Page 72

72

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

To open a communication port: 1. Click the Open Port button. 2. Once the reader connection is complete, the message “Connected by serial cable” appears in the status line. 3. The Connection window displays the Reader’s Information. The type of AXIOM (1L, 2L, 4L) or AXIOM-X (2L, 4L) is identified in the Reader model line.

Connection – Open Port 4. If a connection is not made, “No reply received from AXIOM” message is displayed. 5. Check the cable connection between the reader and computer to assure proper connection, and then click Open Port.

Reader’s Information Buttons Button Save Retrieve Default

Definition Saves the reader information to scan head. Retrieves the reader information from scan head. Returns the reader configuration to the default settings.

NOTE: Selecting Default will return your reader to the default factory settings. Since your AXIOM may have been pre-configured for your application at the factory, it is recommended that you ALWAYS save your reader parameters to disk before using the default function.

Accu-Sort Systems, Inc.

05-AXIOM-AXIOM-X_Setup_R10.doc

Page 73

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

To connect to an AXIOM via network: 1. Confirm the AXIOM is properly connected to your Ethernet network. (See Chapter 3.) 2. Assign a valid IP address to the AXIOM. 3. In the Connection Mode options group, click Network. 4. Select the IP address of your AXIOM from the Reader’s IP Address list. (If this is your first time, you may need to add the AXIOM’s IP address to the Reader’s IP Address list.) 5. To verify the AXIOM can be accessed on the network, click Ping. The status will be returned in the Reader’s Status column on the Connection window. 6. To connect to the AXIOM over the network, click Connect. NOTE: If you have enabled the use of a password for all network access, you will be prompted for a password after this step.

AXCESS Connection Window with Network Selected Button Add IP Remove Connect Ping

05-AXIOM-AXIOM-X_Setup_R10.doc

Definition Opens the Add/Edit IP Address popup window. Enables removal of the selected Reader’s IP Address. Allows you to connect to the selected reader. Checks network communications with the selected reader.

Accu-Sort Systems, Inc.

73

Page 74

74

Setup

AXIOM™ / AXIOM-X™ Product Line Manual

To add an AXIOM to the Reader’s IP Address list 1. Click the Add IP button. The Add/Edit IP Address popup window appears.

2. Enter the IP address and reader name in the fields. 3. Click Add. The IP address and reader name will appear in the TCP/IP connection fields of the Connection Mode screen. 4. Repeat steps 2 and 3 in the Add/Edit IP Address popup window to enter as many AXIOM readers as necessary for your application. 5. Click Exit to return to the Connection Mode screen.

Accu-Sort Systems, Inc.

05-AXIOM-AXIOM-X_Setup_R10.doc

Page 75

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

Modify After establishing a connection with your AXIOM reader, use the Modify menu to set all operational parameters to fit your application. NOTE: AXCESS functionality varies based on the type of AXIOM reader you are setting up. Functions that do not apply to your reader will either not appear on the active screen or will appear grey (rather than black) indicating the function is not applicable. The parameters are divided into the following categories: ƒ

AXIOM Configuration

ƒ

Bar Code Setup

ƒ

Bar Code Padding and Stripping

ƒ

Match Codes Setup

ƒ

Serial Communications Port #1

ƒ

Network Settings

ƒ

Trigger and Relay Settings

ƒ

Tracking

The following Modify menu items only appear if another function is enabled: ƒ

Bar Code Groups

(Multiple Codes enabled)

ƒ

FAST Monitor Configuration

(Collect FAST Monitor Statistics selected)

ƒ

User Defined Mod Checks

(Advanced Setup selected)

ƒ

Message Definition – Port #1

(User Defined Message selected)

ƒ

Message Definition – Net #1

(User Defined Message selected)

ƒ

Message Definition – Net #2

(User Defined Message selected)

ƒ

EtherNet/IP

ƒ

DRX

(EtherNet IP selected as Message Format of Net Host Port1) (Advanced Setup selected)

NOTE: Select Advanced Setup from the Configuration drop-down menu (Configuration > Setup > Advanced).

05-AXIOM-AXIOM-X_Setup_R10.doc

Accu-Sort Systems, Inc.

75

Page 76

76

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

AXIOM Configuration Use the Modify > AXIOM Configuration window to define the reader name and identify the related software names, revisions, and configuration options.

Reader Information The Reader Information region of the AXIOM Configuration screen identifies the reader name and current software revisions being used by the AXIOM scan head. Modify > AXIOM Configuration > Reader Information Field Reader Name

Reader Model

AXIOM Software Name / Revision Decode Software Name / Revision

Accu-Sort Systems, Inc.

Definition User-defined reader name (up to 15 characters). Useful when it is necessary to identify multiple AXIOM readers within the same building or application. Identifies the type of reader to which AXCESS is connected (e.g., AXIOM 1L, 2L, 4L or AXIOM-X-2L, AXIOM-X-4L). Name of AXIOM software and revision number. Cannot be modified. Name of decoder software and revision number. Cannot be modified.

05-AXIOM-AXIOM-X_Setup_R10.doc

Page 77

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

Configuration Options Use the Configuration Options to setup the laser configuration and scan rate if it becomes necessary to change the factory settings to optimize reader performance for your application. Modify > AXIOM Configuration > Configuration Options Field Laser Configuration

Definition

Scan Rate

Allows you to change the scan rate. Changing scan rate and then saving parameters causes the AXIOM to reboot. AXIOM 700 – 1400 scans/second AXIOM-X 700 – 1120 scans/second Enabling this function results in the following: Non-Tracking: Lasers turn off whenever “trigger” is not active. Tracking: Lasers turn off whenever the belt speed is zero or a package has not been detected for two minutes. Enabling this function results in the following: FAST Monitor Configuration selection becomes available in the menu tree under Modify. (See Appendix D.)

Enable Trigger or Tach Controlled Laser (checkbox) Collect FAST Monitor Statistics (checkbox)

Allows you to specify whether or not laser toggling is enabled. When not enabled, you can select whether the “near” or “far” lasers are used. The Laser Configuration option buttons are enabled only if in Advanced setup mode.

CAUTION: Changing the scan rate and/or laser configuration can adversely affect reader performance. Do not change the scan rate or laser configuration unless instructed to do so by Accu-Sort Technical Support.

Control Panel Options The AXIOM’s control panel is very useful during setup. When the Enable AXIOM Control Panel Buttons checkbox is selected, you will be able to use the AXIOM reader’s control panel. (See Chapter 6.) Once setup is complete, disable the control panel buttons to reduce the potential for accidentally changing parameters at the scanning area. Clear the checkbox to assure the buttons cannot be erroneously activated. Modify > AXIOM Configuration > Control Panel Options Selection Use ! Button For Test Mode Use ! Button to Learn Match Code

05-AXIOM-AXIOM-X_Setup_R10.doc

Definition Activate the test mode by pressing the “!” button. Unit operates in Test Mode, but the last code read is also stored in the match code table.

Accu-Sort Systems, Inc.

77

Page 78

78

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

Network Access Options Control AXIOM network access through these options: ƒ

Password for FTP Only

ƒ

Password for All Net Access

Modify > AXIOM Configuration > Network Access Options Selection Password for FTP Only

Password for All Net Access

Definition When selected, FTP access to an AXIOM reader is enabled when the correct password is entered. Use FTP to update and extract the AXIOM firmware and parameter settings. The username for FTP access is always “axiom”. In addition to FTP connections, a password is also required for network connections from AXCESS and Telnet connections. Host communications are not affected.

NOTE: If a password is not entered in the field, or an incorrect password is entered, the selected network access option is disabled.

Accu-Sort Systems, Inc.

05-AXIOM-AXIOM-X_Setup_R10.doc

Page 79

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

Bar Code Setup Use Modify > Bar Code Setup to define what symbologies the AXIOM should be reading for your application. Additionally, mod-check verification within a bar code can be specified. AXCESS provides up to four windows for setting bar code parameters: ƒ ƒ ƒ ƒ

Bar Code Setup Bar Code Groups Bar Code Padding and Stripping Match Code Setup

The Active Bar Code List identifies all bar code types (maximum 10) and their associated parameters (e.g.: Code #, Code Type, Characters, Mod Check, Quantity) that the AXIOM reader has been setup to search for and decode. The code quantity is specified by a minimum and maximum number of codes. These parameters control what is reported as a “no-read” or a “multiple code.” For example, if a Code128 is specified with a minimum quantity of 1 and a maximum quantity of 2, the reader can read one or two Code128 codes during a trigger cycle without reporting a problem. However, if no codes were read, one no-read message would be sent. If three codes were read, a “multiple codes” condition would be reported. NOTE: The minimum quantity can be set to zero. This allows you to disable reporting of no-reads for a particular code type.

Button Move Up Move Down Edit Add Remove

05-AXIOM-AXIOM-X_Setup_R10.doc

Definition Move a symbology toward the top (beginning) of the list Move a symbology further back (toward the end) of the list Enable changes to a symbology already on the active list Enables the addition of a new symbology to the active list Enables the removal of a symbology to the active list

Accu-Sort Systems, Inc.

79

Page 80

80

AXIOM™ / AXIOM-X™ Product Line Manual

Setup

Moving a Bar Code Highlight a symbology (Code#) listed in the bar code fields. To move the selected symbology toward the top (beginning) of the list, click Move Up. Click Move Down to move the selected symbology further back (toward the end) of the list. Editing a Bar Code Highlight the symbology (Code#) listed in the bar code fields that you want to edit. Click Edit. The highlighted symbology appears in a modal window. The available parameters are shown in the Code Settings window.

To change any of the settings (e.g. Symbology, Code Length, Mod Check, or Quantity) use the drop-down lists to select the required changes. Click Ok to save the code settings. Cancel to return to the Bar Code Setup window without saving any changes or additions. NOTE: The Data Filter allows a “match pattern” to be specified for a bar code definition. This restricts this code definition to only bar codes that match this pattern. Example: Setting “9*” as a data filter defines that only bar codes that start with a nine will be accepted. Only one '*' may be entered in the Data Filter field. Adding a Bar Code Click Add. A modal window is displayed. Review the drop-down list settings (e.g., Symbology, Code Length, Mod Check, or Quantity). Be sure to select the required parameters for the symbology you are adding to your active list. Select the symbology you want to add using the drop-down list. Be sure to select the correct minimum and maximum code length. Select the necessary Mod Check from the drop-down list. (See also User-Defined Mod Checks.) Removing a Bar Code Highlight the Code# in the Bar code Setup window that you want to remove. Click Remove. The code will disappear from the list.

Accu-Sort Systems, Inc.

05-AXIOM-AXIOM-X_Setup_R10.doc