For the Accu-Sort Axiom 400 and Accu-Sort Axiom-X

Page 81

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

Bar Code Groups When more than one bar code type is defined in Bar Code Setup, the Bar Code Groups selection becomes available. This enables you to define the valid “groups” of bar codes that are to be transmitted together.

For example, in the Modify > Bar Code Groups window shown below, the reader is configured to transmit EITHER a code 128 bar code (Group 1) OR both an Interleaved 2 of 5 code and a Code 39 code (Group 2).

Defining a Bar Code Group NOTE: By default, all codes are placed into the same group. To add a code into a group, double-click the empty field in the corresponding group number and code number column. The symbology name would appear from the field. For example: To add Interleaved 2 of 5 to Group 3 in our window shown above, you would double-click the Group 3/Code 2 field. The symbology name would appear in the blank field. To remove a code from a group, double-click the symbology name in that group. The symbology name would disappear from the field. For example: To remove a code from the default group (group 1), doubleclick the symbology name. The symbology name would disappear from the field.

05-AXIOM-AXIOM-X_Setup_R10.doc

Accu-Sort Systems, Inc.

81

Page 82

82

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

User Defined Mod Checks This window becomes available when you specify a user defined mod check for a symbology while in Modify > Bar Code Setup.

Field Factors Divisor: (1-255) Remain

Right Wrap

Add

Accu-Sort Systems, Inc.

Definition Define weighting factors for determining mod check value. Example: Enter 31 for a 3-to-1 weight. Number that is divided into the mod check sum. Defines whether check digit is a remainder of the divided amount or the number that must be added to the remainder to get the divisor. Defines where weight string begins (i.e., from right if selected). If the remainder of the check digit is calculated to be 0, accept 0 as check character (wrap not selected) or replace the 0 with a 1 (wrap selected). Select to add the most significant digit to the mod check.

05-AXIOM-AXIOM-X_Setup_R10.doc

Page 83

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

Bar Code Padding and Stripping For each code type (defined in Bar Code Setup), padding and/or stripping of the bar code data can be specified using the Modify > Bar Code Padding and Stripping screen. This padding and stripping is applied to the bar code before any message formatting.

Character Stripping Option Group Transmit All Strip Selected Characters

Definition Transmits all data Example: To strip the first and last character of a code (such as for Codabar without start and end) specify F1,L1 for the character stripping. NOTE: Stripping is applied before padding.

Character Padding Option Group No Padding Add Padding

Padding Before bar code for fixed length Padding After bar code for fixed length

05-AXIOM-AXIOM-X_Setup_R10.doc

Definition No effect on bar code. This will add a fixed string of characters to the beginning and/or end of the bar code. The character(s) to be added as padding must be entered in the field next to the Add Padding option button. The specified character is repeated before the bar code to create a string of the length specified (30-50). The specified character is repeated after the bar code to create a string of the length specified (30-50).

Accu-Sort Systems, Inc.

83

Page 84

84

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

Match Codes Setup Use the Modify > Match Codes Setup window to define a specific code pattern within a symbology type that is to be considered a “match condition”. In addition to identifying and reading a symbology you defined (using the Modify > Bar Code Setup function), this feature enables you to configure an AXIOM to match specific characters within a bar code.

All bar codes are compared to the complete list of Match Codes. If a bar code matches ANY of the codes defined in Match Code Setup it is considered a MATCH. When a match code is read, you can also setup your AXIOM to: ƒ

Fire a relay - e.g., Activate a diverter

ƒ

Send a user-defined message - e.g., Acknowledge match code

The following wildcards are available: ƒ

“*” represents a string with arbitrary length

ƒ

“?” represents a single character REMEMBER: If ANY match code pattern is set to “*” (i.e., the asterisk wildcard), ALL codes will match it.

Accu-Sort Systems, Inc.

05-AXIOM-AXIOM-X_Setup_R10.doc

Page 85

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

Serial Communications Port#1 Use the Modify > Serial Communications Port#1 window to set the serial port connection parameters (e.g., baud rate, data, bits, stop bits, parity, and flow control) and the message format to the "host" computer. Set or modify the communications parameters for Serial Port #1 using the Mode drop list (to select RS232 or RS422). Click the appropriate option group buttons to define the baud rate, data bits, stop bits, parity, and flow control.

05-AXIOM-AXIOM-X_Setup_R10.doc

Accu-Sort Systems, Inc.

85

Page 86

86

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

Message Format You have four format selections for messages the AXIOM reader sends to your host computer (or other device) connected to port#1. Selection Custom Message Standard Message

User defined Message

MUX (ADP) Message

Definition Enables custom messaging implemented via custom software Default reader message. Header = <STX> Trailer = <CR><LF> Separator = “,” (comma) No-read = “?” Enables you to define specific message formats. The Modify > Message Definitions – Port#1 window is available when you select this message format. (See also Creating User Defined Messages.) Message format for communicating with an Accu-Sort MUX.

When ACK/NAK Flow Control is selected, the Retry Count drop-down list and Timeout (in ms) options become available.

Modify > Serial Communications Port#1 (ACK/NAK enabled) Retry Count for ACK/NAK flow control can be set for 1 to 10 retries. TimeOut (ms) sets the ACK/NAK flow control timeout anywhere from 100ms to 30,000ms. Enter a number outside this range and an error message is displayed when you attempt to move on to the next step.

Accu-Sort Systems, Inc.

05-AXIOM-AXIOM-X_Setup_R10.doc

Page 87

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

Network Settings The Modify > Network Settings window allows you to specify network settings (including the IP address) for the reader. Currently, the reader can only be configured to use a Static IP address. Net Host Port1 and Net Host Port2 define two network connections for sending bar code messages. The Connection Type and Message Format for each port can be set independently. Message formatting is the same as for the serial port.

05-AXIOM-AXIOM-X_Setup_R10.doc

Accu-Sort Systems, Inc.

87

Page 88

88

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

Network Settings Field IP Address Net Mask

Gateway IP Address Net Host Port1 or Net Host Port2

Controller/Client Configuration

Ethernet Link

Definition An IP address specifies a unique host ID for the reader on a particular TCP/IP network. Consult your network administrator for a valid IP address for the reader. A net mask modifies a standard IP address into subnets. A default class C net mask should be valid in most cases (either 255.255.255.0 or 255.255.240.0). Consult your network administrator for the net mask value. A gateway allows the reader to reach other systems not on the local network and remote systems to reach the reader. If the reader requires external connectivity, consult your network administrator for a valid gateway address. Connection Type – The following connections types are available for each network port: ƒ TCP/IP Server: As a TCP/IP server, a Port # must be specified. In this case it is the TCP/IP client’s responsibility to initiate an AXIOM connection. ƒ TCP/IP Client: As a TCP/IP client, aside from the Port #, the Remote IP Address of the TCP/IP server which is to receive the bar code messages must be specified. The Reconnect Time specifies the interval (in seconds) at which the AXIOM attempts to establish a connection. ƒ UDP Messaging: In some instances, it may be desirable to use a connectionless UDP message to send bar code data. In this case, only the Port # and Remote IP Address of the receiver need to be specified. ƒ EtherNet/IP (Net Host Port1 only): This enables use of the EtherNet/IP protocol on the AXIOM. Message Format: There are four message format options: Custom Message, Standard Message, User Defined Message and MUX (ADP) Message. Number of Client Readers - This number in a multi-reader network must be defined on the AXIOM Controller. Drop-down list selectable for up to five (5) AXIOM readers functioning as “Clients”. Client readers must be set at zero (0). Group Number – All AXIOM readers in a Controller/Client group (both the Controller and ALL Clients) must be set to the same controller group number. The default of zero (0) disables a reader from listening for messages to become a client. Drop-down List with 2 selections: 10 Mbps/Full Duplex, 10 Mbps/Half Duplex

Message Format Selection Custom Message Standard Message User defined Message MUX (ADP) Message

Accu-Sort Systems, Inc.

Definition Enables custom messaging implemented via custom software Default reader message (header <STX> trailer <CR> <LF> ). Enables you to define specific message formats. The Modify > Message Definitions – Net#1 window is available when you select this message format. (See also Creating User Defined Messages.) Message format for communicating with an Accu-Sort MUX.

05-AXIOM-AXIOM-X_Setup_R10.doc

Page 89

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

Advanced Network Settings The advanced network parameters are only available when Advanced Setup is selected from Configuration drop-down menu. Under normal circumstances, these should never need to change.

Selection Controller Multicast IP address Setup Port # Telnet Port #

05-AXIOM-AXIOM-X_Setup_R10.doc

Definition During Controller/Client operations, the controller uses TCP/IP multicasting to communicate with the clients. The group number represents the low byte of the Multicast IP Address that is used. TCP/IP port number used for setup. Changing this can cause problems with AXCESS, which always uses port 2001. TCP/IP port for terminal interface.

Accu-Sort Systems, Inc.

89