The text of a manual · part 3 of 6
Barcode Anything CCD and Wedge Wand User's Guide, pages 21 to 30
Pages 21 to 30 of 60
The original document is the PDF (620 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Zebra CF-2KBW
Page 21
Chapter 3, Configuration Bar Code Controls & Configuration Why you might need to configure the CCD or Wedge Wand In order to enable the CCD and wedge wand to read any of the non-default settings for a bar code, they first must be configured. When the CCD and wedge wand are initially connected to your computer, it is not necessary to tell the CCD and wedge wand what type of bar code you would like them to read. Both have been preprogrammed at the factory to read Code 39 (standard or full ASCII), UPC/EAN/JAN (in all lengths and variations), Interleaved 2 of 5, Code 128, Codabar, MSI/Plessey, and Code 32. If you would like the CCD and wedge wand to read only one bar code format, for example, or to use settings other than those set as the default, you will need to reprogram the settings. However, before you can reprogram the settings, you need to be familiar with the setup procedure. Following are two examples: Example 1: Setup Code 39 Control →
Place command to CCD
→
Turn on Code 39 decoding
→
Code 39 Full ASCII mode selected
→
Code 39 mode 43
→
Setting procedure completed
Note: Please see page 23, which lists the bar codes that are used to complete the Code 39 Control configuration sequence. Barcode Anything® CCD and Wedge Wand User’s Guide
15
Page 22
Example 2: Set Prefix Begin
→
Place command to CCD
Prefix
→
Turn on Prefix setting
Appendix B "4"
Create Prefix A
Appendix B "1" SET End
→
Set up completed
→
Procedure completed
Note: Please see page 40, which lists the bar codes that are used to complete the Set Prefix configuration sequence. The default settings (indicated by a “*” symbol) will be overwritten when the CCD is programmed. Detailed set-up parameters are provided on the following pages. All of the programmed settings will be stored in the EEPROM, which is retained all of the time.
16
Barcode Anything® CCD and Wedge Wand User’s Guide
Page 23
Set Default Configuration
Begin
Default All programmed settings will be returned to the manufacturer default setting after the scanning process.
List Configurations Note: The below bar codes can be scanned individually and independently from those listed in Set Default Configuration above. Other available options
Show configuration
Show version
Start up code If the CCD’s light is on but it does not seem to be reading, scan the “Start up code”. This should reactivate the CCD.
Note: The Start up code listed above is for the CCD only.
Barcode Anything® CCD and Wedge Wand User’s Guide
17
Page 24
Keyboard Wedge Setting
Begin
*On Upper/Lower case
Upper
*Lower
End
Note: To successfully complete the above configuration process, you must scan the “End” bar code. You can control the Caps Lock function by engaging the Caps Lock key on your keyboard or by programming the CCD as described above. Programming the CCD enables you to override the keyboard Caps Lock key, allowing the use of lowercase or upper/lowercase characters even when the Caps Lock key is engaged.
18
Barcode Anything® CCD and Wedge Wand User’s Guide
Page 25
CCD Scanning Control
Begin Type
LED Light On-with button pressed Off-with button depressed
Bar Code One bar code
On-for 3 seconds Off-any bar code scanned
One bar code
On-with button pressed, light on for 3 seconds Off-with button pressed again
One bar code
On-all the time Off-never off
One bar code
On-for 30 seconds Off-automatically after 30 seconds or button pressed again
One bar code
On-for 120 seconds Off-automatically after 120 seconds or button pressed again
One bar code
Trigger pressed
*Trigger on
Trigger on/off
LED on
Trigger on 30 sec.
Trigger on 120 sec.
Note: CCD Scanning Control is continued on the next page.
Barcode Anything® CCD and Wedge Wand User’s Guide
19
Page 26
Continuous reading
On-all the time Off-never off or trigger off Safety time default value is 1 sec.
Same bar code Continuous read
Scan “Begin”+“Safety time”+ “0”+“8”+“Set”+“End” Set value is 0.8 sec.
Safety time 0.8 sec.
Safety time setting
End
Note: To successfully complete the above configuration process, you must scan the “End” bar code.
20
Barcode Anything® CCD and Wedge Wand User’s Guide
Page 27
Turn On Various Bar Code Formats
Begin OFF
ON Code 39*
*Interleaved 2 of 5
*Industrial 2 of 5
*Matrix 2 of 5
Codabar*
EAN-13*/UPC-A*
EAN-8*
UPC-E*
Note: Turn on Various Bar Code Formats is continued on the next page.
Barcode Anything® CCD and Wedge Wand User’s Guide
21
Page 28
OFF
ON *EAN/UPC Add-on 2/5
Code 128*
Code 11*
*MSI/Plessey
*China Postal Code
*Telepen
*Code 93
End
Note: To successfully complete the above configuration process, you must scan the “End” bar code.
22
Barcode Anything® CCD and Wedge Wand User’s Guide
Page 29
Code 39 Control
Begin
Off
*On Code 32 Control
*Off
On CIP 39 Control
*Off
On
*Standard type Full ASCII Transmit start/stop character
*No
Yes Verify checksum
*No
Yes Transmit check character
No
*Yes
End
Note: To successfully complete the above configuration process, you must scan the “End” bar code. Barcode Anything® CCD and Wedge Wand User’s Guide
23
Page 30
Interleaved 2 of 5 Control
Begin
*Off
On Transmit check digit
No
*Yes Verify checksum
*No
Yes
End
Note: To successfully complete the above configuration process, you must scan the “End” bar code.