Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 6 of 17

Getting Started With MAXserver Access Servers, Models 1604, 1608A/B, 1620 and 1640, pages 51 to 60

Pages 51 to 60 of 164

The original document is the PDF (902 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Xyplex MX-1620

Page 51

Getting Started with MAXserver Access Servers

Flash Cards This section describes how to use flash cards. Flash cards are readable/writeable and can be updated to a newer software version. See the Software Installation Guide for Xyplex Loaders for instructions. The commands used to update flash cards are located in the Commands Reference Guide. You can perform the following tasks with the image file contained on the flash card:

·

Copy the file to another card

·

Delete the files

·

Display the current status

·

Format the card

·

Load the image file

·

Terminate file updates

Loading the Image File The DEFINE SERVER LOAD SOFTWARE command specifies the CARD/XMOP/MOP filename that contains the software load image. You specify this filename if CARD, XMOP, or MOP is enabled as a load protocol for the software load image, and the load image name is different from the default. The default software load image name for a MAXserver is XPCSRV20. The CARD/XMOP/MOP load image filename appears in the Server Loaddump Characteristics display shown in Figure 27.

0038

51

Page 52

Getting Started with MAXserver Access Servers

Use the following command to load the image file: DEFINE SERVER LOAD [PRIMARY] SOFTWARE “FILENAME” [SECONDARY] [TERTIARY] Example This example specifies XPCSRV20 as the filename for the secondary initialization record. XYPLEX>> DEFINE SERVER LOAD SECONDARY SOFTWARE XPCSRV20

Changing the Software Image Filename The software load image filename appears in the Software field on the Loaddump characteristics display (see Figure 33). The default filename for all MAXservers is XPCSRV20. The filenames apply to primary, secondary, and tertiary initialization records. Use the following command to specify a name for the software load image file: DEFINE SERVER LOAD [RECORD |ALL] SOFTWARE FILENAME record

The primary, secondary, or tertiary initialization record.

filename

The software load image filename.

Example This example specifies the software load image filename for the primary initialization record: XYPLEX>> DEFINE SERVER LOAD PRIMARY SOFTWARE XPCSRV20

52

0038

Page 53

Getting Started with MAXserver Access Servers

Copying Flash Cards Use this command on units that have flash cards. You can copy the entire contents of one card to another with this command. XYPLES>> SET SERVER CARDCOPY

Deleting Flash Cards Use this command on units that have flash cards. You can delete the entire contents of a flash card. XYPLEX>> SET SERVER CARDCOPY ERASE

CAUTION DO NOT USE THIS COMMAND UNLESS YOU ARE ABSOLUTLEY SURE THAT YOU WANT ALL CONTENTS DELETED.

Displaying the Flash Card Settings Use this command to display the card’s current settings. XYPLEX>> SHOW CARD STATUS

0038

53

Page 54

Getting Started with MAXserver Access Servers

Xyplex > show card status TS/720 V6.1 Rom 4C0000 HW 00.02.00 Lat Protocol V5.2 Uptime 0 10:25:35 Address:08-00-87-02-58-64 Name:X025864 Ethernet:A Number:

0 04

Dec 1998

12:44:11

Card Status: Card Type: Device Type: Card State:

Formatted / Write Enabled Xyplex / FLASH2 / 2097152 bytes Intel / 65536 bytes Idle

Get File Host: Get File Name: Get File Area: Get File Current State: Get File Previous Status:

Idle None

Parameter Area Updates:

25

Xyplex>

Field

Description

Card Status:

Formatted and write enabled.

Card Type:

Manufacturer - can be anyof the following:

-

Fujitsu

-

Micron

-

Mitsubishi NEC

-

NBase-Xyplex

-

Samsung

-

Toshiba

Flash = SERIES 1, Flash2 = SERIES 2 Size of Flash card

54

Card State:

Idle

Device Type:

Manufacturing and size of ROM chips on the Flash card.

Get File Host:

Where you get file from.

0038

Page 55

Getting Started with MAXserver Access Servers

Get File Name:

Name of file.

Get File Area:

Area of flash card to put file.

Get File Current State:

What the card is currently doing.

Get File Previous State:

Did previous GET FILE succeed.

Parameter Area Updates:

How many times the PARAM Area of the Flash card was updated since the server was rebooted.

Updating Images You must re-initialize the unit after updating the card, if you want to use the new software version immediately. Use the following command to initiate and terminate flash card load image updates. SET SERVER GET CARD [LOADFILE] [“FILE-NAME”] IP ADDRESS [IP-ADDRESS] AREA [AREA-NUMBER] ETHERNET ADDRESS [ETHER-ADDRESS] AREA [AREA-NUMBER] [STOP]

Where

Means

LOADFILE

Loads the image file.

"file-name”

The image’s file name. Enclose the name in quotes.

0038

IP ADDRESS

Location of stored file to GET.

STOP

Terminates the file loading process.

ETHERNET ADDRESS

Location of the stored file to GET 55

Page 56

Getting Started with MAXserver Access Servers

AREA

The area on the card where the image file is located.

Depending on the file’s location, include either the IP address or Ethernet address where the file is located. NOTE: There is no Define command for this option. Examples SET SERVER GET CARD LOADFILE “xpcsrv20.sys” IP ADDRESS 140.179.192.110 SET SERVER GET CARD STOP

56

0038

Page 57

Getting Started with MAXserver Access Servers

Rebooting Use the INITIALIZE SERVER command to reboot the access server, or to cancel a previous INITIALIZE SERVER command. Using the INITIALIZE command, the access server returns to a state which is exactly the same as if you powered up the server (i.e., all settings are restored to the values specified in the permanent database. Values specified using SET commands are reset to the values in the permanent database, users are logged out, and the server image is reloaded).

INITIALIZE DELAY Command You can specify a delay period before the access server reboots. When you issue the INITIALIZE command without specifying a delay period, the access server broadcasts a warning to all ports notifying any users who are logged on (the default is 1 minute). If you specify a delay time which is between 2 and 29 minutes, the server will broadcast a warning immediately, and then every minute for each of the last 5 minutes, until re-initialization. If you specify a delay of 30 minutes or greater, the access server will broadcast a message immediately, once every 30 minutes prior to reinitialization, and then once every minute for the last 5 minutes. These messages are broadcast regardless of the BROADCAST setting. Broadcast messages are only displayed at ports that have BROADCAST enabled.

0038

57

Page 58

Getting Started with MAXserver Access Servers

If you specify INITIALIZE DELAY 0,the server will reboot immediately unless there are unsaved parameters, in which case you will receive the "Warning Configuration Not Saved" error message (message 198). If you specify INITIALIZE DELAY n with a delay value other than 0, and a user changes a permanent parameter (i.e., uses a Define command) before n minutes expire, the initialization is delayed until the parameters are saved. If the parameter server cannot save the parameters, the user who entered the Define command will receive the 198 error message, and the server will not reboot. Use the following command to reboot the server: INITIALIZE SERVER DELAY [delay-time] [OVERRIDE] or INITIALIZE DELAY [delay-time]

Where

Means

SERVER

An optional keyword.

DELAY

Re-initialization to occur after a specified period of time.

delay-time

How long the server will wait until the re-initialization occurs. Valid values are 0 to 32767 minutes. The default value is 1 minute.

OVERRIDE

The server will perform the initialization even if there are unsaved parameters. If you do specify "OVERRIDE" and parameters have only been partially updated, the parameter file can become corrupted.

CANCEL

58

Cancel a previously issued INITIALIZE command.

0038

Page 59

Getting Started with MAXserver Access Servers

Examples INITIALIZE DELAY 1 NITIALIZE SERVER DELAY 5 INITIALIZE SERVER DELAY 5 OVERRIDE INITIALIZE CANCEL

0038

59

Page 60

Getting Started with MAXserver Access Servers

Cabling Considerations NBase-Xyplex offers a family of products that support access serving features. Each product can be connected to a variety of modems or other devices through one of three wiring schemes (with 6, 7, or 8 wires) which support different modem control and hardware flow control options. A fourth wiring scheme, which is available on some products, uses 3 wires and is not suitable for modem-based applications. Standard cabling items available from NBase-Xyplex allow you to connect to any serial device that uses a male or female DB-25 connector. All you need is the appropriate modular cable (crossover cable for connecting to a DTE device, straight-through cable for connecting to a DCE device), and the correct modular adapter (male or female DB-25 connector), which is essentially an RJ-45-to-DB25 adapter.

Ordering Cables NBase-Xyplex also supplies DEConnect-compatible crossover cables and modular adapters for use with all MAXserver units. To order cables, adapters or other cabling accessories from NBase-Xyplex, contact your Sales representative or distributor.

Cabling Types Table 3 lists the cabling types and modem/flow control supported for each. Table 3 - Cabling Types and Flow Control Cabling Type 6-wire

Modem Control

Hardware Flow Control

Products

X

NO

MX-TSERV-J8, MX-TSRVM-J8, and MX2120 Access Server cards.

60

0038