Page 139
AXIOM™ / AXIOM-X™ Product Line Manual
Troubleshooting
8 Troubleshooting This chapter provides instructions for diagnosing, troubleshooting and correcting AXIOM / AXIOM-X performance issues. It provides specific information on: ƒ
Test Mode
ƒ
Indicators
ƒ
Diagnostics
ƒ
Troubleshooting (Problem/Cause/Solution)
Test Mode In test mode, the reader displays the read rate on the AXIOM-X control panel’s bargraph LEDs. The AXCESS Diagnostics > AXIOM Monitor window also provides a read quality bargraph that enables you to monitor the test mode remotely from a PC connected to your network. Additional details can be obtained by monitoring from this diagnostic window while the reader is in test mode. When test mode is selected, either by using the control panel button or AXCESS software, it will “time out” after three minutes.
Status Indicators The AXIOM / AXIOM-X provides several status indicators that you can use to troubleshooting performance during operations. They are found at two locations:
08-AXIOM-AXIOM-X_Troubleshooting_R10.doc
ƒ
Control Panel
ƒ
AXCESS Diagnostics > AXIOM Monitor screen
Accu-Sort Systems, Inc.
139
Page 140
140
Troubleshooting
AXIOM™ / AXIOM-X™ Product Line Manual
Control Panel Status Indicators There are several control panel status indicators on the scan heads.
Accu-Sort Systems, Inc.
08-AXIOM-AXIOM-X_Troubleshooting_R10.doc
Page 141
AXIOM™ / AXIOM-X™ Product Line Manual
Troubleshooting
Control Panel LED Fault Detect Descriptions LED
Description
STATUS
RED indicates a problem regarding the overall "health" of the reader.
TRIGGER
Indicates the trigger input. The LED is controlled through software no matter the trigger source (including software trigger).
READ
RED identifies a No Read condition. Check bar code print quality, trigger configuration, and bar code parameters.
RX/TX
If bar codes are being read, but the LED is NOT illuminated, data is not being transmitted on serial port 1.
NETWORK
(See Network LED – Fault Detection.)
LINK
If the LED is not flashing, there is no network connection.
Bar Graph
Read quality indicator (5 = Good, 1 = Poor).
(LED 1 – 5)
5 = 81-100% 4 = 61-80% 3 = 41-60% 2 = 21-40% 1 = 00-20% NOTES: Also flashes during parameter upload/backup.
(Laser Shutoff)
08-AXIOM-AXIOM-X_Troubleshooting_R10.doc
LEDs stay on when Test/Diagnostic button C is pressed during the laser shutoff procedure. (See page 132.)
Accu-Sort Systems, Inc.
141
Page 142
142
AXIOM™ / AXIOM-X™ Product Line Manual
Troubleshooting
NETWORK LED – Fault Detection Only Mode Single TCP/IP
Description LED is Off – No host connection or UDP messaging is used. NOTE: If UDP messaging is used (unconnected messages) the Network LED will be off. EtherNet/IP Flashing GREEN – No connection made with the network Flashing RED – Lost network connection Controller/Client Controller Flashing RED – All the client(s) with the same group number have NOT been found or a client’s tracking does not match the controller. Client Off – Not connected to a controller with the same group number. Match the client to the controller’s group number. Solid RED – Client’s tracking does not match the controller. NOTE: The mode indicated by the Network LED is dependent on the AXIOM configuration you are using. Ethernet/IP is the highest priority, Single TCP/IP mode operation is the lowest. NOTE: See Network LED during Normal Operations in Chapter 6.
Control Panel Buttons – Uses during Troubleshooting Ref. A
Button
Description
Restore to AXIOM
Use to restore a set of parameters from the wiring base to a replacement scan head. NOTE: This only works if the Backup to Base button has been used earlier to assure the correct parameters are stored in the wiring base. See procedure on page 123.
B
Backup to Base
When it becomes necessary to replace a scan head, be sure to use this button to download a backup set of parameters from the scan head to the wiring base. By doing this, it is easy to configure your replacement scan head by using the Upload to AXIOM button. See procedure on page 123.
C
Test /Diagnostic
Enables the AXIOM test mode.
(Laser Shutoff)
(Test mode can also be selected remotely using AXCESS Tools > AXIOM Commands > Test Mode On.) Use to perform laser shutoff. (See page 132.)
NOTE: Keep in mind that the buttons on the reader’s control panel can be enabled/disabled through the use of the AXCESS setup software. (For details, see Modify > AXIOM Configuration in Chapter 5.)
Accu-Sort Systems, Inc.
08-AXIOM-AXIOM-X_Troubleshooting_R10.doc
Page 143
AXIOM™ / AXIOM-X™ Product Line Manual
Troubleshooting
Wiring Base Status Indicators
Tach LED
Trigger LED
Polarity LED
Wiring Base Status LED Descriptions
08-AXIOM-AXIOM-X_Troubleshooting_R10.doc
Status LEDs Polarity
Location / Definition
Tach
On outside edge of circuit board, behind scan head connector. If tachometer wheel is slowly rotated, the Tach LED will flash GREEN. (See Verify Tachometer Operation, page 136.)
Trigger
On outside edge of circuit board, behind scan head connector. When the trigger photoeye is blocked, the Trigger LED will light GREEN. (See Verify Trigger Photoeye Operation, page 135.)
Near input power TB. Also referred to as Power LED. RED if power polarity is reversed. GREEN if power polarity is correct. OFF indicates no power. DO NOT install the scan head if this LED is RED.
Accu-Sort Systems, Inc.
143
Page 144
144
AXIOM™ / AXIOM-X™ Product Line Manual
Troubleshooting
Diagnostics The AXCESS for AXIOM software includes comprehensive diagnostic capabilities that monitor reader operation, triggering, conveyor speed, package and label dimensions, bar code readability, scan rates and message output. The Diagnostics > AXIOM Monitor window is the primary tool used to monitor the reader's operation and bar code readability in real-time. The Diagnostics > Log Viewer lets you review the performance logs saved by the AXIOM. The log view field remains empty until you select one of the three buttons (Read Rate, System Counters, or Message Log). Update Firmware is used to reload the reader firmware.
AXIOM Monitor Status indicators and vital statistics appear on a single screen, enabling you to effectively and efficiently detect and troubleshoot any problems that may occur in high-speed laser bar code scanning.
Accu-Sort Systems, Inc.
08-AXIOM-AXIOM-X_Troubleshooting_R10.doc
Page 145
AXIOM™ / AXIOM-X™ Product Line Manual
Troubleshooting
Status LEDs These AXIOM Monitor status indicators reflect the AXIOM control panel LEDs functionality as well as additional LEDs such as the Match and I/O LEDs. Status LED Definitions LED Conditions Status Green Red Trigger Green
Definition of Conditions
Indicates the overall “health” of the reader. Fault condition: Troubleshooting is required. Indicates the trigger input. The LED is activated upon trigger input regardless of trigger source (including software trigger).
Good/No read Green Indicates a good (valid) bar code has been decoded. Red Indicates a no-read (or incomplete decode). Multiple codes Red Indicates more codes than desired were read. Match Green Indicates a code matches the Match Code criteria. Network (See table below.) Flashes green or red to indicate connection status. Example: A red Network LED upon power up could indicate the MAC address was not set at the factory). ƒ For a Single TCP/IP connection, it indicates that a "host" connection has been made to the reader. ƒ
For EtherNet/IP connection, it indicates "network" connection status. This LED is software controlled.
ƒ
For Controller/Client multi-reader connections, it indicates all inter-reader communications (i.e., connections between readers) are correctly functioning. I/O #1 through I/O #4 Green Indicates the status of the programmable I/O lines.
Network LED during Normal Operations Mode Single TCP/IP
Description Solid green – AXIOM connected to a host. NOTE: If both Host 1 and Host 2 are used, the LED will be solid green if either port is connected. Off – No host connection. NOTE: If UDP messaging is used (unconnected messages) the Network LED will be off. EtherNet/IP Solid green – AXIOM made a connection to the PLC Flashing green – No connection made with the network Flashing red – Lost network connection Controller/Client Controller Solid green – The correct number of client(s) with the same group number have been found. Flashes red – All client(s) with the same group number have NOT been found Client Solid green – Connected to controller with same group number. Off – Not connected to controller with same group number. NOTE: The mode indicated by the Network LED is dependent on the AXIOM configuration you are using. Ethernet/IP is the highest priority, Single TCP/IP mode operation is the lowest.
08-AXIOM-AXIOM-X_Troubleshooting_R10.doc
Accu-Sort Systems, Inc.
145
Page 146
146
AXIOM™ / AXIOM-X™ Product Line Manual
Troubleshooting
Read Quality The Read Quality indicators provide information regarding the bar code that was read. Read Quality Graph 0-100
Scans/Code Code Position (slider) Code Quality (QQ) Laser 1 through 4
Definition The large percentage bar maps to the values displayed on the reader bargraph. It is a measure of “how well” the bar code was read. Indicates how many passes of the laser (scan lines) contributed to the reading of the code. Indicates the bar code’s position in the AXIOM’s scan line (from zero to 4095). Indicates the QQ (code quality) value for each laser that read the bar code.
Box Information The availability of diagnostic information within these fields depends on whether tracking is enabled or not. The first three are only available in tracking and the last one only in triggered, non-tracking modes. These items are only updated when a trigger occurs. To monitor belt speed more accurately, it can also be viewed as part of the System Counters in the log viewer. Box Information Belt Speed (FPM) Box Length (inch) Code Position (inch) Scans/Trigger
Definition Belt/conveyance speed in feet per minute Box/package length in inches Bar code position on the box in inches Number of scans per trigger cycle
Messages Diagnostic messages from the reader are displayed here. This is primarily information on each bar code read. By right clicking on this area, options for clearing, starting, stopping and logging this information are made available. Message Monitor The message monitor can be used to monitor the messages being sent from any of the reader host ports (either serial or network). As with messages, options for clearing, starting, stopping and logging this information are made available by right clicking. Message Monitor (Display Field) None Com Port #1 Com Port #2 Net Host #1 Net Host #2
Accu-Sort Systems, Inc.
Definition Displays the message transmitted Select the port to be monitored. The AXIOM will not attempt to send messages out Net Host ports unless a connection is already established. Note: Nothing is displayed on Net Host #1 if EtherNet/IP communications are being used.
08-AXIOM-AXIOM-X_Troubleshooting_R10.doc
Page 147
AXIOM™ / AXIOM-X™ Product Line Manual
Troubleshooting
Log Viewer The Diagnostics > Log Viewer lets you review the performance logs saved by the AXIOM. The log view field remains empty until you select one of the three most common logs (Read Rate, System Counters, or Message Log) via the buttons or enter a log request in the Command field. NOTE: Use the Tools > Save LogView to File menu selection to save the on-screen log view information to a file on your PC. This is useful if you need to archive or review the log information at a later time.
Log Viewer Commands There are several commands that you can use to display AXIOM parameters and diagnostic information. Commands can be sent from the Command field on the log viewer. Commands may also be sent from a terminal interface, such as a TELNET connection to the AXIOM. Display Commands DISP COUNTERS DISP ENET DISP LASERS DISP LASERx DISP MSGLOG DISP READRATE Other Commands CLEAR ALL
Description Display the System Counter log view. Display the Ethernet interface status including MAC address. Display ALL Lasers log view. Display one Laser log view, where X is 1 – 4. Display the Message log view. Display the Read Rate log view. Description Clears all information from the Message Monitor.
NOTE: All commands can be issued from the Command field. However, when entering a command in the field, spaces are NOT permitted. As a result, the display commands need to be entered without a space (i.e., DISPCOUNTERS, DISPMSGLOG, etc.) NOTE: Right-click on log view provides two options: Save LogView to File (also available from Tools) and Copy to Clipboard.
08-AXIOM-AXIOM-X_Troubleshooting_R10.doc
Accu-Sort Systems, Inc.
147
Page 148
148
AXIOM™ / AXIOM-X™ Product Line Manual
Troubleshooting
Read Rate Log View For a summary of the AXIOM’s overall performance, click the Read Rate button. You can also enter DISPREADRATE in the command field and click Send.
The Read Rate Log Viewer provides information on the overall read rate. Overall Read Rate Counters Read Rate Total Boxes Good Boxes
Partial Boxes
Bad Boxes
Accu-Sort Systems, Inc.
Description Total number of triggers. A good box is a box with all required codes. This counter is the number of good boxes along with the percentage of the total boxes that were good. A partial box is a box were some, but not all required codes were read. This obviously only applies when the AXIOM is configured to read multiple codes each trigger. A bad box is a box where no codes were read.
08-AXIOM-AXIOM-X_Troubleshooting_R10.doc