Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 15 of 26

AXIOM / AXIOM-X Product Line Manual: Chapter 6: Operations

Pages 117 to 130 of 230, from AXIOM / AXIOM-X Product Line Manual

The original document is the PDF (7.2 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Accu-Sort Axiom 400 and Accu-Sort Axiom-X

Page 117

AXIOM™ / AXIOM-X™ Product Line Manual

Operations

6 Operations This chapter provides details on how the AXIOM / AXIOM-X bar code scanning solutions function during normal operation. It also outlines how you can verify optimal performance through several methods: ƒ

Become more familiar with your application

ƒ

Step-by-step start-up operations checklist

ƒ

Status Indicator LEDs

ƒ

Diagnostics to confirm normal operations (using AXCESS)

After configuring your reader with the AXCESS for AXIOM Setup Software, use the operations checklist to verify normal operations. (See Chapter 5.)

First-time Startup On initial power-up, the AXIOM performs a series of self-diagnostic and LED tests. The complete power-up sequence takes about 30 seconds. When the STATUS LED flashes and turns a steady green the power-up sequence is complete. The AXIOM is now operational. NOTE: When an application uses multiple AXIOM readers, you can provide each reader with a unique reader name using the AXCESS setup software. This makes it easier to keep track of reader parameter changes when working with several readers on a network. (See Chapter 5.)

Default Parameters The reader is shipped from the factory with these defaults: ƒ

Connection Mode: Setup Cable

ƒ

Reader Name: AXIOM

ƒ

Control Panel Buttons Enabled

ƒ

Code 128 (10-30 characters)

ƒ

IP address 192.0.0.100

Perform the following setup procedure using these defaults or configure your AXIOM with your application’s parameters using the AXCESS Setup Software.

06-AXIOM-AXIOM-X_Operations_R10.doc

Accu-Sort Systems, Inc.

117

Page 118

118

AXIOM™ / AXIOM-X™ Product Line Manual

Operations

First-time Setup AXCESS Setup Software for AXIOM, functioning under the familiar Windows® operating system on your computer, is the tool you will use to define operating parameters, set bar code type / length, and construct output messages, including filtering, stripping and padding capabilities. AXCESS enables you to easily configure, fine-tune, and monitor your reader’s operations, allowing you to program it to fit your application seamlessly. AXCESS provides ease-of-use regardless of your experience with bar code readers. A beginner follows basic setup procedures for a standard configuration. If you are more experienced, use the advanced setup features that allow access to more complex options. In either case, the user-friendly AXCESS Wizard efficiently guides you through a sequence of screens until the reader is configured to fit your application. To setup your AXIOM / AXIOM-X bar code reader: 1. Install AXCESS on the computer you will use to setup your reader. 2. Connect the programming setup cable to the reader’s setup port. 3. Connect the programming setup cable to your computer. 4. Apply power to the reader. 5. Set configuration parameters using AXCESS for bar code symbologies, trigger, tracking, and communications (serial, Ethernet, and I/O). (See Chapter 5.) 6. Check operations using the Test Mode.

Check Operations using Test Mode NOTE: Perform the following test using a bar code that matches the default parameters. You can also perform this test after configuring the AXIOM to your specifications. If the default parameters have been changed, you must enable the control panel buttons and the other default parameters listed. See Modify > AXIOM Configuration and Modify > Bar Code Setup. To quickly check AXIOM operation: 1. Apply power to the reader. 2. Position a test bar code symbol approximately 20 inches [508 mm] from the reader. Skew the bar code symbol slightly. 3. Press the Test/Diagnostics button on the control panel to initiate test. 4. The laser(s) should be scanning continuously during normal operations. (Observe the laser safety warnings in Chapter 2. If it becomes necessary to shutoff the laser(s), follow procedure outlined in Chapter 7.) 5. Observe the bar graph LEDs on the AXIOM-X control panel. The bar graph LEDs illuminate when the reader is scanning and decoding the bar code symbol. (See page 120.)

Accu-Sort Systems, Inc.

06-AXIOM-AXIOM-X_Operations_R10.doc

Page 119

AXIOM™ / AXIOM-X™ Product Line Manual

Operations

6. Using the programming setup cable, connect your PC to the setup connector on the wiring base. You may also connect via a network. 7. Run the AXCESS setup software and establish a connection with the reader. 8. Using AXCESS Explorer, go to the Diagnostics > AXIOM Monitor. 9. During operations, use the AXIOM Monitor to confirm the reader’s status, read quality, code quality, and messages via the on-screen indicators. (See Chapter 8, Diagnostics.) 10. Close the connection to the reader. 11. Disconnect setup cable.

Operations Checklist

06-AXIOM-AXIOM-X_Operations_R10.doc

ƒ

Check trigger photoeye LED for proper operation.

ƒ

Test parameters to assure optimal operation.

ƒ

Observe the reader’s Status Indicator LEDs during power-up. (What to watch for is outlined later in this chapter.)

ƒ

Using AXCESS Explorer, select Diagnostics > AXIOM Monitor. (See Chapter 5.)

ƒ

Pass test label in scanning beam.

ƒ

Adjust mounting as needed for optimal performance.

ƒ

Modify parameters as needed for optimal performance.

ƒ

Save parameters to scan head.

ƒ

Backup parameters from scan head to wiring base.

ƒ

Backup parameters to disk (optional, but recommended).

Accu-Sort Systems, Inc.

119

Page 120

120

Operations

AXIOM™ / AXIOM-X™ Product Line Manual

Control Panel Status Indicators There are several control panel status indicators on the AXIOM / AXIOM-X.

AXIOM Control Panel (on scan head)

AXIOM-X Control Panel (on scan head)

Accu-Sort Systems, Inc.

06-AXIOM-AXIOM-X_Operations_R10.doc

Page 121

AXIOM™ / AXIOM-X™ Product Line Manual

Operations

The LEDs provide the following indications during normal operations. Using LED Indicators to Check Normal Operations

06-AXIOM-AXIOM-X_Operations_R10.doc

LED

Description

STATUS

GREEN to indicate the overall "health" of the reader. (If RED, see Chapter 8, Troubleshooting.)

TRIGGER

Indicates the trigger input. The LED is activated upon trigger input regardless of trigger source (incl. software trigger).

READ

Flashes red or green based upon the software criteria.

RX/TX

LED for serial port 1.

NETWORK

Flashes red or green to indicate connection status.

GREEN = Transmitting data RED = Receiving data

ƒ

For a Single TCP/IP connection, it indicates that a "host" connection has been made to the reader.

ƒ

For EtherNet/IP connection, it indicates "network" connection status. This LED is software controlled.

ƒ

For a Controller/Client multi-reader connection, it indicates that all inter-reader communications (connections between readers) are correctly functioning.

LINK

This LED is LINK indicator for Ethernet. Flashes GREEN when connected to a network.

Bar Graph (LED 1 - 5)

ƒ

Scan quality indicator.

ƒ

Flashes when parameters copied to/from wiring base.

ƒ

LEDs stay on when Test/Diagnostic button C is pressed during the laser shutoff procedure. (See Chapter 7, Maintenance.)

Accu-Sort Systems, Inc.

121

Page 122

122

AXIOM™ / AXIOM-X™ Product Line Manual

Operations

NETWORK LED during Normal Operations Mode Single TCP/IP

Description Solid GREEN – AXIOM-X connected to a host. NOTE: If both Host 1 and Host 2 are used, the LED will be solid GREEN if either port is connected. Off – No host connection. NOTE: If UDP messaging is used (unconnected messages) the Network LED will be off. EtherNet/IP Solid GREEN – AXIOM-X made a connection to the PLC Flashing GREEN – No connection made with the network Flashing RED – Lost network connection Controller/Client Controller Solid GREEN – The correct number of client(s) with the same group number have been found. Flashing RED – All the client(s) with the same group number have NOT been found Client Solid GREEN – Connected to a controller with the same group number. Off – Not connected to a controller with the same group number. NOTE: The mode indicated by the Network LED is dependent on the configuration you are using. Ethernet/IP is the highest priority, Single TCP/IP mode operation is the lowest.

Using Control Panel Buttons to Check Normal Operations Ref A

Button

Description

Restore to AXIOM

Restores parameters from Wiring Base to Scan Head ƒ Button must be pressed twice to initiate action. ƒ See page 123 for procedure.

B

Backup to Base

Downloads parameters from Scan Head to Wiring Base ƒ Button must be pressed twice to initiate action. ƒ See page 123 for procedure.

C

Test /Diagnostic (Laser Shutoff)

ƒ Enables the AXIOM-X test mode. (Test mode can also be selected remotely using AXCESS Tools > AXIOM Commands > Test Mode.) ƒ Use to perform laser shutoff. (See page 132.)

REMEMBER: The reader’s control panel buttons can be enabled or disabled through the use of the AXCESS setup software. (See Modify > AXIOM Configuration, Enable AXIOM Control Panel Buttons.)

Accu-Sort Systems, Inc.

06-AXIOM-AXIOM-X_Operations_R10.doc

Page 123

AXIOM™ / AXIOM-X™ Product Line Manual

Operations

Backup / Restore Procedures To backup parameters from scan head to wiring base: 1. Press the backup button for about 1 second. 2. Release button. The bar graph LEDs continuously flash to indicate the button has been pressed long enough. If the LEDs flash only once, the button was not pressed long enough. 3. Press button a second time while LEDs are flashing. Hold for about 1 second. 4. Release button. The bar graph LEDs strobe from 5 to 1 indicating parameters are being backed up from scan head to wiring base. 5. When the LEDs stop strobing, the backup is complete. To restore parameters from wiring base to scan head: 1. Press the restore button for about 1 second. 2. Release button. The bar graph LEDs continuously flash to indicate the button has been pressed long enough. If the LEDs flash only once, the button was not pressed long enough. 3. Press button a second time while LEDs are flashing. Hold for about 1 second. 4. Release button. The bar graph LEDs strobe from 1 to 5 indicating parameters are being uploaded from wiring base to scan head. 5. When the LEDs stop strobing, the upload is complete. Restore

Backup

AXIOM

Restore

Backup

AXIOM-X

06-AXIOM-AXIOM-X_Operations_R10.doc

Accu-Sort Systems, Inc.

123

Page 124

124

Operations

AXIOM™ / AXIOM-X™ Product Line Manual

Checking Operations with AXCESS The AXCESS Diagnostics > AXIOM Monitor enables you to evaluate the operational performance of your reader by providing vital statistics via status indicators, real-time read quality monitoring, and box information. Outgoing and incoming messages are also monitored.

Accu-Sort Systems, Inc.

06-AXIOM-AXIOM-X_Operations_R10.doc

Page 125

AXIOM™ / AXIOM-X™ Product Line Manual

Operations

Checking Multi-Reader Network with AXCESS From the AXIOM Controller, check Diagnostics > Log Viewer > Read Rate. This simple diagnostic allows you to check bar codes read, by laser, for each Client in the network. Each client is identified in the Read Rate Log by the unique name and IP address assigned to it using AXCESS. (See Chapter 5.)

06-AXIOM-AXIOM-X_Operations_R10.doc

Accu-Sort Systems, Inc.

125

Page 126

126

AXIOM™ / AXIOM-X™ Product Line Manual

Operations

Standalone Operation In a typical standalone setup, a single AXIOM / AXIOM-X scans bar codes on one side of packages as they move down a conveyor. A photoeye is used to trigger the reader to begin searching for valid bar codes. Bar code data is transmitted to a host device.

A simplified schematic diagram of the required items is shown below: AXIOM / AXIOM-X S can Head P hotoeye

1 2 AXIOM Wi ring Base 3 4

Programmi ng Cable

Network/Host Communications

PC

Universal Mounting Bracket AC Power Power Supply

Accu-Sort Systems, Inc.

06-AXIOM-AXIOM-X_Operations_R10.doc

Page 127

AXIOM™ / AXIOM-X™ Product Line Manual

Operations

Tracking Operation By utilizing the tracking capabilities of the AXIOM, you can configure your application to monitor the progress of packages on the conveyance system. Tracking enables the reader to track bar codes and the packages to which they belong. Your reader may scan more than one package with more than one code at a time within its read zone. Tracking allows the reader to accurately associate the correct bar code(s) with the correct packages. Typical tracking configurations use a tachometer to monitor conveyor speed.

A simplified schematic diagram of the required items for a tracking application is shown below:

P hotoeye Tachometer

AXIOM / A XIOM- X Scan Head 1 2 Wiring Base 3 4

HOS T Serial Communicati ons

HO ST Network Communicati ons Setup PC (A XCESS)

Setup Functions for AXIOM / AXIOM-X Tracking Operation ƒ

Modify > Tracking – Tachometer (define tach type)

ƒ

Modify > Tracking – AXIOM Mounting

ƒ

Modify > Tracking – Transmit

ƒ

Modify > Tracking – Track Config

Basic Tracking Setup Procedure To assure tracking accuracy, the distance from the Trigger Photoeye to the “X” scanning pattern must be measured and entered in AXCESS. 1. To properly track-in the reader, drop a plumb bob from the center of the AS logo on the scan head. 2. Measure the distance (in inches) from the plumb bob to Trigger Photoeye. 3. Use AXCESS to establish a connection with the reader. 4. Enter the value (in inches) into the Modify > Tracking > AXIOM Mounting > Trigger Reference Point field. IMPORTANT: After completing the basic tracking setup, see the advanced tracking procedure provided in the Modify > Tracking section. The Tracking > Trigger Reference Point, Closest Read Point and Furthest Read Point parameters must be properly set. (See Chapter 5.)

06-AXIOM-AXIOM-X_Operations_R10.doc

Accu-Sort Systems, Inc.

127

Page 128

128

AXIOM™ / AXIOM-X™ Product Line Manual

Operations

Dual X-Scanning Operation In dual X-scanning applications, two AXIOM-X omnidirectional readers mounted side-by-side are used to create a dual “X” scanning patterns across the entire width of a conveyor.

Dual X-pattern can be created by two AXIOM-X (or four AXIOM)

A simplified schematic diagram of the required items for an X-scanning configuration is shown below:

P hotoeye Tachometer

AXIOM-X (Controller)

HOS T Serial Communicati ons

Wiring Base

HOST Network Communications

Ethernet PC

AXIOM-X (Client)

Setup Functions for Controller ƒ

Modify > AXIOM Configuration - Reader Name (Controller)

ƒ

Network Settings - # of Client Readers, IP address, and Group #

Setup Functions for Clients ƒ

Modify > AXIOM Configuration - Reader Name (Client 1,2,3)

ƒ

Network Settings – IP address and Group #

See Chapter 5 for details on setting up a multi-reader network.

Accu-Sort Systems, Inc.

06-AXIOM-AXIOM-X_Operations_R10.doc

Page 129

AXIOM™ / AXIOM-X™ Product Line Manual

Operations

Multiple-Reader Network Operation In multiple-reader applications, from two to six readers can be networked together. A single reader is configured as a Controller for a multiple-reader network. The Controller gathers data from other readers (up to five, configured as clients) over an Ethernet network. The Controller then collects and transfers the collected data over a serial communications or network link to the host.

A simplified schematic diagram of the required items for a multiple-reader configuration is shown below:

P hotoeye

AXIOM (Controller)

HOS T Serial Communicati ons

Wiring Base

HOST Network Communications

Tachometer

AX IOM (Client) PC

Ethernet Sw itch

AX IOM (Client)

AX IOM (Client)

Setup Functions for Controller ƒ

Modify > AXIOM Configuration - Reader Name (Controller)

ƒ

Network Settings - # of Client Readers, IP address, and Group #

Setup Functions for Clients ƒ

Modify > AXIOM Configuration - Reader Name (Client 1,2,3)

ƒ

Network Settings – IP address and Group #

See Chapter 5 for details on setting up a multi-reader network.

06-AXIOM-AXIOM-X_Operations_R10.doc

Accu-Sort Systems, Inc.

129

Page 130

130

AXIOM™ / AXIOM-X™ Product Line Manual

Operations

Scanning Array / Tunnel Operations When two multi-reader AXIOM networks are coupled to function in the same scanning area, the entire application is called a scanning array or tunnel. NOTE: Due to the complexity of these applications, tunnel arrays are typically custom-engineered to your specifications.

Setup Functions for Controller ƒ

Modify > AXIOM Configuration - Reader Name (Controller)

ƒ

Network Settings - # of Client Readers, IP address, and Group #

Setup Functions for Clients ƒ

Modify > AXIOM Configuration - Reader Name (Client 1,2,3,4,5)

ƒ

Network Settings – IP address and Group #

See Chapter 5 for details.

Accu-Sort Systems, Inc.

06-AXIOM-AXIOM-X_Operations_R10.doc