Page 71
Getting Started with MAXserver Access Servers
Octopus cable: 8 DB-25 (male or female) to 50-pin male Telco
MAXserver 1620/1640
Octopus cable: 8 RJ-45 to 50-pin female Telco Distribution panel
Figure 19 - Connecting a MAXserver to DB-25 Distribution Panel
0038
71
Page 72
Getting Started with MAXserver Access Servers
NBase-Xyplex 6-Wire Cabling This cabling scheme provides XMT, RCV, DCD, DTR, RING, and ground wires. Using this cabling scheme you can use either modem control or hardware (DCD/DTR) flow control, but not both, since there are only three control signals. This scheme is useful for applications which have simple modem signalling requirements, such as:
·
Terminal emulation and file transfer applications (Kermit, Xmodem, Microphone, etc).
·
Applications such as SLIP and PPP using low speed modems.
Figure 20 depicts the wiring that you would use to connect the serial port of a NBase-Xyplex unit to a modem or other DCE device. For simplicity, modular cables are shown in the figure; but there are other wiring options available with this cabling scheme. (These are covered in more detail in the hardware documentation supplied with your unit.) You can purchase modular cables and adapters shown in the figure from NBase-Xyplex, or make your own cables based on the wiring diagram.
72
0038
Page 73
Getting Started with MAXserver Access Servers
Modular Adaptor Straight Through Cable
Communication
To Modem
Server Connector
Female RJ-12 Connector
Male RJ-12
Male RJ-12
Female RJ-12
Connector
Connector
Connector
1 2
1 2
DCD 3 RCV 4 GND 5
3 4 5
6
6
DTR XMT
RING
Male DB-25 Connector
Modem connector Pin Signal
1 2
20 •DTR 2 XMT
4 5
3 4 5
8 3
6
6
1 2 3
Straight Through Cable
DCD RCV
7 GND 22 RING 4 RTS 5
CTS
Adaptor Wiring - MX-350-0157 (Female RJ-12 to male DB-25)
Figure 20 - Modular Cables for Connecting a Modem (6-Wire) When using this cabling scheme, serial ports observe the DCD modem control signal rather than the DSR modem control signal for modem control, as well as DSRLOGOUT, SIGNAL CHECK, and hardware flow control applications. NBase-Xyplex 7-Wire Cabling This cabling scheme provides XMT, RCV, DCD/DSR, DTR, RING, and separate transmit and receive ground wires. This cabling is provided through RJ-45 connectors (pin 8 of the connector is not used). Using this cabling scheme you can use either modem control or hardware flow control, but not both, since there are only 3 control signals. This scheme is useful with the following applications:
·
0038
Terminal emulation and file transfer applications, such as Kermit, Xmodem, Microphone, etc.
73
Page 74
Getting Started with MAXserver Access Servers
·
Applications such as SLIP and PPP using low speed modems
·
Applications such as SLIP and PPP using high speed modems
Applications using CCITT V.42-compliant modems, or other devices operating at high port speeds. Figure 21 illustrates a wiring diagram that shows the needed cabling to connect an access server serial port to a modem for most standard applications (i.e., those which do not require RTS/CTS hardware flow control). Figure 22 shows the wiring for applications which require RTS/CTS flow control. You can purchase modular cables and adapters shown in the figure from NBase-Xyplex, or make your own cables based on the wiring diagram. Standard Modem Connection Communication Server Connector
Female RJ-45 Connector RING DTR XMT XMTGND RCVGND RCV DCD Not Used
1 2 3 4 5 6 7 8
Modular Adaptor
Straight Through Cable
To Modem
Male RJ-45 Connector
Male RJ-45 Connector
1 2 3 4 5 6 7 8
1 2 3 4 5 6 7 8
Female RJ-45 Connector
Male DB-25 Connector
1 2 3 4 5 6 7 8
Straight Through Cable
Modem connector Pin Signal
22 RING 20 •DTR 2 XMT 7 GND 3 8 6 4 5
RCV DCD DSR RTS CTS
Adaptor Wiring - MX-350-0187 (Female RJ-45 to male DB-25)
Figure 21 - Modular Cables for Connecting a Modem (7-Wire)
74
0038
Page 75
Getting Started with MAXserver Access Servers RTS/CTS Modem Connection Modular Adaptor Straight Through Cable
Communication Server Connector
Female RJ-45 Connector
To Modem
Male RJ-45 Connector
Male RJ-45 Connector
Female RJ-45 Connector
RING 1 DTR 2 XMT 3 XMTGND 4 RCVGND 5 RCV 6 DCD 7
1 2 3
1 2 3
1 2 3
4 5 6 7
4 5 6 7
8
8
8
4 5 6 7 8
Not Used
Male DB-25 Modem connector Connector Pin Signal 22 4 2
RING RTS XMT
7 3 5 20 6
GND
8
Straight Through Cable
RCV CTS DTR DSR DCD
Adaptor Wiring - MX-320-0211 (Flow Control)
Figure 22 - Modular Cables for RTS/CTS Flow Control (7-Wire) NBase-Xyplex 8-Wire Cabling This cabling scheme provides XMT, RCV, DCD/DSR, DTR, RTS, CTS/RNG, and separate transmit and receive ground wires. This cabling is provided through RJ-45 connectors. Using this cabling scheme you can concurrently use modem control and RTS/CTS hardware flow control, since there are four control signals. This scheme is useful with relatively high speed devices, complex modem control applications. In Figures 22 and 23, one signal is referred to as CTS/RING. The CTS/RING signal designation refers to the signal observed at pin 1 of each serial port. Pin 1 is multiplexed to these signals. Depending on the software configuration, you can use this pin as either CTS or RING, but not both at the same time.
0038
75
Page 76
Getting Started with MAXserver Access Servers
This scheme is useful with the following applications:
·
Terminal emulation and file transfer applications, such as Kermit, Xmodem, Microphone, etc.
·
Applications such as SLIP and PPP using low speed modems.
·
Applications such as SLIP and PPP using high speed modems.
·
Applications using CCITT V.42-compliant modems, or other devices operating at high port speeds.
·
AppleTalk Remote Access (ARAP) applications
Standard Modem Connection
Modular Adaptor
Straight Through Cable
Communication Server Connector
To Modem
Female RJ-45 Connector
Male RJ-45 Connector
CTS/RING 1 DTR 2 XMT 3 XMTGND 4 RCVGND 5 RCV 6 DCD 7 RTS 8
1 2 3
1 2 3
4 5 6 7 8
4 5 6 7 8
Male RJ-45 Connector
Female RJ-45 Connector
Modemconnector Male DB-25 Connector Pin Signal
1 2 3 4 5 6 7 8
22 20 2 7
RING DTR XMT GND
3 8 4 5
RCV DCD RTS CTS
Straight Through Cable Adaptor Wiring - MX-350-0179 (Female RJ-45 to male DB-25)
Figure 23 - Modular Cables for Connecting a Modem (Eight-Wire)
76
0038
Page 77
Getting Started with MAXserver Access Servers
RTS/CTS Modem Connection
Modular Adaptor
Straight Through Cable
Communication Server Connector
To Modem
Modemconnector Male DB-25 Connector Pin Signal
Female RJ-45 Connector
Male RJ-45 Connector
CTS/RING DTR XMT
1 2 3
1 2 3
1 2 3
1 2 3
5 20 2
XMTGND 4 RCVGND 5 RCV 6 DCD 7 RTS 8
4 5 6 7 8
4 5 6 7 8
4 5 6 7 8
7
CTS DTR XMT GND
3 8 4
RCV DCD RTS
Male RJ-45 Connector
Female RJ-45 Connector
Straight Through Cable Adaptor Wiring - MX-350-0180 (Female RJ-45 to male DB-25)
Figure 24 - Modular Cables for RTS/CTS Flow Control (Eight-Wire) NBase-Xyplex 3-Wire Cabling This cabling scheme provides XMT, RCV, and ground wires. This cabling scheme is used with NBase-Xyplex MX-TSERV-J16 and MX-TSRVL-J16 ACCESS SERVER cards. This wiring scheme can only be used for applications which do not require modem control signalling.
0038
77
Page 78
Getting Started with MAXserver Access Servers
Pin Assignments Ethernet Transceiver Cable Figure 25 shows the standard 15-pin AUI connector signal assignments.
8
1
15
9
Pin
Signal
1 2 3 4 5 6 7 8 9 10 11 12 13 14 15
Chassis Ground Collision + Transmit + Chassis Ground Receive + Power Return Not Used Not Used Collision Transmit Chassis Ground Receive Power (+12Vdc) Chassis Ground Not Used
Figure 25 - Ethernet 15-Pin AUI Connector Assignments
10Base-T Connector Figure 12 shows the standard 10Base-T (RJ-45 jack) connector signal assignments.
78
0038
Page 79
Getting Started with MAXserver Access Servers
12345678
Pin
Signal
1 2 3 6
TD+ TDRD+ RD-
Figure 26 - 10Base-T Connector Assignments
RJ-45 and DB-25 Pins Figure 27 shows RJ-45 and DB-25 pin assignments. 1
14
13
25
12345678
87654321
RJ-45 Jack (Female)
13
RJ-45 Plug (Male)
25
DB-25 (Female)
1
DB-25 (Male)
Figure 27 - RJ-45, DB-25 Pins
0038
14
79
Page 80
Getting Started with MAXserver Access Servers
Using the Configuration Menu This section explains each parameter in an intialization record and how to change the configuration parameters for the access server using the Configuration Menu, or you can enter the appropriate command at the Xyplex prompt instead of using the menus. Most of the time, the default values in initialization records load software automatically, so often you do not have to change them. Each access server provides Initialization Configuration software that you use to:
·
View current settings of initialization parameters and change the settings when necessary.
·
Change the protocol used to load parameters.
·
Change the protocol used to receive a software load image, or change the name of the load image that it requests.
·
Change the protocol used to transmit dump files.
·
Instruct the operating software, once loaded, to initialize server and port parameters.
·
Configure multiple initialization (load/dump) configurations.
·
Change the unit’s memory settings whenever you add or remove memory (SIMMs).
80
·
Reset the parameter initialization records to default factory settings.
·
Rename the software image load file.
0038