the data contained formatting errors. Count of internal errors on the transfer of scan data from the scan data buffer. Number of times a scan could not be added to the scan data buffer because the maximum number of scans was exceeded. Number of times a scan could not be added to the scan data buffer because the memory was full. Number of times a scan was skipped because it contained too many transitions. Number of times, the maximum number of DRX clusters was exceeded.
Description Number of times the ARM processor has restarted. This typically means the hardware watchdog timer expired causing the ARM processor to restart. Number of times the DSP processor has been restarted. Typically, this happens if the ARM suspects the DSP has “locked up” for any reason.
08-AXIOM-AXIOM-X_Troubleshooting_R10.doc
Page 153
AXIOM™ / AXIOM-X™ Product Line Manual
Troubleshooting
Message Log View The Message Log contains various text messages that have been logged by the AXIOM software. You can view these messages by clicking the Message Log button. You can also enter DISPMSGLOG in the command field and click Send.
The messages contained in this log typically reflect significant events.
08-AXIOM-AXIOM-X_Troubleshooting_R10.doc
Accu-Sort Systems, Inc.
153
Page 154
154
Troubleshooting
AXIOM™ / AXIOM-X™ Product Line Manual
Display Lasers Log View The Display Lasers command provides a summary of the scan data being detected by each laser. You can also enter DISPLASERS in the command field and click Send.
Accu-Sort Systems, Inc.
08-AXIOM-AXIOM-X_Troubleshooting_R10.doc
Page 155
AXIOM™ / AXIOM-X™ Product Line Manual
Troubleshooting
Details of each laser can be seen with the DISP LASERx command (where x is the laser number). For each transition, the raw position and bar width is shown first. After that (with brackets), the computed bar and space values are displayed. A zero is used if the bar or space exceeds the minimum or maximum bar/space width threshold for that laser.
08-AXIOM-AXIOM-X_Troubleshooting_R10.doc
Accu-Sort Systems, Inc.
155
Page 156
156
AXIOM™ / AXIOM-X™ Product Line Manual
Troubleshooting
Update Firmware CAUTION: Used to reload AXIOM reader firmware. This function should only be performed under the guidance of Accu-Sort Technical Support.
Extracting an Image: 1. Click the Extract Image button. 2. The Save As window enables you to save image (*.img) files. Burning an Image to Flash: 1. Click the Burn Flash button. 2. The Open window enables you to open an image file (*.im*) 3. Burn the image file to flash.
Accu-Sort Systems, Inc.
08-AXIOM-AXIOM-X_Troubleshooting_R10.doc
Page 157
AXIOM™ / AXIOM-X™ Product Line Manual
Troubleshooting
PCS Troubleshooting Tables The following PCS (problem/cause/solution) tables are designed to assist you in troubleshooting the more common events that may occur during installation and operation. Problem Cause(s) Solution(s)
Problem Cause(s) Solution(s)
Problem Cause(s)
Solution(s)
08-AXIOM-AXIOM-X_Troubleshooting_R10.doc
The POLARITY LED in the wiring base is RED. Wiring from the power supply to the INPUT POWER terminal block is incorrectly wired. IMPORTANT: DO NOT install the scan head if polarity LED is RED. 1. Correct the polarity problem by swapping the wires at the INPUT POWER terminal block. 2. Confirm power polarity is correct (GREEN LED). 3. Install the scan head. (See Chapter 3.) There is no laser light exiting from the reader when power is activated. Have the laser(s) been shut off? (See page 132.) No power is provided to the AXIOM. 1. Check to ensure power is properly connected. 2. Check to see if AXIOM Status LED turns ON. 3. Confirm power supply functioning. 4. Remove AXIOM-X scan head from wiring base. 5. Verify Power LED in wiring base is GREEN. 6. If Power LED is RED, polarity is swapped. 7. If Power LED is OFF, check wiring at the INPUT POWER terminal block. 8. Replace the power supply if wiring was correct. 9. Reassemble AXIOM-X scan head to wiring base. The AXIOM / AXIOM-X is not reading bar codes. Code type is not enabled or wrong code length. Code passes by at too large an angle (tilt, pitch, skew). All codes have very poor print quality. 1. Enable code type or correct code length. 2. Make sure laser beam is ON when code passes by. 3. Verify correct bar code parameters are enabled. 4. Enable TEST MODE. (Use either the AXIOM control panel button or AXCESS Tools > AXIOM Commands > Test Mode On.) 5. Hold code in the scan line. 6. Verify the AXIOM is reading the code. 7. Correct any tilt, pitch, or skew problems. 8. Remedy bar code printing problems.
Accu-Sort Systems, Inc.
157
Page 158
158
AXIOM™ / AXIOM-X™ Product Line Manual
Troubleshooting
Problem Cause(s)
Solution(s)
Problem Cause(s) Solution(s)
The reader is experiencing poor read rate in hardware trigger. Photoeye is not adjusted properly or requires alignment. 1. Verify that the photoeye is blocked the entire time the reader’s laser is scanning the bar code. 2. Adjust the photoeye as necessary. (See Verify Photoeye Operation, page 135.) NOTE: For non-tracking applications only.
Problem Cause(s)
HOST is not receiving serial host message. Improper wiring between host and reader. Incorrect configuration settings. 1. Is the RX/TX LED flashing GREEN? 2. If yes, check the serial cable wiring at the wiring base’s SERIAL COM terminal block and at the HOST. 3. If no, verify the trigger input and trigger configuration. 4. View the Message Monitor to verify the reader is transmitting data from the SERIAL COM port. (Reference AXCESS software, Diagnostics > AXIOM Monitor.)
Solution(s)
Problem Cause(s) Solution(s)
Problem Cause(s) Solution(s)
Accu-Sort Systems, Inc.
The reader is experiencing poor read rate. Poorly printed bar codes. Scan head window is dirty. Codes passing by at too large an angle (tilt, pitch, skew). 1. Confirm the quality of bar code printing is good enough to read. Correct any print quality issues. 2. Clean scan head window as defined on page 134. 3. Check reading distance with a known good quality sample bar code. 4. Enable TEST MODE. (Use either the AXIOM-X control panel button or AXCESS Tools > AXIOM Commands > Test Mode On.) 5. Hold code in the scan line. 6. Verify the AXIOM-X is reading the code. 7. Correct any tilt, pitch, or skew problems.
Reads bar codes, but transmits a NO READ message. (Tracking Applications Only) Improper tracking configuration 1. Check for “Code Lost” messages using AXCESS diagnostics. 2. If “Code Lost” messages are present, check the tracking configuration. (Reference AXCESS Software, Tracking.) 3. Correct as needed. Cannot connect configuration PC running AXCESS to the reader’s Ethernet port. Improperly configured Ethernet port on configuration PC 1. Verify network port configuration on PC. 2. Port on PC must be configured for a static IP address.
08-AXIOM-AXIOM-X_Troubleshooting_R10.doc