Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 7 of 17

Getting Started With MAXserver Access Servers, Models 1604, 1608A/B, 1620 and 1640, pages 61 to 70

Pages 61 to 70 of 164

The original document is the PDF (902 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Xyplex MX-1620

Page 61

Getting Started with MAXserver Access Servers

7-wire

X

NO

MAXserver 1100,1120,1500,1520, 1800, and 1820 Access Servers.

8-wire

X

X

MAXserver 800, 1600,1604, 1608, 1620, 1640 Access Servers. Network 9000 Access Server 720 RJ-45 I/O Modules (Model 723).

See the Modems section of the Basic Configuration Guide for information about modem control and setting up modems.

Modem Control/Hardware Flow Control MAXserver serial ports can be set up to support RTS/CTS flow control. The Basic Configuration Guide describes flow control options and explains how to set up flow control at a port. The adapters shown in Figure 13 and 13 support RTS/CTS flow control. MAXserver serial ports can also be set up to support modem control. The Basic Configuration Guide describes modem control options and explains how to set up modem control at a port. The adapter shown supports modem control, by supporting the RING signal.

0038

61

Page 62

Getting Started with MAXserver Access Servers

To use modem control or hardware flow control, you need an input control signal and an output control signal for each. This is important to consider when you decide which NBase-Xyplex unit to use for a particular application, since different NBase-Xyplex units support different wiring schemes, and some units might not have enough signals for the desired application. NBase-Xyplex cabling and software can be configured to use various combinations of modem control, and hardware flow control. There are two types of hardware flow control: DCD/DSR and RTS/CTS. DCD/DSR flow control (referred to here as "standard" hardware flow control) is the type that one would typically use with lower speed modems. RTS/CTS is used with high speed modems (typically, these modems support CCITT V.42 operation). Only one type of hardware flow control can be used at a given port. Modem control and DCD/DSR hardware flow control are mutually exclusive (i.e., only one of these can be enabled at a given port). On 8-wire interfaces, modem control can be used concurrently with RTS/CTS hardware flow control. NOTE:

You would use a "null-modem" cable when making a direct connection between the serial ports of two access servers (i.e., no modems involved) or other DTE device. For that application, use a DTE-to-DTE cable, as described in the hardware documentation supplied with your unit.

Making Your Own RJ-45 Cables If you make your own cables, you should be very careful when using the crimping tool. Make sure that the RJ-45 connector is fully inserted into the die-set cavity of the crimping tool, and that the wire is fully inserted into the RJ-45 connector, before crimping. The die set might be fragile, and could break if the RJ-45 connector is not properly seated before you squeeze the handle.

62

0038

Page 63

Getting Started with MAXserver Access Servers

Also, NBase-Xyplex recommends that you use different colored wires for straight-through and crossover cables, in order to keep track of the cable type. For example, NBase-Xyplex recommends silver wire for making crossover cables and black wire for making straight-through cables.

RJ-45 Wiring Considerations You should give special consideration to the wiring scheme when connecting a device such as a terminal to a MAXserver serial port. The MAXserver is considered a DTE device. If you want to connect to another DTE device such as a terminal that is also DTE, you will need a crossover wiring scheme somewhere in the cabling. (Communication between DTE-to-DTE devices requires a crossover.) When a DCE device is connected to a MAXserver serial port, straight-through wiring is required. To make a modular cable with a crossover, you need only crimp the RJ-45 connector in the same direction at both ends. This crosses all wires in the cable. To make a modular straight-through cable, you need only crimp the RJ-45 connector in opposite directions at both ends. Figure 12 shows the crossover and straight-through wiring schemes. The crossover connects the MAXserver transmit data (XMT) line to the receive data (RCV) line of the user DTE device. Similarly, the MAXserver receive data (RCV) line crosses over to the transmit data (XMT) line of the user DTE device. The other signals are crossed over in a similar manner (see Figure 12).

0038

63

Page 64

Getting Started with MAXserver Access Servers

RJ-45 Connectors

Crossover Cable

RJ-45 Connectors

Straight Through Cable

Figure 12 - Crossover and Straight-through Wiring Schemes

Modular Adapters (RJ-45 to DB-25) You can obtain adapters with male and female DB-25 connectors from NBase-Xyplex. These adapters direct signals from the RJ-45 connector on the cable to the correct pin on the DB-25 connector. Figure 13 and Figure 14 show how devices are cabled when you use these adapters.

Using Existing MAXserver 1000-series Cabling The adapters shown in Figure 13 and are designed for use with all MAXserver units. If you have existing MAXserver 1000-series cabling at your site, the cabling can be used to connect MAXserver ports to DTE devices -- provided you do not need to turn on RTS/CTS flow control at the ports. If you plan to connect the unit to a DCE device, you should use one of the adapters shown in Figure 14.

64

0038

Page 65

Getting Started with MAXserver Access Servers

MAXserver Connector

Modular Adaptor

DTE Cable

Crossover Cable Female

Male

Male

Female

RJ-45

RJ-45

RJ-45

RJ-45

Female

To DTE

DB-25

MAXserver Connector CTS/RING DTR XMT XMTGND RCVGND RCV DSR * RTS

1 2 3 4 5 6 7 8

Male RJ-45 Connector

Male RJ-45 Connector 1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

Female RJ-45 Connector

Female DB-25 Connector

1 2 3 4 5 6 7 8

DTE Device Pin Signal

5 20 2 7

CTS DTR XMT GND

3 8 6 4

RCV DCD DSR RTS

Crossover Cable

* (See Note, Page 5.)

Adaptor Wiring - MX-350-0181 (Female RJ-45 to female DB-25)

Figure 13 - Adapter Wiring, MAXserver to DTE

0038

65

Page 66

Getting Started with MAXserver Access Servers

MAXserver Connector

Modular Adaptor

Modem Cable

Straight Through Cable Female RJ-45

Male RJ-45

Male RJ-45

Female RJ-45

Male DB-25

To Modem

(a) Supports RING: MAXserver Connector CTS/RING 1 DTR 2 XMT 3 XMTGND 4 RCVGND 5 RCV 6 DCD * 7 RTS 8

Male RJ-45 Connector

Male RJ-45 Connector 1 2 3 4 5 6 7 8

1 2 3 4 5 6 7 8

Female RJ-45 Connector

Male DB-25 Connector

1 2 3 4 5 6 7 8

DCE Device Pin Signal

22 20 2 7

RING DTR XMT GND

3 8 4 5

RCV DCD RTS CTS

Straight Through Cable Adaptor Wiring - MX-350-0179 (Female RJ-45 to male DB-25)

(b) Supports RTS/CTS: MAXserver Connector

Male RJ-45 Connector

CTS/RING 1 DTR 2 XMT 3 XMTGND 4 RCVGND 5 RCV 6 DCD * 7 RTS 8

1 2 3 4 5 6 7 8

Male RJ-45 Connector 1 2 3 4 5 6 7 8

Female RJ-45 Connector

Male DB-25 DCE Device Connector Pin Signal

1 2 3 4 5 6 7 8

5 20 2 7

CTS DTR XMT GND

3 8 4

RCV DCD RTS

Straight Through Cable Adaptor Wiring - MX-350-0180 (Female RJ-45 to male DB-25)

Figure 14 - Adapter Wiring, MAXserver to DCE

66

0038

Page 67

Getting Started with MAXserver Access Servers

NOTES: In order to expand the functionality of the serial interface, the MAXserver modular cabling allows you to connect different signals to pin 7 of the MAXserver. (This pin is an input to the MAXserver.) When a DCE device is connected to a MAXserver serial port, the device's DCD output is connected to pin 7. In this case, the signal at pin 7 is referred to as DCD. When a DTE device is connected to a MAXserver serial port, the device's DTR output is connected to pin 7 of the MAXserver. In this case, the signal at pin 7 is referred to as DSR. (This cabling scheme also provides DECconnect compatibility, since DECconnect does not support the DCD signal.)

DEConnect RJ-45 Cables DEConnect cables no longer available. Figure 15 shows the DEConnect-compatible cables available from NBaseXyplex and shows how the cables are wired. The Male RJ-45 connector is attached to the server. The MMJ connector attaches to the DEConnectcompatible device (DTE). The cable is a crossover cable that uses the six inner pins of the server port and makes the signals available at the MMJ connector. The cable is constructed using standard six-wire cable.

0038

67

Page 68

Getting Started with MAXserver Access Servers

DEConnect Crossover Cable Male RJ-45 Connector

Male MMJ Connectors

1 RING/CTS 2 DTR 3 XMT 4 XMTGND 5 RCVGND 6 RCV 7 DSR/DCD 8 RTS

6 DSR 5 RCV 4 RCVGND 3 XMTGND 2 XMT 1 DTR

Figure 15 - MAXserver DEConnect Cable NOTE: If you have existing DEConnect cables that you want to use with the MAXserver, the one-foot straight through cable and the RJ-45 to MMJ adapter or modular adapter allow you to use these cables without making any changes. You can also use the male RJ-45 to female MMJ adapter.

Octopus Cables An octopus cable fans out a single 50-pin male or female Telco connector, or a 36-pin male or female Telco DEConnect connector, to eight male RJ-45 connectors. These cables enable you to connect a MAXserver's serial ports to existing wiring in your facility. For example, you can use octopus cables to connect the MAXserver's serial ports to a punch down block.

68

0038

Page 69

Getting Started with MAXserver Access Servers

Figure 16 shows an octopus cable with a 50-pin Telco connector: 6'

Eight male RJ-45 connectors

50-pin Telco connector (male or female)

Figure 16 - Octopus Cable with 50-pin Telco Connector Figure 17 shows an octopus cable with a 36-pin female Telco DEConnect connector. Figure 18 shows an octopus cable with a 36-pin male Telco DEConnect connector. 6'

36-pin female Telco DEConnectconnector

Eight male RJ-45 connectors

Figure 17 - Octopus Cable With 36-pin Female DEConnect Connector

0038

69

Page 70

Getting Started with MAXserver Access Servers

6'

36-pin male Telco DEConnect connector

Eight male RJ-45 connectors

Figure 18 - Octopus Cable With 36-pin Male DEConnect connector

Connecting to a Distribution Panel By using two types of octopus cable, you can connect MAXserver serial ports to a distribution panel that has DB-25 connectors. This enables you to adapt modular cabling to NBase-Xyplex TSERV-style cabling. NBase-Xyplex offers octopus cables that fan out a 50-pin Telco connector to 8 male or female DB25 connectors. These cables are available from NBase-Xyplex in 3', 10', and 50' lengths. You can connect the unit to the distribution panel via the two octopus cables as shown in Figure 19. (You might need an extension cable to connect the two cables.)

70

0038