Page 11

Keyboard wedge Keyboard Layout: The selecting of keyboard layout supports many country languages other than USA keyboard layout. First you need to confirm country language that you desire. In DOS, using command “keyb” to select the desirable keyboard layout or in WINDOWS entry “Control” then pops “Keyboard” to select country at “language” item. For details, please refer to your DOS or WINDOWS user’s manual. Keyboard Speed: By selecting, you can change output speed of scanner to match with host computer. Generally, set 00 or 01 in working high speed. If some output characters of barcode have been lost, you may need to set 05 or 06 to match your host keyboard speed. Function Key: Set Enable, scanner can output code as pressing function-key in your application program while the barcode datas contain ASCII value between 0116 to 1F16. Refer to ASCII table, page 94. Numeric Key: The Keypad has to be selected if your application program is only keypad numeric code acceptable. So, scanner will output code as press numeric keypad when it read numeric digit. (The keypad is in the right side of keyboard, and Num Lock control key is also on.) If Alt+Keypad is selected, Caps Lock and output will be independent.

Program Option Bar Code

Option

Alphanumeric Entry

11

Page 12

Keyboard layout

Keyboard speed

USA

00*

Belgium

01

Danish

02

France

03

Germany

04

Italian

05

Portuguese

06

Spanish

07

Swedish

08

Switzerland

09

UK

10

Latin American

11

0-8

00-08

0 : high clock rate

01*

8 : low clock rate Disable

00

Enable

01*

Alphabetic key

00*

Numeric keypad

01

Function key

Numeric key

(Num lock state only) Alt+Keypad

02

Exit

12

Page 13

Keyboard wedge Caps Lock: By selecting Caps Lock or No Caps Lock, scanner can get Caps Lock status. Power-on simulation: All of the PCs check the keyboard status during power-on selftest. It is recommended to Enable function if you are working without keyboard installation. It simulates keyboard timing and pass keyboard present status to the PC during power-on. Inter-character delay: This delay is inserted after each data characters transmitted. If the transmission speed is too high, the system may not be able to receive all characters. Adjust it and try out suited delay to make system work properly. Block transmission delay: It is a delay timer between barcode data output. The feature is used to transfer continually with shorter barcode data or multi-field scanning.

13

Page 14

Program Option Bar Code

Option

Alphanumeric Entry

Caps lock”ON”

00

Caps lock”OFF”

01*

Disable

00*

Enable

01

00-99 msec

00-99

Caps lock

Power-on simulation

02* Inter-character delay 00-99 10 msec

00-99 10*

Block transmission delay

Exit

14

Page 15

RS-232 CTS: Clear To Send (Hardware Signal) RTS: Request To Send (Hardware Signal) Xon: Transmit On (ASCII Code 1116) Xoff: Transmit Off (ASCII Code1316) Flow control: None-The communication only uses TxD and RxD signals without regard for any hardware or software handshaking protocol. RTS/CTS-If the scanner wants to send the barcode data to host computer, it will issue the RTS signal first, wait for the CTS signal from the host computer, and then perform the normal data communication. If there is no replied CTS signal from the host computer after the timeout

(Response Delay)

duration, the scanner will issue a 5 warning beeps. Xon/Xoff- When the host computer is unable to accept data, it sends a Xoff code to inform the scanner to suspend data transmission, and Xon to continue. ACK/NAK- When the ACK/NAK protocol is used, the scanner waits for an ACK (acknowledge) or (not acknowledge) from the host computer after data transmission, and will resend in response to a NAK. Inter-character delay: It is delay time between data character’s data output. It is also same as Inter-char. delay of keyboard wedge. Block transmission delay: It is a delay time between barcode data output. It is also same as Block transmission delay of keyboard wedge. Response delay: This delay is used for serial communication of the scanner to waiting for handshaking acknowledgment from the host computer.

15

Page 16

Program Option Bar Code

Option

Alphanumeric Entry

Flow control

None

00*

RTS/CTS

01

Xon/Xoff

02

ACK/NAK

03

00-99 (msec)

00-99 00*

Inter-character delay 00-99 (10 msec)

00-99 00*

Block transmission delay 00-99 (100 msec)

00-99 20*

Response delay

Exit

16

Page 17

Program Option Bar Code

Option

Alphanumeric Entry

Baud rate

Parity

300 BPS

00

600 BPS

01

1200 BPS

02

2400 BPS

03

4800 BPS

04

9600 BPS

05*

19200 BPS

06

38400 BPS

07

None

00*

Odd

01

Even

02

8 bits

00*

7 bits

01

One bit

00*

Two bits

01

Data bit

Stop bit

Exit

17

Page 18

Wand Emulation Bar/space polarity: High/low- Black will be transmitted as a high voltage level (+5) and space as low level (0V). Low/high- Black will be transmitted as a low voltage level (0V) and space as high level (+5). Initial polarity: You must make sure what is Initial polarity of your wand decode device in stand-by (idle). So, initial signal state as a High voltage level (+5) or Low voltage level (0V).

Program Option Bar Code

Option

Alphanumeric Entry

High/low

00*

Low/high

01

Low

00*

High

01

Bar/space polarity

Initial polarity

Exit

18

Page 19

Wand Emulation Output speed: This setting is same as serial transmission baud rate, and it must be approbated your wand decode resolution. The unit of speed is a width of minimum narrow bar. Margin delay: It is a timer of zone like space zone of barcode label margin. The width of margin time will be added before and after in each barcode data automatically when it is transmitted. Transmit delay: It is a delay time between barcode data output. It is the same as Block transmission delay of keyboard wedge.

Program Option Bar Code

Option

Alphanumeric Entry

Output speed

620 pps

00

1250 pps

01

2500 pps

02

5000 pps

03*

10000 pps

04

20000 pps

05

*pps: pixel per second

19

Page 20

00*

Reserved 00*

Reserved 00-99 (10 pixel)

00-99 15*

Margin delay 00-99 (10 msec)

00-99 30*

Transmit delay

Exit

20