Page 11

Getting Ready to Print Battery Installing the Battery Important • Batteries are shipped partially charged. Remove protective shrink-wrap and labels from new battery packs prior to use.

1. Rotate the belt clip to allow access to the battery compartment. 2. Insert the battery into the printer as shown in Figure 2. 3. Rock the battery into the printer as shown until it locks in place. When the battery is first installed, the control panel indicators may briefly turn on and then go off which indicates the battery is not fully charged (see “Charging the Battery” below and “Operator Controls”). You must charge the batteries fully before using them for the first time. To ensure maximum battery capacity, new batteries should go through two or three complete charge/discharge cycles when first put into service. Figure 2: Installing the Battery Belt Clip

Battery Belt Clip

Charger Jack Battery

QL 220 Plus

QL 320 Plus Belt Clip

Charger Jack QL 420 Plus 11 QL Plus Series User Guide

Page 12

Charging the Battery with the LI72 Charger Figure 3: LI72 Single Charger LI72 Charger

Battery Pack

Charger Jack

Figure 4: LI72 Single Charger Types

Yellow

Charging Trickle Charging Fault Condition

LI72 2-Wire Charger

LI72 3-Wire Charger

12 QL Plus Series User Guide

Green

Page 13

The LI72 is a wall mounted fast charger with universal 110 to 230, 50-60 Hz. VAC input. Multiple A.C. plug configurations comply with most international standards. This charger is intended for use with Lithium Ion (Li-ion) batteries. QL series printers only utilize Li-ion batteries. The LI72 is supplied in two variations: a two wire version and a three-wire version. The three-wire version offers more intelligent charging features and is used with more-recently produced printers.. Both of the LI72 models will charge a battery pack as fast as its charge level will allow, and then switch over to a maintenance charge to keep the charge at its maximum. Charging Battery Packs with the LI72 Two-Wire Version

Plug the LI72 into the appropriate A.C. wall receptacle, and then insert the charge cable into the battery pack charger jack. The charge indicator LED will indicate the status of the charger as follows: Indicator Steady Slow Flashing (1 HZ)

Rapid Flashing (4 Hz)

Charger Function

Charger Status

Charging.

Battery Pack is undergoing a fast charge

Maintain

Battery is ready for use

Error

The battery may have an internal short, or its charge monitoring circuitry may be malfunctioning. The battery pack should not be used any further.

Do not charge batteries with the two-wire LI72 model while printing. Attempting to print while charging can result in improperly charged batteries. Caution • Do not leave the two-wire charger plugged into a battery pack for a prolonged period of time when it is installed in the printer and has reached the maintenance charge state. Charging a battery when installed in a printer for a prolonged period of time could cause damage to the printer.

13 QL Plus Series User Guide

Page 14

Charging Battery Packs with the LI72 Three-Wire Version

Plug the LI72 into the appropriate A.C. wall receptacle, and then insert the charge cable into the battery pack charger jack. The yellow/green charge indicator LED will indicate the status of the charger as per the following table. Do not charge batteries with the three-wire LI72 model while printing. Attempting to print while charging can result in improperly charged batteries. Charger Function

Indicator Steady yellow indicator

Standby

Charger Status AC power on; no battery being charged

Slow (1 Hz) flashing yellow indicator

Pre-Charge

Charger is applying trickle charge current (5% of maximum) to bring a cold battery temperature up to 0°C before starting a full charge cycle

Fast (4 Hz) flashing green indicator

Rapid Charge

Charger is applying the maximum charge rate to the battery

Slow (1 Hz) flashing green indicator

Maintain

Charger is in trickle charge mode(10% of nominal charge value).

Fast (4 Hz) flashing yellow indicator

Error

The battery may have an internal short, or its charge monitoring circuitry may be malfunctioning. The battery pack should not be used any further.

Steady green indicator

Ready

No charge is being applied to the battery

Wait

Battery temperature is too hot. Charging will not begin until battery temperature reaches 45°C.

Slow (1 Hz) flashing alternate yellow and green indicator

Charging will cease three (3) hours after the charger has entered the “Maintain” mode.

14 QL Plus Series User Guide

Page 15

Model UCLI72-4 Quad Charger Figure 5: Quad Charger

Power Supply 1. Slide Battery Pack into Charger bay

2. Rock Battery Pack into place

Fast Faul t

Char ge

Full

Char ge

Read y Fast Faul t

Char ge

Full

Char ge

Read y Fast Faul t

Char ge

Full

Char ge

Read

Amber Indicator y Fast Faul

Char ge t

Powe

Charger Bay Green Indicator

Full

Char ge

Read y r

Power Indicator

The UCLI72-4 Quad Charger is designed to charge up to four QL series battery packs simultaneously. Batteries must be removed from the printer to be charged in the Quad Charger. 1. Ensure that the charger has been installed properly per the Quad Charger instruction manual. Ensure that the power indicator on the front panel is on. 2. Remove any protective shrink-wrap and labels from all battery packs prior to use. Plug a battery pack into any one of the four charging bays as shown in Figure 5, noting the orientation of the battery pack. Slide the battery pack into the charging bay until it stops and then rock the battery pack back until it snaps into place. The amber indicator dicontinued 15 QL Plus Series User Guide

Page 16

rectly under the battery being charged will turn on if the battery is properly inserted. The indicators under the battery will allow you to monitor the charging process per the table below: Amber

Green

On

Battery Status

Off

Charging

On

Flashing

80% charged (O.K. to use)

Off

On

Completely Charged

Flashing

Off

Fault

Important • A fault condition is caused by a problem with the battery. The charger may indicate a fault because the battery is too hot or cold to charge reliably. Try to charge the battery again when it returns to the room’s ambient temperature. If the amber indicator starts flashing on the second attempt, the battery should be discarded. Always dispose of batteries in a proper manner as described in Appendix E.

Quad Charger Cycle Times : Battery Status

QL 220Plus & QL 320 Plus

QL 420 Plus

Battery 80% Charged

1.25 Hrs.

2.5 Hrs.

Battery Fully Charged

2.5 Hrs.

5 Hrs.

Note • These times are for completely discharged batteries.

Battery packs which are only partially discharged will take less time to reach their charged state. Batteries which have reached 80% of their charge capacity may be used, however, it is recommended that you allow the batteries to reach a full charge to maintain maximum battery life. The UCLI72-4 Quad Charger has a safety feature which stops charging a battery after six hours regardless of its charge state.

16 QL Plus Series User Guide

Page 17

Battery Safety Caution • Avoid accidental short circuiting of any battery. Allowing battery terminals to contact conductive material will create a short circuit which could cause burns and other injuries or could start a fire. Important • Always refer to the Important Safety Information data sheet shipped with each printer and the Technical Bulletin shipped with each battery pack. These documents detail procedures to ensure maximum reliability and safety while using this printer. Important • Always dispose of used batteries properly. Refer to Appendix E for more battery recycling information. Caution • Use of any charger not approved specifically by Zebra for use with its batteries could cause damage to the battery pack or the printer and will void the warranty.

Charger Safety Do not place any charger in locations where liquids or metallic objects may be dropped into the charging bays. Use care when installing either the LI72 Single Chargers or the UCLI72-4 Quad Charger so that you do not block the ventilating slots on the top and bottom covers. Ensure that the charger is plugged into a power source which will not accidently be turned off if you will be charging batteries overnight.

17 QL Plus Series User Guide

Page 18

Loading the Media You can operate QL Plus printers in one of two different modes: Tear-Off or Peel-Off. Tear-Off mode allows you to tear off each label (or a strip of labels) after it is printed. In Peel-Off mode, the backing material is peeled away from the label as it is printed. After you remove this label, the next one is printed. QL 420 Plus and QL 220 Plus Printers 1. Open the printer: Refer to Figure 6 (QL 420 shown). • Press the latch release button on the side of the printer as shown at “1” below. The latch assembly will flip open automatically • On the QL 420 Plus only, pull up the latch assembly completely as shown at “2” to unlatch the Media Cover. • Rotate the Media Cover back as shown at “3”, exposing the media compartment and the adjustable media supports. Figure 6: Opening the QL 420 Plus & QL 220 Plus

Media Compartment

Media Supports

18 QL Plus Series User Guide

Page 19

QL 320 Plus Printers 1A. Open the printer: Refer to Figure 6a. • Rotate the latch release levers on each side of the printer as shown at “1” below. The latch assembly will flip open automatically as shown at “2”. • Rotate the Media Cover back as shown at “3”, exposing the media compartment and the adjustable media supports. Figure 6a: Opening the QL 320 Plus

Media Compartment

Media Supports

19 QL Plus Series User Guide continued