Page 90

90

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

EtherNet/IP Settings EtherNet/IP allows the AXIOM to communicate bar code and I/O data to other EtherNet/IP (EIP) enabled devices on your network. The Modify > EtherNet/IP Settings are only available if EtherNet/IP has been enabled from the Network Settings window. Once enabled, EtherNet/IP Explicit and I/O messaging are enabled. The EtherNet/IP Objects supported by the AXIOM are described in Appendix C.

Accu-Sort Systems, Inc.

05-AXIOM-AXIOM-X_Setup_R10.doc

Page 91

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

EtherNet/IP Settings Selection Bar Code Data

Definition Select ASCII Message to transmit an ASCII bar code message (as defined by the Message Type). The only difference is that the Header and Trailer are omitted from the bar code messages transmitted using EtherNet/IP. When ASCII messages are in use, the Byte Swap ASCII Data selection will swap the high and low byte of data within each 16 bit word. This is useful for processing data on some Programmable Controllers. Select Binary Message to convert bar code data to a “numeric value” and transferred as a 32 bit word. The user can specify the byte ordering of this word. If any non-numeric (not ASCII ‘0’ to ‘9’ or leading or trailing space) characters are contained in the bar code, the numeric value is zero. On-Demand Messaging is a special option for communicating with ControlLogix Controllers. When enabled, you must provide the Controller IP Address, the Slot number of the processor in the Controller and a Tag Name. To use OnDemand messaging, a tag of the same name is then defined on the ControlLogix Controller and every time a bar code is read, the Bar Code object is transferred to the ControlLogix Tag.

05-AXIOM-AXIOM-X_Setup_R10.doc

AXIOM Inputs

When Enable Trigger Inputs is selected, the AXIOM Trigger settings are ignored and the AXIOM is triggered solely by manipulating the Trigger Bit in the Output Word (contained within the AXIOM Assembly and Output Objects).

AXIOM Outputs

The AXIOM Outputs function the same as AXIOM relay outputs, but they manipulate bits within the AXIOM Input Word (contained in the AXIOM Assembly and Input Objects). When defining these outputs, remember to ensure that the duration of these outputs is two or three times longer than the I/O message interval.

Control of AXIOM Relays

The AXIOM can relinquish control of the internal AXIOM relays to another EtherNet/IP device. When this has been done, the AXIOM relays are only controlled by the appropriate bits within the Output Word (contained within the AXIOM Assembly and Output Objects).

Accu-Sort Systems, Inc.

91

Page 92

92

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

Message Definitions (User-defined Messages) Whenever you specify a user-defined message format for either serial port #1 or network settings, Message Definitions become available within the Modify menu. For the serial port, use the Message Definitions – Port #1 window (shown below). For network communications, use the Message Definitions – Net#1 screen. The following provides details on defining the message framing and contents for the serial port and network communications.

Modify > Message Definitions - Port#1 (User defined Message enabled) NOTE: Use the visual keyboard in the Tools drop-down menu to easily create your user-defined messages. Message Framing Selection Header Trailer Seq # Check Include Multi-Bar code in single message Separator Power Up Message

Accu-Sort Systems, Inc.

Definition Character string specified for the header. Sent at beginning of every message. Character string specified for the trailer. Use to terminate every message. When enabled, a sequence number consisting of the specified number of digits is inserted just after the header. When enabled, a two-character hexadecimal check character is inserted just prior to the trailer. (Checkbox) This parameter effects how the reader handles multiple bar code transmissions. If enabled, the bar codes are sent in one message (between one header and trailer) and each bar code is separated by the specified “separator.” If disabled, all bar codes are always sent as a complete message (with a header and trailer). String used to separate multiple bar codes (see above). String that is always sent on reader initialization. Note that for a Network connection, this string is always sent when the socket connection is made.

05-AXIOM-AXIOM-X_Setup_R10.doc

Page 93

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

Message Content The message drop-down lists define the message options for each bar code. The message content can be defined for transmissions from the AXIOM’s serial port #1 as well as any network connection (via Net#1). These messages are based on various conditions. For each condition, there are options for what message can be sent. These options include: Send Bar Code – Bar code (with padding and/or stripping) is sent. Repeated Character – Send a message consisting of the specified character repeated for the minimum number of characters for the bar code (example is “???????” no-read message). User Specified Message – Send a message defined string for this condition. User Defined Message Content Selection Definition Category #1: These first three conditions are mutually exclusive, so only one of these three messages can be sent for any bar code. Read If “No Message” is selected, nothing is sent for a valid read; otherwise either the bar code or a user-specified message is sent. No Read If “No Message” is selected, nothing is sent for a no-read; otherwise either the specified “repeated character” or the user specified message is sent. Multiple Bar Code If “No Message” is selected, a multiple bar code condition will be reported as a “Read” of the first bar code reported. Otherwise, the specified “repeated character” or the userspecified message is sent. Category #2: The next three conditions are IN ADDITION to the conditions specified above. If a condition in both categories is met, these messages will be appended. If you desire to only generate a message based on these conditions, all messages in Category #1 should be disabled. Match If the bar code matches any of the match codes, this message is sent. Options include sending the bar code or a user specified message. No Match If the bar code does not match any of the match codes (or was a no-read), this message is sent. Options include sending a “repeated character” or a user specified message. No Match Read If a valid bar code was read, but it does not match any of the match code, this message is sent. Options include sending the bar code or a user specified message. Append QQ (code quality) to message (checkbox) Heart Beat Message

Heart Beat Time Out (0-30,000 ms)

05-AXIOM-AXIOM-X_Setup_R10.doc

When selected a two digit “code quality” indication (number from 00 to 99) is appended to the bar code message. The code quality value is separated from the message with the specified separator. When enabled, if no other message is sent for the specified period of time, the specified heart beat message string is sent. (A time-out of zero disables this option.) 0 = Disable Heart Beat message 1-30,000 = Delay before sending Heart Beat message

Accu-Sort Systems, Inc.

93

Page 94

94

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

Trigger and Relay Settings Use the Modify > Trigger and Relay Settings window to set the type of trigger. It also provides configurations for the optional input/output relay modules.

Example: IO Configuration when Height Tracking Photoeyes are used.

Trigger Source The trigger source options are: ƒ Hardware Trigger ƒ Hardware Start/End Trigger ƒ Software Trigger ƒ Continuous Trigger Since the trigger parameters vary based on trigger type selected, the trigger parameter options are defined within the context of the specific trigger source.

Accu-Sort Systems, Inc.

05-AXIOM-AXIOM-X_Setup_R10.doc

Page 95

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

Trigger Source Options Selection Hardware Trigger Active-High vs. Active-Low Debounce Duration (ms) Transmit Delay (ms) (only for Transmit after End Trigger)

Definition

This defines whether trigger is active when the input signal is high or low. Defines the minimum time required for detection of a change in the hardware trigger status. This defines how long after the end of trigger this code will be sent. If Transmit Delay is set to zero, the code will be transmitted once all scan data has been processed. Otherwise, the reader will not transmit the code until the transmit delay period is over. Transmit Type Defines when the bar code(s) should be transmitted. Transmit after End Trigger - No codes will be transmitted until after the end of the trigger signal. Transmit after Code Read - Codes will be transmitted as soon as they are decoded. Trigger Timeout This defines a period of time after which trigger will be (ms) automatically terminated. If set to zero, automatic (only for Transmit termination of trigger is not performed. after Code Read) (This appears in place of Transmit Delay.) Hardware Start/End Trigger This defines whether trigger is active when the input signal Active-High is high or low. In this case this needs to be specified for vs. BOTH the hardware trigger input (which is used for start Active-Low trigger) and for IO#1 which is used for the end trigger input. NOTE: Typically these parameters are set to OPPOSITE values as the end trigger signal (IO#1) indicates the state at which trigger should be stopped. Transmit Delay This defines how long after the end of trigger this code will be sent. If Transmit Delay is set to zero, the code will be transmitted once all scan data has been processed. Otherwise, the reader will not transmit the code until the transmit delay period is over. Software Trigger Port Selection Defines the source of the software trigger message. It can be any “host port” either serial or network based (i.e., Host 1,2 or Net 1,2). Although shown, Host-2 is not available. Start Character / These define the ASCII characters that, when received, will End Character start and end trigger of the reader. Transmit Delay (ms) This defines how long after the end of trigger this code will be sent. If Transmit Delay is set to zero, the code will be transmitted once all scan data has been processed. Otherwise, the reader will not transmit the code until the transmit delay period is over. Continuous Trigger Continuous Reader is always in trigger and transmits any bar codes that are seen. Timed Whenever a code is transmitted, trigger is removed for the period of time specified in Trigger Off-Time. Once Same as continuous, but the same bar code will not be sent a second time until the Bar Code Time Out value has expired.

05-AXIOM-AXIOM-X_Setup_R10.doc

Accu-Sort Systems, Inc.

95

Page 96

96

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

I/O Options Outputs are the most common uses for the I/O options (e.g., use to activate diverters, beacon lights, alarms, etc. when specific conditions occur). The only input options are to indicate an end trigger or custom signals. Input Custom Input End Trigger

Learn Match Code

Height Tracking Photoeye

Definition User-defined signal sent to AXIOM (requires custom software) Only available at I/O#1 if the Trigger Source is set to Hardware Start/End Trigger. Active when trigger signal ends (i.e., photoeye no longer blocked). When this input is active, the AXIOM is placed into Test Mode in order to “learn” a match code. When the line is deactivated, Test Mode is exited. When this option is enabled, the last code read is stored in the first entry of the Match Table. Used in applications requiring Height Tracking Photoeyes. Up to three photoeyes may be used to divide the AXIOM’s depth of field into up to four zones. The Distance from scanner (in inches) must also be set. (See Chapter 3. See Mounting the Height Tracking Photoeyes.) CAUTION: If you get this message when saving parameters, they should be corrected before saving them.

CAUTION: If you get this message when retrieving parameters, you should correct and save them before use.

Output Custom Output Life Light Trigger Output Error Light Good Read Output No-Read Output Match Output No Match Output Good Read and NoMatch Output Multiple Output Multiple or NoRead Output

Accu-Sort Systems, Inc.

Definition Used for applications involving custom software to select a customized output option. Always on while the reader is operating. Echoes the status of the trigger signal. Active in the event of an error condition (see later section on errors currently detected). Active if all expected codes are read. Active if not all expected codes are read. Active if any code matches the match code criteria. Active if no codes match the match code criteria (includes no-reads). Active if a code was read but did not match the match code criteria. Active is too many codes were read. Active if too many codes were read or a no-read occurred.

05-AXIOM-AXIOM-X_Setup_R10.doc

Page 97

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

Tracking Use the Modify > Tracking window to define the parameters associated with monitoring package travel on the conveyance system. The tracking parameters are only available if tracking is enabled; otherwise they are not shown in this window. Click the Tracking Enabled checkbox. When tracking is enabled, a checkmark appears in the checkbox and the tracking parameter settings are visible in the window.

The tracking options for the tachometer are: ƒ Hardware/External Tach ƒ Constant/Internal Tach ƒ Computed Tach NOTE: Details on tracking applications are provided in Chapter 6.

05-AXIOM-AXIOM-X_Setup_R10.doc

Accu-Sort Systems, Inc.

97

Page 98

98

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

Tachometer Type Settings Drop-down List Hardware/External Tach

Definition Used for external hardware tachometer. User must set the number of pulses per inch generated by the tachometer. User can specify the tach rate to be used (from 25-600 ft/min). There are two options available: Start-End and StartStart. In both cases, the user specifies the Length (from 1-200 inches) between either a start and end trigger (Start-End) or between one start trigger and the next (Start-Start). From this information the reader will compute the belt speed and generate an internal tach signal. Use to set the number of tach pulses per inch of conveyor travel (from 1-16 PPI).

Constant/Internal Tach Computed Tach

Pulses per inch (slider)

Transmit Point Settings Selection Transmit Edge Transmit Point (in.)

Definition Specifies which edge of the package (leading or trailing) is used to determine the transmit point. The point at which bar code data is transmitted. Defines the number of inches after the specified edge of the package passes the trigger before data transmission occurs.

AXIOM Mounting Settings Selection Closest Read Point (in.) Farthest Read Point (in.) Trigger Reference Point AXIOM Rotation Direction (deg.) (slider)

Definition Specify, in inches, the nearest distance from the reader where the reader is expected to read a bar code. Defines the furthest distance from the reader where the reader is expected to read a bar code. Specifies the distance from the trigger signal to the center point of the scan line. Specifies any rotation of the scan line with respect to the motion of the belt. Use the slider to set the rotation direction from -180 to 180 degrees. A scan line that is perpendicular to the belt has a rotation angle of 0. Two readers mounted in an X-pattern have rotation angles of 45 and 135 or -45 and -135 degrees respectively.

Tracking Configuration Settings Selection Extend Front (in.) Extend Back (in.) Tolerance

Accu-Sort Systems, Inc.

Definition Used to increase the apparent size of the package by increasing the leading edge (front) of the package. Used to increase the apparent size of the package by increasing the trailing edge (back) of the package. Specifies the tolerance (in inches) for associating a label with a box.

05-AXIOM-AXIOM-X_Setup_R10.doc