Page 99

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

Tracking Setup Procedures Specify Tachometer Source AXIOM tracking requires a tachometer input that reflects the belt speed. This tachometer input can originate from one of three sources: ƒ ƒ ƒ

Hardware tachometer input Constant tachometer input (generated internal to AXIOM) Computed tachometer input (for first size or evenly spaced packages, the software will compute the belt speed from the package length or spacing)

In all instances, the tachometer configuration can be verified by monitoring “belt speed” on the AXIOM Monitor. The belt speed is displayed in ft/min. Specify Transmit Point All tracking systems, require the transmit point for the bar code to be specified. This is a point, located a fixed number of inches from the trigger source (such as a photoeye), at which the bar code for a package will be transmitted. When assigning the transmit point, make sure the package will have completely passed through the lasers before reaching the transmit point and leave some margin for “processing time” once the bar code has passed through the laser.

05-AXIOM-AXIOM-X_Setup_R10.doc

Accu-Sort Systems, Inc.

99

Page 100

100

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

Specify AXIOM Mounting Information For proper performance, the following information about the reader mounting is required. ƒ ƒ ƒ ƒ

The nearest and furthest distance (from the front window of the AXIOM) at which a bar code is to be read. The distance from the trigger source (i.e., Photoeye) to the center point of the AXIOM scan line (Trigger Reference Point). Orientation of the reader with respect to the motion of the belt. This is a rotation value from 0 to 360 degrees. When an AXIOM reader’s scan line (or AXIOM-X reader’s “X” pattern) is perpendicular to conveyor travel, it has a rotation angle of zero degrees.

AXIOM mounted at zero degrees

AXIOM-X (Omnidirectional) mounted at zero degrees

Accu-Sort Systems, Inc.

05-AXIOM-AXIOM-X_Setup_R10.doc

Page 101

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

AXIOMs (2) in X-pattern configuration When two AXIOM readers are mounted to create an X-pattern, they have rotation angles of 45 and 135 degrees or -45 and -135 degrees respectively. NOTE: This only applies to the use of two AXIOM line scanners; it does not apply to AXIOM-X omnidirectional scanners.

05-AXIOM-AXIOM-X_Setup_R10.doc

Accu-Sort Systems, Inc.

101

Page 102

102

Setup

AXIOM™ / AXIOM-X™ Product Line Manual

Advanced Tracking Setup Procedure To assure tracking accuracy, the Tracking > Trigger Reference Point, Closest Read Point and Farthest Read Point parameters must be properly set to match the application. NOTE: This procedure assumes that the basic setup procedure has already been performed. (See Chapter 6, Tracking Operation.) IMPORTANT: If Height Tracking Photoeyes are used, be sure to disable them before performing the advanced tracking setup procedure. (See Modify > Trigger and Relay Settings. Select the Not in use option.) 1. In AXCESS, go to the Modify > Tracking screen. 2. Set both the Closest Read Point and Farthest Read Point (in inches) to the distance from scanner to bar code. 3. Measure the distance (in inches) from the center of the bar code to the front edge of the package. When the Trigger Reference Point is set correctly, tracking will report this number. NOTE: Make sure that the package position intersects the scan lines so that the bar code will be read as close to the center of the “X” as possible. 4. Select the AXCESS Monitor screen. 5. Run the package through the scanning area. 6. Observe the reported tracking position in the Messages window. For example: The display “Box/Zone/Code:42/1/3” is reporting a bar code position of 3 inches from the front of the package. 7. Adjust the Trigger Reference Point until the bar code position reported in the Messages window is correct. 8. Reset the Closest Read Point and Farthest Read Point parameters as follows: a. Set Closest Read Point to the distance between the scanner and the closest possible bar code that will be read b. Set Farthest Read Point to the distance between the scanner and the furthest possible bar code that will be read c. Once these two read points are set to the actual distance, it is normal for the reported location on the packages to vary slightly. IMPORTANT: If Height Tracking Photoeyes are used, be sure to enable them after completing this procedure. (See Modify > Trigger and Relay Settings. Select the Used as input option.)

Accu-Sort Systems, Inc.

05-AXIOM-AXIOM-X_Setup_R10.doc

Page 103

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

DRX CAUTION: Modifying the DRX features within AXCESS may adversely affect the operation of your AXIOM reader. Changes to the DRX parameters should not be made unless recommended by an authorized Accu-Sort customer support technician. The Modify > DRX settings are only available if Configuration > Setup > Advanced is selected from the drop-down menu.

NOTE: The Modify > DRX parameters are to be modified only under the guidance of Accu-Sort.

Selection Data Filtering

DRX Settings

Transmit QQ

05-AXIOM-AXIOM-X_Setup_R10.doc

Definition The data filtering parameters specify the minimum and maximum pulse width (in counts) for the bar code data. This important data filter setting assures optimal reader performance. The Sampling Frequency default of 100 Mhz assures better decoder resolution for poorly printed bar codes. Scan Filtering (Skip Scans) is disabled for AXIOM-X. The DRX settings typically will not need to be modified. They are very similar to the settings on other Accu-Sort readers. The Minimum QQ is the smallest allowable QQ value for a code to be transmitted. The Maximum QQ forces the transmission of a code after the maximum QQ value is reached.

Accu-Sort Systems, Inc.

103

Page 104

104

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

Save/Retrieve Settings The final step in configuration setup is to Save/Retrieve Settings. Use this window to save all the settings to the scan head. You should also backup your settings to the wiring base and/or disk. This window’s buttons correspond to those in the Toolbar: Both sets of buttons have the same functionality. However, if there is no established connection to a reader, the Toolbar buttons are disabled (grayed), whereas the buttons in this window would display a message indicating there is no connection when selected.

Buttons Save to AXIOM

Retrieve from AXIOM

Save to Disk Retrieve from Disk Default AXIOM Backup to Base Restore from Base

Accu-Sort Systems, Inc.

Definition Use to save parameters from AXCESS to the scan head. Parameters saved on the AXIOM scan head’s parameters storage module are the set of parameters that will be used during normal operations. Retrieves the current parameters from the AXIOM scan head’s parameters storage module to the AXCESS setup software. Use to save a copy of the parameters from AXCESS to disk. Retrieves a set of parameters from disk. Use to return the reader’s parameters to the hardcoded "default" values built-in to the reader software. Use to save a backup copy of the scan head parameters to the wiring base. Retrieves the backup parameters stored in the wiring base. This is especially useful when replacing a scan head module. Use restore from base to load the correct parameters to the replacement head.

05-AXIOM-AXIOM-X_Setup_R10.doc

Page 105

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

Save Parameters to Disk To specify a file name and location to store the current settings, select the Save Parameters to Disk option of the File Drop-down menu. (This function is also found on the Toolbar of AXCESS.) To save setup parameters to disk: 1. Selecting the Save Parameters to Disk function from the File dropdown menu or press <Alt> <F> and <Alt> <V>. This opens the Save parameters to disk window.

2. Locate the folder where the parameters are stored. (The Save parameters window should automatically default to the AXIOM AXCESS folder.) 3. Enter a name for the file in the File name field. The .pam extension is added to the name when you save the file to disk. Be sure to use a unique file name that will aid your memory in case you need to use the file later. 4. Click Save or press the <Alt><S> keys. When this operation is successfully completed, the following message appears in the AXCESS status line: Parameters saved to disk. (If you get a warning message regarding Height Tracking Photoeye parameters, reference Modify > Tracking.) If you have not already done so, be sure to update the wiring base with the file you have saved, using the Backup AXIOM Parameters to Base button. It is recommended that the previous settings and any changes be stored in separate files, in case it becomes necessary to return the reader to a previous configuration. The default file extension for these files, as well as the default folder and directory, is *.pam. NOTE: Parameters can be retrieved from disk only after they have been saved to disk. It is recommended that any changes be stored to a disk file in case you need to return a reader to a previous configuration. It is also a good practice to store any *.pam files in the Parameters folder of the AXCESS directory so that they can easily be located.

05-AXIOM-AXIOM-X_Setup_R10.doc

Accu-Sort Systems, Inc.

105

Page 106

106

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

Retrieve Parameters from Disk Selecting the Retrieve Parameters from Disk function enables you to restore reader settings from a disk file that contains a copy of previously stored reader parameters. (This function is also found on the Toolbar.) To retrieve setup parameters from disk: 1. Select the Retrieve Parameters from Disk function from the File dropdown menu or press <Alt> <F> and <Alt> <R>. This opens the Retrieve Parameters from Disk window.

Retrieve Parameters from Disk 2. Locate the folder where the parameters are stored. (The Retrieve Parameters window should automatically default to the AXCESS folder.) 3. Click the appropriate *.pam file name. 4. Click Open or press the <Alt> <O> key. Once parameters are retrieved, AXCESS is automatically updated to match the retrieved settings. To update the reader with the file you have retrieved, use the Save to AXIOM button. NOTE: If you get a warning message regarding Height Tracking Photoeye parameters, reference Modify > Tracking and Modify > Trigger and Relay Settings. Parameters can be retrieved from disk only after they have been saved to disk. It is recommended that any changes be stored to a disk file (as well as the wiring base), in case you need to return a reader to a previous configuration. (See Save to Disk for details.) The parameters are stored in files with a *.pam extension. NOTE: It is good practice to store any *.pam files in the AXIOM AXCESS folder of the AXCESS directory so that they can be easily located.

Accu-Sort Systems, Inc.

05-AXIOM-AXIOM-X_Setup_R10.doc

Page 107

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

Backup AXIOM Parameters to Base NOTE: The active, or current, parameters used by an AXIOM are stored in the scan head’s parameter storage module. It is recommended that you backup a copy of the parameters to the wiring base’s parameter storage module. By doing so, the current parameters will be available from the wiring base if the need should arise to replace the scan head.

Restore AXIOM Parameters from Base NOTE: This feature is useful if you ever need to replace a scan head or retrieve a set of parameters from the wiring base after modifying the scan head’s parameters only to find that the previous parameters performed better. If you used the Backup AXIOM Parameters to Base earlier, you will be able to recover those parameters from the base using the Restore AXIOM Parameters from Base command.

Exiting AXCESS When you complete your work, you can choose to save or discard any unsaved parameter change(s) before exiting AXCESS. To exit AXCESS: 1. Choose Exit from the File menu. 2. Whether or not you made any changes, AXCESS asks you to confirm your exit. The Exit Setup window is displayed:

3. Choose Yes to exit AXCESS and return to your desktop without saving changes. 4. Choose No to save changes before exiting. This returns you to the active AXCESS window. 5. Use one of the save parameter functions (i.e., Save to AXIOM or Save to Disk), then exit AXCESS.

05-AXIOM-AXIOM-X_Setup_R10.doc

Accu-Sort Systems, Inc.

107