Page 137

CHAPTER 9 RS-232 INTERFACE Introduction This chapter describes how to set up the scanner with an RS-232 host. The scanner uses the RS-232 interface to connect to point-of-sale devices, host computers, or other devices with an available RS-232 port (e.g., com port). The scanner ships with the settings shown in Table 9-1 on page 9-3 (also see Appendix A, Standard Default Parameters for all defaults). If the default values suit requirements, programming is not necessary. If your host does not appear in Table 9-2, refer to the documentation for the host device to set communication parameters to match the host. NOTE The scanner uses TTL RS-232 signal levels, which interface with most system architectures. For system architectures requiring RS-232C signal levels, Zebra offers different cables providing TTL-to-RS-232C conversion. Contact the Zebra Support & Downloads website for more information.

Setting Parameters To set feature values, scan a single bar code or a short bar code sequence. The settings are stored in non-volatile memory and are preserved even when the scanner powers down. NOTE Most computer monitors allow scanning bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where you can see the bar code clearly, and bars and/or spaces do not merge.

To return all features to default values, scan Set Factory Defaults on page 5-5. Throughout the programming bar code menus, asterisks (*) indicate default values.

* Indicates default

*Enable Parameter

Feature/option

Page 138

9 - 2 DS2208 Digital Scanner Product Reference Guide

Scanning Sequence Examples In most cases scanning one bar code sets the parameter value. For example, to set the baud rate to 19,200, scan the Baud Rate 19,200 bar code under Baud Rate on page 9-8. The scanner issues a fast warble beep and the LED turns green, signifying a successful parameter entry. Other parameters require scanning several bar codes. See the parameter descriptions for this procedure.

Errors While Scanning Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.

Connecting an RS-232 Interface Connect the scanner directly to the host computer.

Serial port connector to host

Interface cable

Power supply

Figure 9-1

RS-232 Connection

NOTE Interface cables vary depending on configuration. The connectors can be different than those illustrated in Figure 9-1, but the steps to connect the scanner are the same.

1.

Attach the modular connector of the RS-232 interface cable to the cable interface port on the scanner. See Installing the Interface Cable on page 1-3.

2.

Connect the other end of the RS-232 interface cable to the serial port on the host.

3.

If required, connect the power supply to the serial connector end of the RS-232 interface cable. Plug the power supply into an appropriate outlet.

Page 139

RS-232 Interface 9 - 3

4.

The scanner automatically detects the host interface type and uses the default setting. If the default (*) does not meet your requirements, select another RS-232 host type by scanning the appropriate bar code from RS-232 Host Types on page 9-6.

5.

To modify any other parameter options, scan the appropriate bar codes in this chapter.

If problems occur with the system, see Troubleshooting on page 4-3.

RS-232 Parameter Defaults Table 9-1 lists defaults for RS-232 host parameters. Change these values in one of two ways:

• Scan the appropriate bar codes in this chapter. The new value replaces the standard default value in memory. To recall default parameter values, see Default Parameters on page 5-5.

• Configure the scanner using the 123Scan2 configuration program. See Chapter 2, 123Scan and Software Tools. NOTE See Appendix A, Standard Default Parameters for all user preference, host, symbology, and miscellaneous default parameters.

Table 9-1

RS-232 Interface Parameter Defaults Parameter

Default

Page Number

RS-232 Host Parameters RS-232 Host Types

Standard

9-6

Baud Rate

9600

9-8

Parity

None

9-9

Stop Bits

1 Stop Bit

9-9

Data Bits

8-bit

9-10

Check Receive Errors

Enable

9-10

Hardware Handshaking

None

9-11

Software Handshaking

None

9-13

Host Serial Response Timeout

2 Sec

9-15

RTS Line State

Low RTS

9-16

Beep on <BEL>

Disable

9-16

Intercharacter Delay

0 msec

9-17

Nixdorf Beep/LED Options

Normal Operation

9-18

Bar Codes with Unknown Characters

Send Bar Code With Unknown Characters

9-18

Page 140

9 - 4 DS2208 Digital Scanner Product Reference Guide

RS-232 Host Parameters Various RS-232 hosts use their own parameter default settings. Selecting standard, ICL, Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olivetti, Omron, or Common Use Terminal Equipment (CUTE-LP/LG bar code readers) sets the defaults listed in Table 9-2. Table 9-2

Terminal Specific RS-232

Parameter

ICL

Fujitsu

WincorNixdorf Mode A

WincorNixdorf Mode B/OPOS/JPOS

Olivetti

Omron

CUTE

Transmit Code ID

Yes

Yes

Yes

Yes

Yes

Yes

Yes

Data Transmission Format

Data/Suffix

Data/Suffix

Data/Suffix

Data/Suffix

Prefix/Data/ Suffix

Data/Suffix

Prefix/Data/ Suffix

Suffix

CR (1013)

CR (1013)

CR (1013)

CR (1013)

ETX (1002)

CR (1013)

CR (1013) ETX (1003)

Baud Rate

9600

9600

9600

9600

9600

9600

9600

Parity

Even

None

Odd

Odd

Even

None

Even

Hardware Handshaking

RTS/CTS Option 3

None

RTS/CTS Option 3

RTS/CTS Option 3

None

None

None

Software Handshaking

None

None

None

None

ACK/NAK

None

None

Serial Response Timeout

9.9 Sec.

2 Sec.

None

None

9.9 Sec.

9.9 Sec.

9.9 Sec.

Stop Bit Select

One

One

One

One

One

One

One

ASCII Format

8-Bit

8-Bit

8-Bit

8-Bit

7-Bit

8-Bit

7-Bit

Beep On <BEL>

Disable

Disable

Disable

Disable

Disable

Disable

Disable

RTS Line State

High

Low

Low

Low = No data to send

Low

High

High

Prefix

None

None

None

None

STX (1003)

None

STX (1002)

In the Wincor-Nixdorf Mode A/B, if CTS is low, scanning is disabled. When CTS is high, scanning is enabled. If you scan Wincor-Nixdorf RS-232 Mode A/B without connecting the scanner to the proper host, it may appear unable to scan. If this happens, scan a different RS-232 host type within 5 seconds of cycling power to the scanner. The CUTE host disables all parameter scanning, including Set Defaults. If you inadvertently select CUTE, scan *Enable Parameter Bar Code Scanning (1) on page 5-6, then change the host selection.

Page 141

RS-232 Interface 9 - 5

RS-232 Host Parameters (continued) Selecting ICL, Fujitsu, Wincor-Nixdorf Mode A, Wincor-Nixdorf Mode B, OPOS/JPOS, Olivetti, Omron, or CUTE-LP/LG bar code readers transmits the code ID characters listed in Table 9-3. These code ID characters are not programmable and are separate from the Transmit Code ID feature. Do not enable the Transmit Code ID feature for these terminals. Table 9-3

Terminal Specific Code ID Characters

Code Type

ICL

WincorNixdorf Mode A

Fujitsu

Wincor-Nixdorf Mode B/ OPOS/JPOS

Olivetti

Omron

CUTE

UPC-A

A

A

A

A

A

A

A

UPC-E

E

E

C

C

C

E

None

EAN-8/JAN-8

FF

FF

B

B

B

FF

None

EAN-13/JAN-13

F

F

A

A

A

F

A

Code 39

C <len>

None

M

M

M <len>

C <len>

3

Code 39 Full ASCII

None

None

M

M

None

None

3

Codabar

N <len>

None

N

N

N <len>

N <len>

None

Code 128

L <len>

None

K

K

K <len>

L <len>

5

I 2 of 5

I <len>

None

I

I

I <len>

I <len>

1

Code 93

None

None

L

L

L <len>

None

None

D 2 of 5

H <len>

None

H

H

H <len>

H <len>

2

GS1-128

L <len>

None

P

P

P <len>

L <len>

5

MSI

None

None

O

O

O <len>

None

None

Bookland EAN

F

F

A

A

A

F

None

Trioptic

None

None

None

None

None

None

None

Code 11

None

None

None

None

None

None

None

IATA

H<len>

None

H

H

H<len>

H<len>

2

Code 32

None

None

None

None

None

None

None

GS1 DataBar Variants

None

None

E

E

None

None

None

PDF417

None

None

Q

Q

None

None

6

Data Matrix

None

None

R

R

None

None

4

GS1 Data Matrix

None

None

W

W

None

None

None

QR Codes

None

None

U

U

None

None

7

GS1 QR

None

None

X

X

None

None

None

Page 142

9 - 6 DS2208 Digital Scanner Product Reference Guide

Table 9-3

Terminal Specific Code ID Characters (Continued)

Code Type

ICL

WincorNixdorf Mode A

Fujitsu

Wincor-Nixdorf Mode B/ OPOS/JPOS

Olivetti

Omron

CUTE

Aztec/Aztec Rune

None

None

V

V

None

None

8

Maxicode

None

None

T

T

None

None

None

MicroPDF

None

None

S

S

None

None

6

RS-232 Host Types To select an RS-232 host interface, scan one of the following bar codes. NOTE For a list of supported scanner functionality by communication protocol, see Appendix J, Communication Protocol Functionality.

*Standard RS-2321

ICL RS-232

Wincor-Nixdorf RS-232 Mode A

Wincor-Nixdorf RS-232 Mode B

1Scanning Standard RS-232 activates the RS-232 driver, but does not change port settings (e.g., parity, data bits, handshaking). Selecting another RS-232 host type bar code changes these settings.

Page 143

RS-232 Interface 9 - 7

RS-232 Host Types (continued)

Olivetti ORS4500

Omron

OPOS/JPOS

Fujitsu RS-232

CUTE2

2The CUTE host disables all parameter scanning, including Set Defaults. If you inadvertently select CUTE, scan

*Enable Parameter Bar Code Scanning (1) on page 5-6, and then change the host selection.

Page 144

9 - 8 DS2208 Digital Scanner Product Reference Guide

Baud Rate Baud rate is the number of bits of data transmitted per second. Scan one of the following bar codes to set the scanner's baud rate to match the baud rate setting of the host device. Otherwise, data may not reach the host device or may reach it in distorted form. NOTE The scanner does not support baud rates below 9600.

*Baud Rate 9600

Baud Rate 19,200

Baud Rate 38,400

Baud Rate 57,600

Baud Rate 115,200

Page 145

RS-232 Interface 9 - 9

Parity A parity check bit is the most significant bit of each ASCII coded character. Scan one of the following bar codes to select the parity type according to host device requirements:

• Odd - This sets the parity bit value to 0 or 1, based on data, to ensure that the coded character contains an odd number of 1 bits.

• Even - This sets the parity bit value to 0 or 1, based on data, to ensure that the coded character contains an even number of 1 bits.

• None - No parity bit is required.

Odd

Even

*None Stop Bits The stop bit(s) at the end of each transmitted character marks the end of transmission of one character and prepares the receiving device for the next character in the serial data stream. Scan one of the following bar codes to set the number of stop bits (one or two) based on the number the receiving host can accommodate.

*1 Stop Bit

2 Stop Bits

Page 146

9 - 10 DS2208 Digital Scanner Product Reference Guide

Data Bits This parameter allows the scanner to interface with devices requiring a 7-bit or 8-bit ASCII protocol.

7-bit

*8-bit Check Receive Errors Scan one of the following bar codes to set whether to check the parity, framing, and overrun of received characters. The parity value of received characters is verified against the value set for Parity on page 9-9.

*Check For Received Errors

Do Not Check For Received Errors