Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 2 of 6

Barcode Anything CCD and Wedge Wand User's Guide, pages 11 to 20

Pages 11 to 20 of 60

The original document is the PDF (620 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Zebra CF-2KBW

Page 11

Configuration Chart To program the CCD or wedge wand to read settings other than the defaults, turn to Chapter 3 – Configuration, beginning on page 15 and select the options as explained in each section. Note: Starred (*) items indicate default settings. The CCD reader and wedge wand are normally programmed as a keyboard wedge for IBM's AT and compatibles or PS/2 models.

Operation, CCD To turn on the CCD, push the switch depress button located on the under side of the CCD. Red LED illumination will emit from the read window. The CCD reads all bar code symbologies listed in Chapter 3 – Configuration. Note: The CCD will not read any bar code that is wider than the read window. 1.

Touch the bar code label with the read window of the CCD.

2.

Read within a distance of 0 to 1.5 cm (approximately 9/16 inches) from the bar code label.

3.

Center the CCD read window over the bar code label for the fastest read.

4.

The CCD will beep to indicate a good read.

5.

A red LED indicator light will visually signal a good read.

Note: During the configuration process, if there is an “End” bar code you must scan it to successfully complete the configuration sequence; if there is not an “End” bar code then the configuration sequence does not require it. Barcode Anything® CCD and Wedge Wand User’s Guide

5

Page 12

When you scan a “Default” or “End” bar code during the configuration process, you will hear a beep, then a slight pause, then another beep. This final beep signals the configuration sequence has been completed successfully. If you try to scan a bar code after the sequence has been completed and no characters appear on your computer screen, scan “End”. Again, listen for the beep-pause-beep.

Operation, Wedge Wand The wedge wand is immediately capable of reading once it has been connected properly to the host computer. It can read all bar code formats listed in Chapter 3 – Configuration. 1.

A red LED will be seen in the window when power is supplied to the wedge wand.

2.

There is no bar code length limit as with other readers.

3.

Holding the wedge wand vertically to the scanning surface, drag the tip of the wedge wand across the bar code from beginning to end, either left to right or right to left, with the tip of the wedge wand touching the surface.

4.

Apply a moderate, even scan speed as you drag with the wedge wand, if you drag the wedge wand too fast, it will not read the entire bar code.

Note: During the configuration process, if there is an “End” bar code you must scan it to successfully complete the configuration sequence. A beep, then a slight pause, then another beep signals successful completion of the configuration process after you scan “End” or “Default”. If you try to scan a bar code after the sequence has been completed and no characters appear on your computer screen, scan “End” and listen for the beep-pause-beep. 6

Barcode Anything® CCD and Wedge Wand User’s Guide

Page 13

Keyboard Speed Settings For some application programs and compatibles, the CCD and wedge wand may send data faster than the computer or application program can accept. This is called "keyboard buffer overrun." If data appears to be missing, random read errors occur, or the CCD locks up and will not scan, then experiment with the various keyboard timing options listed below. These options will change the data transmission rate from the CCD to the host computer. Keystroke/Character

Begin

*Fastest

Fast

Medium

Slowest

Slow

End

Note: To successfully complete the above configuration process, you must scan the “End” bar code.

Barcode Anything® CCD and Wedge Wand User’s Guide

7

Page 14

Prefix Prefix is the data string automatically added prior to the bar code data during data transmission to the computer. Please see Set Prefix on page 40 for additional information.

Suffix Suffix is the data string automatically added after the bar code data but before the termination character during data transmission to the computer. Please see Set Suffix on page 41 for additional information.

Wedge Interface (Wedge Wand Only) The wedge wand is comprised of an intelligent decoder unit and a perfect-sensitization pen, in separate components. The wedge wand is compatible with virtually any application program accepting keyboard input.

Symbology Selection The CCD and wedge wand auto-discriminate all bar code symbologies. However, they can also be programmed to read only one bar code symbology, thus preventing the wedge wand from wasting time looking for other possibilities. If your application uses only one symbology, then program the CCD and wedge wand to read only that symbology. This will allow you to achieve a faster read rate and reduce the possibility of read errors (see Chapter 3 – Configuration beginning on page 15).

8

Barcode Anything® CCD and Wedge Wand User’s Guide

Page 15

Symbology Additions If the CCD is not programmed to meet your specific requirements, you can easily add different bar code symbologies. Please consult the many options listed in Chapter 3 – Configuration, beginning on page 15 of this user’s guide.

User Maintenance 1.

Cleaning the read window (the tip of the wedge wand) is the only maintenance that is required.

2.

Do not allow any abrasive material to touch the read window.

3.

Remove any dirt particles with a damp cloth.

4.

Clean the window using a soft cloth or cotton swab moistened with water.

Barcode Anything® CCD and Wedge Wand User’s Guide

9

Page 16

(This page left blank intentionally)

10

Barcode Anything® CCD and Wedge Wand User’s Guide

Page 17

Chapter 2, Installation Keyboard Wedge Scanner (Part # 43995)

* * * WARNING * * * Turn off the power to your computer and your main devices before installing your CCD Bar Code Scanner. The CCD has a built-in intelligent decoder unit and interface to connect directly to the keyboard interface of the computer without the need for a separate decoder box. Scanned bar code labels will appear to the system as if the data was entered from the keyboard. A connection cable is provided for installation. The scanner is installed or "wedged" between the keyboard and the computer. 1.

2.

Make certain you use the correct converter cable for the keyboard wedge. There are two types of cables included: Type

Part No.

PC/AT

43993

PS/2

43994

After the connections have been made (see Figure 1), turn on the computer. A beep indicates it is working and installation is completed.

Barcode Anything® CCD and Wedge Wand User’s Guide

11

Page 18

The keyboard wedge connects as shown below (see Figure 1): 1.

Connect #5 (D-Sub 6-pin male connector) to #2 (D-Sub 5-pin female connector). Then plug #5 into the host computer port.

2.

Connect #4 (D-Sub 6-pin female connector) to #3 (D-Sub 5-pin male connector). Then plug #4 into the keyboard.

Note: If your computer is a PC/AT model, you will not have to connect the 6-pin connectors to the 5-pin connectors; you can simply plug the DSub 5-pin male connector (#3) directly into the computer port and the D-Sub 5-pin female connector (#2) directly into the keyboard. (1) CCD Bar Code Scanner

(4) D-Sub 6-pin Connector (female) (3) D-Sub 5-pin Connector (male)

(5) D-Sub 6-pin Connector (male) (2) D-Sub 5-pin Connector (female)

Figure 1: Connecting the Keyboard Wedge Scanner

12

Barcode Anything® CCD and Wedge Wand User’s Guide

Page 19

Keyboard Wedge Cable (Part #43996)

* * * WARNING * * * Turn off the power to your computer and your main devices before installing your Wedge Wand. The keyboard wedge cable connects the following (see Figure 2): 1.

Wedge Wand

2.

Decoder

3.

Keyboard connection

4.

Host computer keyboard port

Figure 2: Connecting the Keyboard Wedge Cable

Barcode Anything® CCD and Wedge Wand User’s Guide

13

Page 20

Keyboard Wedge Connector Pin Assignments 1. IBM PC/AT (Part # 43993) Housing Function DSUB 9 (M) 1 VCC 9 2 GND 6 3 CLK (KB) 2 4 DAT (KB) 7&8 5 5 6 DAT (PC) 3 7 CLK (PC) 1 (M) = Male (F) = Female 2. IBM PS/2 Models (Part # 43994) Housing Function DSUB 9 (M) 1 VCC 9 2 GND 6 3 CLK (KB) 2 4 DAT (KB) 7&8 5 5 6 DAT (PC) 3 7 CLK (PC) 1

14

DIN 5 (M) 5 4

3 2 1

DIN 6 (M) 4 3

2 1 5

DIN 5 (F) 5 4 1 2 3

DIN 6 (F) 4 3 5 1 2

Barcode Anything® CCD and Wedge Wand User’s Guide