For the Zebra DS2208

Page 95

CHAPTER 7 USB INTERFACE Introduction This chapter describes how to set up the scanner with a USB host. The scanner connects directly to a USB host, or a powered USB hub, which powers it. No additional power supply is required. The scanner ships with the settings shown in Table 7-1 on page 7-3 (also see Appendix A, Standard Default Parameters for all defaults). If the default values suit requirements, programming is not necessary.

Setting Parameters To set feature values, scan a single bar code or a short bar code sequence. The settings are stored in non-volatile memory and are preserved even when the scanner powers down. NOTE Most computer monitors allow scanning bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where you can see the bar code clearly, and bars and/or spaces do not merge.

To return all features to default values, scan Set Factory Defaults on page 5-5. Throughout the programming bar code menus, asterisks (*) indicate default values.

* Indicates default

*Enable Parameter

Feature/option

Scanning Sequence Examples In most cases scanning one bar code sets the parameter value. For example, to set the USB keystroke delay to medium, scan the Medium Delay (20 msec) bar code under USB Keystroke Delay on page 7-7. The scanner issues a fast warble beep and the LED turns green, signifying a successful parameter entry. Other parameters require scanning several bar codes. See the parameter descriptions for this procedure.

Errors While Scanning Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.

Page 96

7 - 2 DS2208 Digital Scanner Product Reference Guide

Connecting a USB Interface

USB series A shielded connector

Figure 7-1

Interface cable

USB Connection.

NOTE If you already have existing non shielded cables from legacy products (such as the LS2208) they can be reused. However, be aware that the shielded cables provide improved ESD performance. For regional information about cables and cable compatibility, go to the Zebra Partner Portal at: https://partnerportal.zebra.com/PartnerPortal/product_services/downloads_z/barcode_scanners/Universa l-Cable-Guide-Bar-Code-Scanners.xlsx.

The scanner connects to USB-capable hosts including: • TGCS (IBM) terminals • Apple™ desktop and notebooks • Other network computers that support more than one keyboard. The following operating systems support the scanner through USB: • Windows® XP, 7, 8, 10 • MacOS 8.5 - MacOS 10.6 • IBM 4690 OS. The scanner also interfaces with other USB hosts that support USB Human Interface Devices (HID).

Page 97

USB Interface 7 - 3

To set up the digital scanner: NOTE Interface cables vary depending on configuration. The connectors illustrated in Figure 7-1 are examples only. The connectors may be different than those illustrated, but the steps to connect the digital scanner are the same.

1.

Connect the modular connector of the USB interface cable to the cable interface port on the digital scanner (see Installing the Interface Cable on page 1-3).

2.

Plug the series A connector in the USB host or hub, or plug the Plus Power connector in an available port of the IBM SurePOS terminal.

3.

The digital scanner automatically detects the host interface type and uses the default setting. If the default (*) does not meet your requirements, select another USB device type by scanning the appropriate bar code from USB Device Type on page 7-5.

4.

On first installation when using Windows, the software prompts to select or install the Human Interface Device driver. To install this driver, provided by Windows, click Next through all the choices and click Finished on the last choice. The digital scanner powers up during this installation.

5.

To modify any other parameter options, scan the appropriate bar codes in this chapter.

If problems occur with the system, see Troubleshooting on page 4-3.

USB Parameter Defaults Table 7-1 lists the defaults for USB host parameters. Change these values in one of two ways: • Scan the appropriate bar codes in this chapter. The new value replaces the standard default value in memory. To recall default parameter values, see Default Parameters on page 5-5. • Configure the scanner using the 123Scan2 configuration program. See Chapter 2, 123Scan and Software Tools. NOTE See Appendix A, Standard Default Parameters for all user preferences, symbologies, and miscellaneous default parameters.

Table 7-1

USB Interface Parameter Defaults Parameter

Default

Page Number

USB Host Parameters USB Device Type

USB Keyboard HID

7-5

Symbol Native API (SNAPI) Status Handshaking

Enable

7-7

USB Keystroke Delay

No Delay

7-7

USB CAPS Lock Override

Disable

7-8

Bar Codes With Unknown Characters

Enable

7-8

USB Convert Unknown to Code 39

Disable

7-9

USB Fast HID

Enable

7-9

USB Polling Interval

3 msec

7-10

Page 98

7 - 4 DS2208 Digital Scanner Product Reference Guide

Table 7-1

USB Interface Parameter Defaults (Continued) Parameter

Default

Page Number

Keypad Emulation

Enable

7-12

Quick Keypad Emulation

Enable

7-12

Keypad Emulation with Leading Zero

Enable

7-13

USB Keyboard FN1 Substitution

Disable

7-13

Function Key Mapping

Disable

7-14

Simulated Caps Lock

Disable

7-14

Convert Case

None

7-15

CDC Beep on <BEL>

Enable

7-16

USB Static CDC

Enable

7-15

TGCS (IBM) USB Direct I/O Beep

Honor

7-16

TGCS (IBM) USB Beep Directive

Ignore

7-17

TGCS (IBM) USB Bar Code Configuration Directive

Ignore

7-17

TGCS (IBM) USB Specification Version

Version 2.2

7-18

Page 99

USB Interface 7 - 5

USB Host Parameters USB Device Type Scan one of the following bar codes to select the USB device type. To select a country keyboard type for the USB Keyboard HID host, see Appendix B, Country Codes. NOTES

1.

When changing USB Device Types, the scanner resets and issues the standard startup beep sequences.

2.

When connecting two scanners to a host, IBM does not allow selecting two of the same device type. If you require two connections, select IBM Table-Top USB for one scanner and IBM Hand-Held USB for the second scanner.

3.

Select IBM Hand-Held USB to disable data transmission when an IBM register issues a Scan Disable command. Aim, illumination, and decoding is still permitted. Select OPOS (IBM Hand-Held with Full Disable) to completely shut off the scanner when an IBM register issues a Scan Disable command, including aim, illumination, decoding, and data transmission.

*USB Keyboard HID

IBM Table-Top USB

IBM Hand-Held USB

OPOS (IBM Hand-Held with Full Disable)

Page 100

7 - 6 DS2208 Digital Scanner Product Reference Guide

USB Device Type (continued) NOTES

1.

Before scanning USB CDC Host, install the appropriate USB CDC Driver on the host to ensure the scanner does not stall during power up (due to a failure to enumerate USB). Go to www.zebra.com/support, Support & Downloads > Barcode Scanners > USB CDC Driver, select the appropriate Windows platform, and download either Zebra_CDC_ACM_Driver_(x64)v2.15.0004.exe (64 bit) or Zebra_CDC_ACM_Driver(x86)_v2.15.0004.exe (32 bit). To recover a stalled scanner: Install the USB CDC Driver or Unplug the USB cable and then reconnect it to add power back to the scanner. Scan HID Keyboard or another host. After power-up, hold the trigger for 10 seconds, which allows the digital scanner to power up using an alternate USB configuration. Upon power-up, scan another USB Device Type.

2.

To select the Toshiba TEC device type, refer to the Toshiba TEC Programmer’s Guide.

3.

Select USB HID POS to communicate over a USB cable with Universal Windows Platform (UWP) applications running on Windows 10 devices.

USB CDC Host

SSI over USB CDC

Symbol Native API (SNAPI) with Imaging Interface

Symbol Native API (SNAPI) without Imaging Interface

USB HID POS (for Windows 10 devices only)

Page 101

USB Interface 7 - 7

Symbol Native API (SNAPI) Status Handshaking After selecting a SNAPI interface as the USB device type, scan one of the following bar codes to select whether to enable or disable status handshaking.

*Enable SNAPI Status Handshaking

Disable SNAPI Status Handshaking

USB Keystroke Delay Scan one of the following bar codes to set the delay, in milliseconds, between emulated keystrokes. Select a longer delay for hosts that require slower data transmission.

*No Delay

Medium Delay (20 msec)

Long Delay (40 msec)

Page 102

7 - 8 DS2208 Digital Scanner Product Reference Guide

USB CAPS Lock Override This option applies only to the USB Keyboard HID device. Scan Override Caps Lock Key to preserve the case of the data regardless of the state of the Caps Lock key. This setting is always enabled for the Japanese Windows (ASCII) keyboard type and can not be disabled.

Override Caps Lock Key (Enable)

*Do Not Override Caps Lock Key (Disable)

Bar Codes with Unknown Characters This option applies only to the USB Keyboard HID and IBM devices. Unknown characters are characters the host does not recognize. Scan Send Bar Codes With Unknown Characters to send all bar code data except for unknown characters. The scanner issues no error beeps. Scan Do Not Send Bar Codes With Unknown Characters for IBM devices to prevent sending bar codes containing at least one unknown character to the host, or for USB Keyboard HID devices to send the bar code characters up to the unknown character. The scanner issues an error beep.

*Send Bar Codes with Unknown Characters

Do Not Send Bar Codes with Unknown Characters

Page 103

USB Interface 7 - 9

USB Convert Unknown to Code 39 This option applies only to the IBM Hand-Held, IBM Table-Top, and OPOS devices. Scan one of the following bar codes to enable or disable converting unknown bar code type data to Code 39.

Enable Convert Unknown to Code 39

*Disable Convert Unknown to Code 39

USB Fast HID Scan Enable USB Fast HID to transmit USB HID data at a faster rate. NOTE Disable this if there are problems with transmission.

*Enable USB Fast HID

Disable USB Fast HID