Page 129

SSI Interface 8 - 17

Host RTS Line State Parameter # 154 SSI # 9Ah Scan one of the following bar codes to set the expected idle state of the Serial Host RTS line. The SSI interface is used with host applications which also implement the SSI protocol. However, you can use the scanner in a "scan-and-transmit" mode to communicate with any standard serial communication software on a host PC (see Decode Data Packet Format on page 8-17). If transmission errors occur in this mode, the host PC may be asserting hardware handshaking lines which interfere with the SSI protocol. Scan the High bar code to address this problem.

*Low (0)

High (1)

Decode Data Packet Format Parameter # 238 SSI # EEh Scan one of the following bar codes to select whether to transmit decoded data in raw format (unpacketed), or with the packet format defined by the serial protocol. Selecting the raw format disables ACK/NAK handshaking for decode data.

*Send Raw Decode Data (0)

Send Packeted Decode Data (1)

Page 130

8 - 18 DS2208 Digital Scanner Product Reference Guide

Host Serial Response Timeout Parameter # 155 SSI # 9Bh Scan one of the following bar codes to specify how long the scanner waits for an ACK or NAK before resending. Also, if the scanner wants to send, and the host has already been granted permission to send, the scanner waits for the designated timeout before declaring an error. NOTE Other values are available via SSI command.

*Low - 2 Seconds (20)

Medium - 5 Seconds (50)

High - 7.5 Seconds (75)

Maximum - 9.9 Seconds (99)

Page 131

SSI Interface 8 - 19

Host Character Timeout Parameter # 239 SSI # EFh Scan one of the following bar codes to specify the maximum time the scanner waits between characters transmitted by the host before discarding the received data and declaring an error. NOTE Other values are available via SSI command.

*Low - 200 msec (20)

Medium - 500 msec (50)

High - 750 msec (75)

Maximum - 990 msec (99)

Page 132

8 - 20 DS2208 Digital Scanner Product Reference Guide

Multipacket Option Parameter # 334 SSI # F0h 4Eh Scan one of the following bar codes to control ACK/NAK handshaking for multi-packet transmissions: • Multi-Packet Option 1 - The host sends an ACK/NAK for each data packet during a multi-packet transmission. • Multi-Packet Option 2 - The scanner sends data packets continuously, with no ACK/NAK handshaking to pace the transmission. The host, if overrun, can use hardware handshaking to temporarily delay scanner transmissions. At the end of transmission, the scanner waits for a CMD_ACK or CMD_NAK. • Multi-Packet Option 3 - This is the same as option 2 with the addition of a programmable interpacket delay. See Interpacket Delay on page 8-21 to set this delay.

*Multipacket Option 1 (0)

Multipacket Option 2 (1)

Multipacket Option 3 (2)

Page 133

SSI Interface 8 - 21

Interpacket Delay Parameter # 335 SSI # F0h 4Fh Scan one of the following bar codes to specify the interpacket delay if you selected Multipacket Option 3. NOTE Other values are available via SSI command.

*Minimum - 0 msec (0)

Low - 25 msec (25)

Medium - 50 msec (50)

High - 75 msec (75)

Maximum - 99 msec (99)

Page 134

8 - 22 DS2208 Digital Scanner Product Reference Guide

Event Reporting The host can request the scanner to provide certain information (events) relative to scanner behavior. Scan the following bar codes to enable or disable the events listed in Table 8-4 and on the following pages. Table 8-4

Event Codes

Event Class

Event

Code Reported

Decode Event

Non-parameter decode

0x01

Boot Up Event

System power-up

0x03

Parameter Event

Parameter entry error

0x07

Parameter stored

0x08

Defaults set (and parameter event is enabled by default)

0x0A

Number expected

0x0F

Decode Event Parameter # 256 SSI # F0h 00h Scan one of the following bar codes to enable or disable Decode Event. • Enable Decode Event - The scanner generates a message to the host upon a successful bar code decode. • Disable Decode Event - No notification is sent.

Enable Decode Event (1)

*Disable Decode Event (0)

Page 135

SSI Interface 8 - 23

Boot Up Event Parameter # 258 SSI # F0h 02h Scan one of the following bar codes to enable or disable Boot Up Event: • Enable Boot Up Event - The scanner generates a message to the host whenever power is applied. • Disable Boot Up Event - No notification is sent.

Enable Boot Up Event (1)

*Disable Boot Up Event (0)

Parameter Event Parameter # 259 SSI # F0h 03h Scan one of the following bar codes to enable or disable Parameter Event: • Enable Parameter Event - The scanner generates a message to the host when one of the events specified in Table 8-4 on page 8-22 occurs. • Disable Parameter Event - No notification is sent.

Enable Parameter Event (1)

*Disable Parameter Event (0)

Page 136

8 - 24 DS2208 Digital Scanner Product Reference Guide