Page 1

ZB-8150/ZB-8110/ZB-8210

CCD BARCODE SCANNER

User’s Manual

ZBA Inc 94 Old Camplain Road Hillsborough NJ 08844 Phone: 908-359-2070 Fax: 908-359-1272 Web: http://www.zbausa.com/

1

Page 2

Installation: Keyboard Wedge 1) 2) 3) 4) 5)

Turn off the PC Disconnect the keyboard cable from the PC. Connect the Keyboard Cable to the scanner and connect the scanner cable to the PC Turn the terminal/computer power on. You are ready use the scanner

RS-232 1) 2) 3) 4) 5)

Turn off the PC. Connect the Scanner cable to the PC. Plug the power supply to the scanner Plug the power pack into power source. Turn on PC, You are ready to use the scanner

USB (with HID Keyboard Interface) 1) 2)

Plug the USB cable to PC. (some USB hub may have power problem, Check with HUB manufacturer) Follow the instruction to install windows driver come with your windows operating system.

Note: The scanner may not work with windows 95 or windows 98 first edition.

2

Page 3

Default Setting for each barcode shown as below: Code Type UPC-A UPC-E EAN-13 EAN-8 Code-39 Interleaved 2 of 5 Industrial 2 of 5 Matrix 2 of 5 Codabar Code-128 Code-93 Code-11 MSI/Plessey UK/Plessey Telepen Standard 2 of 5 RSS-14 RSS-Limited RSS-Expanded China Post Italian Pharmaode. Code-16K PDF417

Read Enable

Checksum Checksum Code Verification Transmission ID Enable Enable 8110 8150/8210 V V V V V

V V V V V

V V V V

V

V

V

V

A E F FF

*

V V

V V V V i -

V V V One digit V V -

- i B % # & O @ @ S i R4 RL RX t p

-

V(8210)

3

-

Page 4

ZBA ZB- 8110 / 8150 - 1D Barcode scanner Specification

Model 8110

Model 8150

Operational Light Source

660 nm Visible Red LED

Optical System

2048 pixel CCD (Charge-coupled device)

Depth of Scan Field

0-80 mm

0-250 mm

(CODE 39,

(CODE 39,

PCS=90%, 20mils) PCS=90%, 20mils) Scanning Width

80 mm

120 mm

Scan Speed

50 scans/sec

200 scans/sec

Resolution

0.125mm(5mils)

0.1mm(4mils)

Code39,PCS=45%, Code39,PCS=90%, on contact Print Contrast Scanning Angle Decode Capability

30% or more Front: 60°

Rear: 60°

Yaw: 75°

Autodiscriminates all standard barcodes; Other symbologies can be ordered optionally

Beeper Operation

7 tones or no beep

Indicator

Green led

Mechanical Length

182 mm

Width-handle

26 mm

Width-head

90 mm

74 mm

Depth-handle

51 mm

Depth-head

35 mm

4

Page 5

Weight

155 g (cable not

160 g (cable not included)

included)

Cable – K/B wedge

Straight 2.0 m

Cable – universal

Straight 2.3 m type Connector type

RJ-45 phone jack connector

Case material

ABS plastic

Cushion material

Rubber

Electrical Input Voltage

5 VDC ± 0.25V

Power - Operating

380 mW

1275 mW

Power - Standby

240 mW

600 mW

Current - Operating

76 mA @ 5 VDC

255 mA @ 5 VDC

Current - Standby

48 mA @ 5 VDC

120 mA @ 5 VDC

DC Transformers

Class 2; 5VDC @ 450 mA

Agency listing

UL, FCC Class A

Environmental Operating Temperature

0℃ to 45℃ (32℉ to 113℉)

Storage

-40℃ to 60℃

Humidity

5% to 90% relative humidity,

(-40℉ to 140℉) non-condensing Light Level

Up to 15000 Lux

Up to 60000 Lux

Shock

1.0m drop onto

1.5m drop onto concrete concrete

Contaminants

Seals to resist airborne particulate contaminants

Ventilation

None required

5

Page 6

Programming Programming method

Manual (Reading special barcode) DOS command through RS-232, Windows configuration program

Program upgrade

Enabled by built-in flash memory

Programmable

Code type selection, check digit characteristics selection Decoding option Decoding option Transmitted character delay, Header selection, trailer selection, message suffix, good read beep tone and volume, scanner trigger selection Keyboard emulation type (intermessage delay, keyboard type and keyboard language) Serial interface type (ACK/NAK, Xon/Xoff, RTS/CTS, good read LED control, start/stop bits)

6

Page 7

Programming the 8110/8150/8210 To program the 8110/8150/8210, you must scan a series of programming barcode in the correct order. Fold out the back cover of this manual. You will see a table of alphanumeric barcodes, which are used to program the various options presented.

To program each option, you must: 1. Scan the Program barcode on the parameter setting part. 2. Enter the option mode by scanning the Option Bar Code (also on the Parameter setting part). 3. To the right of the option barcode, the necessary alphanumeric inputs are listed. Scan these alphanumeric entries from the back fold out page. To confirm above steps, you must scan the Finish barcode on the back fold out page. 4. Once you have finished programming. Scan the Exit barcode, listed on the lower right hand corner of each parameter setting part.

7

Page 8

Program Barcode Program

Option Bar Code

Option

Alphanumeric Entry

Keyboard Wedge

00*

Interface

RS-232

01 selection

Wand emulation

02

USB

03

Keyboard/RS-232

04

Auto detection reserved

05

Exit Option Barcode

Back Fold Out Exit Barcode

Finish barcode

8

Page 9

Interface Selection This decoder build-in scanner comes in one model and supports interfaces such as keyboard wedge, RS232 serial wedge, wand emulation, and the latest USB interface. In most of the cases, simply selecting an appropriate cable with a device code will work for a specific interface. Interface selection: You can change factory interface default for other type interface. By plugging different cables, setting right interface, then the scanner will be changed to another interface. However, you must make sure which cable you need. Keyboard/RS232/USB Auto detection: By setting this function, it will automatically select the Keyboard wedge or RS-232 or UBS interface for user.

Program Option Bar Code

Option

Alphanumeric Entry

Interface selection

Keyboard Wedge

00

RS-232

01

Wand emulation

02

USB

03

Keyboard /RS232/USB

04*

Auto detection Reserved

05

Note:*-Default

Exit

9

Page 10

Keyboard wedge As a keyboard interface, the scanner supports most of the popular PCs and IBM terminals. The installation of the wedge is a fairly simple process without any changes of software or hardware. Keyboard Type: Select keyboard type connector of your host computer. Scanner must be selected to the appropriate host interface cable converter.

Program Option Bar Code

Option

Alphanumeric Entry

Keyboard type

IBM AT, PS/2

00*

Reserved

01

Reserved

02

Reserved

03

Reserved

04

Reserved

05

Reserved

06

Exit

10