Page 57
THEORY OF OPERATION BASIC FUNCTIONAL DESCRIPTION The Models 1708 and 1716 Remote Terminal Units are microprocessor-based systems with a software intensive architecture that greatly enhances the versatility of the RTUs and allows them to be quickly adapted to varied tasks. The microprocessor controls all internal operations, radio audio path control, RS-232 serial port and external input/output interface operations. FUNCTIONAL BLOCK DIAGRAM
External Audio
AUX Inputs Transmit Request COR
RS-232 In RS-232 Out
MSK Modem
Input Protector/ Buffers
RS-232
(For local programming only)
Microprocessor
Discriminator
Audio Processing & Gain
Summing Audio Amplifier
Audio Out
Output Latch/ Buffer
PTT Auxiliary Control Outputs
Digital Outputs/Inputs
Outside World
Analog Inputs/Outputs
Outside World
Figure 7. RTU Functional Block Diagram
025-9209
47
Page 58
(ZETRON),
Theory of Operation
48 025-9209
Page 59
TROUBLESHOOTING GUIDE OVERVIEW In case of installation or operational difficulty, call Zetron at (425) 820-6363. Please have the serial number of the unit and/or the Zetron order number. If the call is made from the installation site by the installer or radio technician, the problem can usually be solved over the telephone. Some commonly encountered problems can be solved by following the recommendations below. Problem:
Unit will not communicate with PC or dumb terminal.
Recommendations:
Make sure you are using some communications software such as Cross-Talk, Pro-Comm, Kermit, or ZCU or you are using a dumb terminal. You cannot access the programming mode directly from DOS. Verify the baud rate at 4800, 8 bit, no parity, 1 stop bit with echo off. Verify that you have specified the correct communications port. You should see between -6 and -12 Vdc on pins 3 and 4 (Ref. to ground) of J1, the black 9-pin connector, when the RTU is connected to the PC and both the PC and RTU have power. If you do not see these voltages, check the connections; most often they are reversed. There should be a common ground reference for the RTU and the PC or terminal. Press the space bar three times to access the menu.
Problem:
Unit will not key the radio.
Recommendations:
Check jumpers JP6 and JP7. Make sure Channel Busy Detect is set correctly.
025-9209
49
Page 60
Troubleshooting Guide Problem:
Units will not communicate.
Recommendations:
Check address on RTU and Controller. Verify setting of DIP switch 7 and 8 on Controller.