The text of a manual · part 13 of 48
DS2208 Digital Scanner Product Reference Guide: Chapter 6 Signature Capture Preferences
Pages 89 to 94 of 404, from DS2208 Digital Scanner Product Reference Guide
The original document is the PDF (12 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Zebra DS2208
Page 89
CHAPTER 6 SIGNATURE CAPTURE PREFERENCES Introduction You can program the digital scanner to perform various functions, or activate different features. This chapter describes signature capture preference features and provides programming bar codes for selecting these features. The digital scanner ships with the settings shown in Table 6-1 on page 6-2 (also see Appendix A, Standard Default Parameters for all defaults). If the default values suit requirements, programming is not necessary. NOTE Although the DS2208 digital scanner supports signature capture, the quality of the image is not guaranteed. If the image does not meet your needs it is recommended that you upgrade to a DS4308 or DS8108 scanner.
Setting Parameters To set feature values, scan a single bar code or a short bar code sequence. The settings are stored in non-volatile memory and are preserved even when the imager powers down. NOTE Most computer monitors allow scanning bar codes directly on the screen. When scanning from the screen, be sure to set the document magnification to a level where you can see the bar code clearly, and bars and/or spaces do not merge.
To return all features to default values, scan the Set Factory Defaults on page 5-5. Throughout the programming bar code menus, asterisks (*) indicate default values.
* Indicates default
*Enable Parameter (1)
Feature/option Option value
Page 90
6-2
DS2208 Digital Scanner Product Reference Guide
Scanning Sequence Examples In most cases scanning one bar code sets the parameter value. For example, to enable signature capture, scan the Enable Signature Capture bar code under Signature Capture on page 6-3. The digital scanner issues a fast warble beep and the LED turns green, signifying a successful parameter entry. Other parameters require scanning several bar codes. See the parameter descriptions for this procedure.
Errors While Scanning Unless otherwise specified, to correct an error during a scanning sequence, just re-scan the correct parameter.
Signature Capture Preferences Parameter Defaults Table 6-1 lists defaults for image capture preference parameters. Change these values in one of two ways:
• Scan the appropriate bar codes in this chapter. The new value replaces the standard default value in memory. To recall default parameter values, see Default Parameters on page 5-5.
• Configure the scanner using the 123Scan2 configuration program. See Chapter 2, 123Scan and Software Tools. NOTE See Appendix A, Standard Default Parameters for all user preference, host, symbology, and miscellaneous default parameters.
See Appendix K, Signature Capture Code for signature capture code information.
Table 6-1
Signature Capture Preferences Parameter Defaults Parameter
Parameter Number 1
SSI Number 2
Default
Page Number
Signature Capture Preferences Signature Capture
93
5Dh
Disable
6-3
Signature Capture Image File Format Selection
313
F0h 39h
JPEG
6-4
Signature Capture Bits per Pixel (BPP)
314
F0h 3Ah
8 BPP
6-5
Signature Capture Width
366
F4h F0h 6Eh
400
6-6
Signature Capture Height
367
F4h F0h 6Fh
100
6-6
Signature Capture JPEG Quality
421
F0h A5h
65
6-6
1. Parameter number decimal values are used for programming via RSM commands. 2. SSI number hex values are used for programming via SSI commands.
Page 91
Signature Capture Preferences
6-3
Signature Capture Preferences The parameters in this chapter control signature capture characteristics.
Signature Capture Parameter # 93 SSI # 5Dh A signature capture bar code is a special-purpose symbology which delineates a signature capture area in a document with a machine-readable format. The recognition pattern is variable so it can optionally provide an index to various signatures. The region inside the bar code pattern is considered the signature capture area. See Appendix K, Signature Capture Code for more information. Scan one of the following bar codes to enable or disable Signature Capture.
Enable Signature Capture (1)
*Disable Signature Capture (0)
Page 92
6-4
DS2208 Digital Scanner Product Reference Guide
Signature Capture File Format Selector Parameter # 313 SSI # F0h 39h Scan one of the following bar codes to select a signature file format appropriate for the system (BMP, TIFF, or JPEG). The imager stores captured signatures in the selected format.
Output File Format Decoding a signature capture bar code de-skews the signature image and converts the image to a BMP, JPEG, or TIFF file format. The output data includes the file descriptor followed by the formatted signature image.
Table 6-2
Output File Format File Descriptor
Output Format (1 byte) JPEG - 1 BMP - 3 TIFF - 4
Signature Type (1 byte)
Signature Image Size (4 bytes) (BIG Endian)
1-8
0x00000400
Signature Image
0x00010203….
BMP Signature Format (3)
*JPEG Signature Format (1)
TIFF Signature Format (4)
Page 93
Signature Capture Preferences
6-5
Signature Capture Bits Per Pixel Parameter # 314 SSI # F0h 3Ah Scan one of the following bar codes to select the number of significant bits per pixel (BPP) to use when capturing a signature:
• 1 BPP - For a black and white image. • 4 BPP - Assigns 1 of 16 levels of grey to each pixel. • 8 BPP - Assigns 1 of 256 levels of grey to each pixel. NOTE The imager ignores these settings for JPEG file formats, which only support 8 BPP.
1 BPP (0)
4 BPP (1)
*8 BPP (2)
Page 94
6-6
DS2208 Digital Scanner Product Reference Guide
Signature Capture Width Parameter # 366 SSI # F4h F0h 6Eh The aspect ratio of the Signature Capture Width and Signature Capture Height parameters must match that of the signature capture area. For example, a 4 x 1 inch signature capture area requires a 4 to 1 aspect ratio of width to height. To set the width of the signature capture box, scan the Signature Capture Width bar code, and then scan four bar codes from Appendix G, Numeric Bar Codes corresponding to a value in the range of 001 to 640 decimal.
Signature Capture Width (Default: 400) (001 - 640 Decimal)
Signature Capture Height Parameter # 367 SSI # F4h F0h 6Fh To set the height of the signature capture box, scan the Signature Capture Height bar code, and then scan three bar codes from Appendix G, Numeric Bar Codes corresponding to a value in the range of 001 to 480 decimal.
Signature Capture Height (Default: 100) (001 - 480 Decimal)
Signature Capture JPEG Quality Parameter # 421 SSI # F0h A5h Scan the JPEG Quality Value bar code, and then scan three bar codes from Appendix G, Numeric Bar Codes corresponding to a value from 005 to 100, where 100 represents the highest quality image.