Page 131

AXIOM™ / AXIOM-X™ Product Line Manual

Maintenance

7 Maintenance This chapter provides instructions for maintaining optimum performance and life for your AXIOM / AXIOM-X. It provides specific information on: ƒ

Maintenance Procedures

ƒ

Exterior Cleaning

ƒ

Mounting Hardware Checks

ƒ

Wiring Connection Checks

Tools and Materials Required Item

Description

Soft-bristle brush

For cleaning the reader’s exterior

Clean soft cloths

For cleaning the reader’s exterior

Cleaning solutions

Mild detergent solution for cleaning the reader’s exterior. 70% denatured alcohol, 30% de-ionized water solution for cleaning exit window

Soft cotton swabs or lint-free cloth

07-AXIOM-AXIOM-X_Maintenance_R10.doc

Use to clean reader’s exit window

Accu-Sort Systems, Inc.

131

Page 132

132

AXIOM™ / AXIOM-X™ Product Line Manual

Maintenance

Laser Shutoff Procedure In order to perform certain maintenance and service tasks, the reader’s lasers must be shut off in order to comply with all laser safety requirements.

To shutoff the lasers: 1. Press the Test/Diagnostics button for five (5) seconds. 2. The bar graph LEDs will light red for the five (5) second duration and then go out. 3. The lasers will then shut off. 4. After maintenance or service is complete, repeat the process to turn the lasers back on.

Test/Diagnostics button used for Laser Shutoff

AXIOM Button and LEDs involved with Laser Shutoff

Bar Graph LEDs Test/Diagnostics button used for Laser Shutoff

AXIOM-X Button and LEDs involved with Laser Shutoff

Accu-Sort Systems, Inc.

07-AXIOM-AXIOM-X_Maintenance_R10.doc

Page 133

AXIOM™ / AXIOM-X™ Product Line Manual

Maintenance

Maintenance Tasks Perform the maintenance tasks on an “as needed” basis to assure proper operation of the AXIOM / AXIOM-X. Task schedule frequency depends upon the application environment conditions. It only requires a few minutes to complete each maintenance task.

Exterior Cleaning WARNING: Shut down the reader before performing this maintenance task. Do not stare into the reader’s exit window at the laser light. Avoid direct eye exposure. The laser light level does not constitute a health hazard, however staring at the laser light for prolonged periods could result in eye damage. CAUTION: Do not use any chemical on the reader that is unsafe for plastics, such as benzene, acetone, or similar products. Before performing this maintenance task, be sure to shutdown the reader.

The exterior cleaning procedure may be performed without removing the reader from the mounting structure. 1. Turn off the reader’s lasers. (See Laser Shutdown, page 132.) 2. Clean the exterior (except the exit window) with a clean, soft-bristle brush. Be sure not to brush any dust, dirt, or debris onto the exit window. 3. Carefully remove any debris in or around the exit window. 4. Wipe the exterior (except the exit window) with a clean, soft cloth dampened slightly with a mild detergent solution. 5. The exit window should be cleaned after this task is completed. (See Cleaning the Exit Window.)

07-AXIOM-AXIOM-X_Maintenance_R10.doc

Accu-Sort Systems, Inc.

133

Page 134

134

AXIOM™ / AXIOM-X™ Product Line Manual

Maintenance

Cleaning the Exit Window WARNING: Shut down the reader before performing this maintenance task. Do not stare into the exit window at the laser light. Avoid direct eye exposure. The laser light level does not constitute a health hazard, however staring at the laser light for prolonged periods could result in eye damage. CAUTION: Never apply cleaning solution directly to the exit window. Always apply the solution to a cloth, and then the cloth to the window. Do not use any chemical on the reader that is unsafe for plastics, such as benzene, acetone, or similar products.

The exit window cleaning procedure may be performed without removing the reader from the mounting structure if it is possible to do so. 1. Turn off the reader’s lasers. (See Laser Shutoff.) 2. Follow the exterior cleaning procedure before cleaning the exit window. 3. Check the exit window surface for any dust, dirt, or smudges. If the window needs to be cleaned, proceed to Step 4. 4. Make a solution of seven parts denatured alcohol and three parts water. 5. Apply the cleaning solution to a cotton swab or lint-free cloth. 6. Apply the cleaning solution to the exit window. 7. Remove any streaks or remaining moisture from the exit window with a dry, soft, lint-free cloth or lens paper. 8. Turn the reader’s lasers back on. 9. Verify reader operation. Follow the Operations Checklist procedure in Chapter 5.

AXIOM

AXIOM-X

Accu-Sort Systems, Inc.

07-AXIOM-AXIOM-X_Maintenance_R10.doc

Page 135

AXIOM™ / AXIOM-X™ Product Line Manual

Maintenance

Cleaning the Trigger Photoeye If your application uses the photoeye option as a hardware trigger, be sure to clean the photoeye periodically as outlined below. 1. Turn off the product transport. 2. Turn off the reader’s lasers. (See Laser Shutoff.) 3. Clean the photoeye’s lens using the denatured alcohol solution and a cotton swab or lens paper. 4. Check the reflector on the opposite side of the transport. Clean as necessary. 5. Verify photoeye operation.

Verify Trigger Photoeye Operation 1. Block the photoeye to confirm it is aligned properly with the reflector. 2. If the LED on the photoeye changes status, the photoeye is functioning properly.

3. Verify that the Trigger LED on reader is green when photoeye is blocked. 4. If the photoeye’s LED does not change status, adjust the photoeye so that it is properly aligned with the reflector. 5. If the Trigger LED on the reader is not green when the photoeye is blocked, check the cabling between the photoeye and reader wiring base for damage. NOTE: The Height Tracking Photoeyes should also be maintained using these procedures.

07-AXIOM-AXIOM-X_Maintenance_R10.doc

Accu-Sort Systems, Inc.

135

Page 136

136

AXIOM™ / AXIOM-X™ Product Line Manual

Maintenance

Cleaning the Tachometer If your application uses the tachometer option for tracking purposes, be sure to clean the tachometer wheels periodically as outlined below. 1. Turn off the product transport. 2. Turn off the reader’s lasers. (See Laser Shutoff.) 3. Using a clean, soft cloth, wipe the wheels of the tachometer clean using a mild detergent solution. 4. Before restarting the system, be sure the tachometer is making good contact with the product transport. 5. Verify tachometer operation.

Verify Tachometer Operation There are two ways to verify tachometer operations. Use AXCESS Setup Software 1. Connect reader to a computer. 1. Start the AXCESS setup software. 2. Go to Diagnostics > AXIOM Monitor. 3. Verify the Belt Speed is accurate when the conveyor is running. Use Tach LED in Wiring Base 1. Remove the scan head from the wiring base.

2. Slowly spin the tachometer wheel while verifying the tach LED in the wiring base is flashing.

Accu-Sort Systems, Inc.

07-AXIOM-AXIOM-X_Maintenance_R10.doc

Page 137

AXIOM™ / AXIOM-X™ Product Line Manual

Maintenance

Tighten Mounting Hardware 1. Check all reader mounting hardware. DO NOT disturb the reader’s alignment as it relates to the product transport. 2. Check the mounting hardware of the photoeye and tachometer (if these options are being used). 3. Tighten as necessary. Do not over-tighten.

Checking Wiring Base Connections All wiring connections to the reader are made through the wiring base. Specific wiring instructions are located on the insulation flap inside the wiring base. (See Chapter 4.) 1. Check all wiring connections to the wiring base terminal blocks. 2. Tighten as necessary. Do not over-tighten. 3. Check all cabling/conduit for signs of wear/damage. 4. Repair/replace any damaged cable connections as necessary.

Verify Reader Operation 1. Follow the Operations Checklist procedure defined in Chapter 5. 2. If the reader parameters were changed to read bar codes other than the factory defaults, simply use a good quality bar code to assist in verifying proper operations. There is no need to return the reader to the default parameters to perform this test.

07-AXIOM-AXIOM-X_Maintenance_R10.doc

Accu-Sort Systems, Inc.

137

Page 138

138

Maintenance

AXIOM™ / AXIOM-X™ Product Line Manual

Notes:

Accu-Sort Systems, Inc.

07-AXIOM-AXIOM-X_Maintenance_R10.doc