Page 58

Troubleshooting Figure 25 QL Plus Control Panels Green LED

Yellow LED

Keypad Control Panel Status icons

LCD Control Panel

Keypad Control Panel If the printer is not functioning properly, refer to the chart below to find the state of the two LEDs on the Keypad Control Panel. Then refer to the Troubleshooting topic referenced in the chart to resolve the problem. Green LED

Yellow LED

Indication

Steady

Off

Normal Operation, and/or RF Link established

Ref. to Topic n/a

Off

Off

Power Off

1

Fast Blink

Off

No RF Link

6, 11

Slow Blink

Off

Low Battery

3, 6, 7

Steady

Steady

Out of media, or Media Cover not closed

9, 11

Steady

Fast Blink

Normal RF activity

8

Steady

Fast Blink , Beeper Sounds

No application

8

58 QL Plus Series User Guide

Page 59

LCD Control Panel Indicators The top of the display shows several icons which indicate the status of various printer functions. Check the indicator status, then refer to the Troubleshooting topic referenced in the chart to resolve the problem. Icon

Status

Indication

On

Bluetooth Link established

Ref. to Topic # n/a

Off

No Bluetooth Link

6

On

Bluetooth link established n/a

Off

No Bluetooth link

6

Flashing

Transmitting/Receiving data n/a

On

802.11b/g RF Link established n/a

Off

No 802.11b/g RF Link

6

Flashing

Low Battery

3, 6, 7

Flashing

Head latch not closed

9, 11

Flashing

Indicates Printing activity n/a

Steady data processing in process

8

Flashing

Out of Media

9,11

Blank Screen n/a

No application

QL Plus printers may have one of two LCD types. LCDs using the Bluetooth icon (highlighted by a gray background in the table above) will gradually replace LCDs with the “light bulb” icon indicating Bluetooth activity. Printers with either type of display will function identically. The “right facing” arrow icon will be activated in both LCD versions on printers with the latest firmware updates.

continued 59 QL Plus Series User Guide

Page 60

Troubleshooting Topics 1. No power • Check that battery is installed properly. • Recharge or replace battery as necessary. Always dispose of batteries properly. Refer to Appendix E for more information on proper battery disposal.

2. Media does not feed: • Be sure print head is closed and latched. • Check spindle holding media for any binding. • If unit is equipped with label presence sensor: Ensure most recently printed label is removed. Also ensure label sensor is not blocked.

3. Poor or faded print or flashing:

• Clean print head. • Check battery and recharge or replace as necessary. Always dispose of batteries properly. Refer to Appendix D for more information on proper battery disposal. • Check quality of media.

4. Partial or missing print: • Check media alignment • Clean print head. • Ensure printhead is properly closed and latched.

5. Garbled print: • Check baud rate.

6. No print: • Check baud rate. • Replace battery. • Check cable to terminal. • Establish RF Link (Wireless units only) and/or restore LAN associativity (Printers with WLAN radios only). • Invalid label format or command structure. Place printer in Communications Diagnostic (Hex Dump) Mode to diagnose problem.

7. Reduced battery charge life • Check battery date code, if battery is one to two years old, short charge life may be due to normal aging. • Recondition battery. • Replace battery.

60 QL Plus Series User Guide

Page 61

8. Yellow error light or flashing:

• No application or application corrupted: reload program. • If using wireless communications: flashing indicator is normal while data is being transmitted or received.

9. Yellow error light always on, or flashing:

• Check that media is loaded and that the print head is closed and securely latched.

10. Skips labels: • Check media for top of form sense mark or label gap. • Check that the maximum print field has not been exceeded on label. • Ensure bar or gap sensor is not blocked or malfunctioning

11. Communication error: • Check media is loaded, head is closed and error light is off. • Check baud rate. • Replace cable to terminal.

12. Label jam: • Open head release latch and media cover. • Generously apply alcohol to printer in area of jammed label.

13. Blank LCD screen (only for units with LCD control panel) • No application loaded or application corrupted: reload program.

61 QL Plus Series User Guide

Page 62

Troubleshooting Tests Printing a Configuration Label To print out a listing of the printer’s current configuration follow these steps: 1. Turn the printer off. Load the media compartment with journal media (media with no black bars printed on the back). 2. Press and hold the Feed Button. 3. Press and release the Power button and keep the Feed button pressed. When printing starts, release the Feed button. Refer to Figure 26 for sample configuration printouts. Communications Diagnostics If there is a problem transferring data between the computer and the printer, try putting the printer in the Communications Diagnostics Mode (also referred to as the “DUMP” mode). The printer will print the ASCII characters and their text representation (or the period ‘.’, if not a printable character) for any data received from the host computer. To enter Communications Diagnostics Mode: 1. Print a configuration label as described above. 2. At the end of 2nd diagnostics report, the printer will print: “Press FEED key to enter DUMP mode”. 3. Press the FEED key. The printer will print: “Entering DUMP mode”. Note • If the FEED key is not pressed within 3 seconds, the printer will print “DUMP mode not entered” and will resume normal operation.

4. At this point, the printer is in DUMP mode and will print the ASCII hex codes of any data sent to it, and their text representation (or “.” if not a printable character). Additionally, a file with a “.dmp” extension containing the ASCII information will be created and stored in the printer’s memory. It can be viewed, “cloned” or deleted using the Label Vista application. (Refer the Label Vista documentation for more information.) 62 QL Plus Series User Guide

Page 63

To terminate the Communications Diagnostics Mode and return the printer to normal operations: 1. Turn the printer OFF. 2. Wait 5 seconds. 3. Turn the printer ON. Contacting Technical Support If the printer fails to print the configuration label, or you encounter problems not covered in the Troubleshooting Guide, contact Zebra Technical Support. Technical Support addresses and phone numbers for your area can be found in Appendix D of this manual. You will need to supply the following information: • Model number and type (e.g. QL 420 Plus) • Unit serial number (Found on the large label on the back of the printer, also found in the configuration label printout. Refer to Figure 26) • Product Configuration Code (PCC) (15 digit number found on the label on the back of the unit)

63 QL Plus Series User Guide

Page 64

Print Head Test Identifies Printer as a QL Plus series

End of First Report

Unit Serial Number Application Number

Report appears only on units with wireless options installed. Units with no wireless options will print an empty line and resume This unit has a 802.11b radio option installed. This section details the radio’s network settings

Figure 26: QL Plus Configuration Label Example 64 QL Plus Series User Guide

Page 65

Peripherals installed: In this example the LCD display option is installed. Memory Installed

Maximum Label Size

Resident Human Readable fonts installed

Figure 26a: QL Plus Configuration Label Example (continued) 65 QL Plus Series User Guide continued

Page 66

Files Loaded in Printer Memory (will include Pre-scaled or Scalable Fonts)

EPL and ZPL emulation is standard on QL Plus series

Figure 26b: QL Plus Configuration Label Example (continued) 66 QL Plus Series User Guide