The text of a manual · part 3 of 17

Getting Started With MAXserver Access Servers, Models 1604, 1608A/B, 1620 and 1640, pages 21 to 30

Pages 21 to 30 of 164

The original document is the PDF (902 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Xyplex MX-1620

Page 21

Getting Started with MAXserver Access Servers

7. Connect the power cord to rear of the unit, then to an AC power outlet, and observe the front panel lights. 8. Connect the serial device cables to the unit and to the devices (terminals, PCs, etc.), and initialize the devices. The following sections provide more detailed installation instructions.

Unpack and Inspect the Unit Follow these steps: 1. Carefully unpack the unit shipping carton. 2. Inspect the contents and make sure that you received all parts listed on the shipping order. 3. Place all packing materials back into the shipping carton and save the carton. (If you need to return the unit to NBase-Xyplex or your distributor, you should return it in the original carton.) 4. If the unit has been damaged in shipping or any parts are missing, notify your NBase-Xyplex representative or distributor immediately.

Place the Unit on a Flat Surface or Mount on Rack Select a location for the unit that meets the following requirements: Adequate Space -- A standard 19" rack or a 19" x 15" flat, stable surface such as a shelf or desktop must be available or use the instructions in Section 2.3.1 to mount it in a standard 19" rack. You can locate the unit in a variety of environments, including an office or computer room, provided the environmental requirements are met.

0038

21

Page 22

Getting Started with MAXserver Access Servers

To reduce the possibility of dust entering the unit and to allow easy inspection of the unit's front panel lights, make sure that the MAXserver is located at an optimum distance (preferably not less than 18 inches/45 centimeters) from the floor. Environment -- Do not choose a location where the unit will be exposed to direct sunlight or subjected to vibration. Also, the unit must be installed in an environment with 20% to 80% humidity, noncondensing, 0° - 40° C (32°113° F).

+

Do not remove the MAXserver unit's "feet." Do not place an object on the side(s) of the unit that might block airflow through the unit.

Rack Mount Installation (optional) Rack mount installation is easier when performed by two persons -- one person holding the unit while another secures the mounting bolts with a Phillips-head screwdriver. (Threaded clips and bolts are supplied with the unit). Complete these steps: 1. Locate a mounting position on the rack that allows at least one inch of space above and below the unit. 2. Secure the unit to the mounting rack using the supplied bolts, as shown in Figure 3. If the rack is not threaded, use the threaded clips supplied with the server.

22

0038

Page 23

Getting Started with MAXserver Access Servers

Rack

Threaded clips -- optional; use if the rack is not threaded

Figure 3 - Mounting a MAXserver in Rack

Insert the Flash Card (if Supplied) If the unit is supplied with a Flash Card, insert the card into the card slot on the front panel.

+

NBase-Xyplex recommends that you wear a grounded wrist strap when you insert the flash card. If none is available, ground yourself by placing one hand on the unit (or another grounded object), before you insert the flash card, to prevent static from being discharged into the unit.

Markings on the flash card indicate which end you insert into the unit. (As another indication, the end you insert has two rows of small square holes.)

0038

23

Page 24

Getting Started with MAXserver Access Servers

Connecting the Ethernet Interface Connect either a 10Base-T or AUI Ethernet network cable to the appropriate connector on the rear of the MAXserver (See Figure 4 for 20-port and 40-port models; Figure 5 for 8-port and 4-port models.) Connect only one Ethernet cable to the unit. When powered up, the unit selects the interface on which it detects network activity.

MAXserver 1620 Terminal Server 110 - 240 VAC ~ 1.0 - 0,5A 50 - 60 Hz

1

2

3

4

5

6

7

8

9

10

11

12

13

14 15 16

RJ-45 Serial Port Connectors.

17

ETHERNET

18 19 20

10BASE-T Ethernet RJ-45 Connector

Standard Ethernet (AUI) Connector Link LED

MAXserver 1640 Terminal Server 110 - 240 VAC ~ 1.0 - 0,5A 50 - 60 Hz

ETHERNET

RJ-45 Serial Port Connectors. Top Row: Ports 1 through 20 Bottom Row: Ports 21 through 40.

10BASE-T Ethernet RJ-45 Connector

Standard Ethernet (AUI) Connector Link LED

Figure 4 - MAXserver 1620/1640, Rear View

24

0038

Page 25

Getting Started with MAXserver Access Servers

Figure 5 - MAXserver 1604/1608B, Rear View Standard (AUI) Connection -- Plug the male cable connector into the 15pin female AUI socket on the rear of the unit and fasten the slide latch. (The AUI connector signal assignments are shown in Figure 25.) 10Base-T Connection -- Install the Ethernet cable by plugging it into the 10Base-T connector on the rear of the unit. (The 10Base-T connector signal assignments are shown in Figure 26.) If you use the 10Base-T connector, the LINK LED will light when the unit detects that it is connected to a working Ethernet network.

0038

25

Page 26

Getting Started with MAXserver Access Servers

Connect the Power Cable You do not need to set the unit for 115V or 230V operation. The power supply automatically adapts to the input voltage. A grounded AC power outlet should be located within six feet of the back of the unit. You can use a UL-approved, 3-prong extension cord if necessary, provided it has sufficient current and voltage capacity. (The cord must have sufficient capacity for the input power, and AC power must meet the criteria listed in). To connect the power cable, complete these steps: 1. Plug the AC line cord (supplied) into the AC power receptacle on the rear of the unit. (See Figure 4 for the location of the power receptacle.) 2. Plug the other end of the cord into a grounded 3-prong AC power outlet (or a UL-approved extension cord with sufficient capacity that is plugged into a suitable outlet). 3. When you apply power, the unit performs a self test of its circuitry and then proceeds to load its software. When the unit has finished loading its software, the RUN light flashes slowly and the LAN light flashes as Ethernet packets are received. (Figure 6 shows the locations of the lights on the front panel.)

26

0038

Page 27

Getting Started with MAXserver Access Servers

Front Panel LEDs - MAXserver 1620/1640 The front panels of the MAXserver 1640 and 1620 access servers are identical, except for the model designation. If, after several minutes, the front panel lights do not behave as indicated, refer to the Troubleshooting section of this guide for instructions.

XYPLEX MAXSERVER 1620 CARD

Memory Card slot

Eject Button

RUN LAN CONSOLE

1 2 3 4 5 6 7 8 9 10

TERMINAL SERVER

-- These lights indicate port activity. Ports 1 - 10 Flashing = activity on associated ports. ON = port connection established. OFF = no port connection established. -- Press once to put the unit in reset state. Reset switch Press again to re-initialize the unit. CONSOLE light -- ON when someone is logged on to the unit's console port via the network. Flashes if permanent parameter changes have not yet been stored. (Do not power off the unit while this light is flashing.) LAN light -- Flashes when the unit receives Ethernet packets. Rapid blinking indicates heavy network traffic to the unit.(OFF when not connected to network, or network is faulty.) RUN light -- ON when unit is reset; flashes rapidly when unit executes firmware code; flashes slowly when software is loaded (RUN state). CARD light -- ON when Memory card is being accessed. Do not remove the card or power off the unit while this light is ON.

Figure 6 - MAXserver 1620/1640 Front Panel

Front Panel LEDs - MAXserver 1604/1608B The front panels of the MAXserver 1604 and 1608B access servers are identical, except for the model designation (see Figure 7). If, after several minutes, the front panel lights do not behave as indicated, refer to the Troubleshooting section later in this guide.

0038

27

Page 28

Getting Started with MAXserver Access Servers

Ports 1- 4 These lights indicate port activity. Memory Card Slot Flashing = Activity associated with port. ON = Port connection established. OFF = No port connection established. CONSOLE light - ON when someone is logged on to the unit’s console port via the network. Flashes if permanent parameter changes have not yet been stored LAN light - Flashes when the unit receives Ethernet packets. Rapid blinking indicates heavy network traffic to the unit. (OFF when not connected to network or network is faulty.) RUN light - ON when unit is reset. Flashes rapidly when unit executes firmware code. Flashes slowly when software is loaded (RUN state). CARD light - ON when Memory card is being accessed. Do not remove the card or power off the unit while this light is ON.

Figure 7 - MAXserver 1604 Front Panel

28

0038

Page 29

Getting Started with MAXserver Access Servers

Port Status LEDs The port status LEDs are used in several ways. During the initialization process, the LEDs indicate that self-tests are being performed, and if any self-test fails, they indicate an error code. After the unit has received a load image and parameters, the lights indicate when a port is actively being used. In this case, each light can indicate activity for more than one port. For example, if LED 1 is lit, this can indicate that there is activity on ports 1, 11, 21, or 31. LED 2 indicates activity on ports 2, 12, 22, etc.

Connect Serial Device Cables Connect the serial device cables to the 8-pin RJ-45 jacks on the rear of the unit. The signal assignments of the 8-pin jacks are shown in Figure 8. Pin

Signal

1 2 3 4 5 6 7 8

RNG/CTS (input) DTR (output) XMT (output) XMTGND RCVGND RCV (input) DSR/DCD (input) (discussed in Section B.2.2) RTS (output)

12345678

Figure 8 - Serial Device Connector (RJ-45) Signal Assignments NOTE:

0038

MAXserver serial ports provide concurrent support for RTS/CTS flow control and modem control. See the Basic Configuration Guide for information about setting up flow and modem control.

29

Page 30

Getting Started with MAXserver Access Servers

NBase-Xyplex recommends that you label all cables with the name of the device to which it connects and the number of the port you have assigned to it. This way, if the cable is removed for any reason, you can reconnect it easily. If the device cables have not yet been prepared with the correct RJ-45 connectors, see the Cabling Considerations later in this guide.

Additional Considerations for an Internet Environment If you plan to use the unit in an Internet environment, you must define addressing and identification characteristics to enable Internet hosts to recognize the unit as a member of the network. See the IP Addresses section later in this guide for information about configuring the unit for an Internet environment.

Factory Defaults Settings Each MAXserver unit is configured at the factory to use a default set of initialization parameters that sets all ports to operate with asynchronous ASCII terminal devices in order to obtain a software image. For most configurations, the default settings can load without any configuration changes. If you are not connecting keyboard terminals or PCs running VT100 terminal emulation software, proceed to “Logging in to the MAXserver.” The unit is also configured at the factory to store parameters locally in Nonvolatile storage (NVS) or on a flash card, if one is installed, and remotely at any properly configured parameter server. The following table lists the factory default settings. NOTE:

30

The default settings listed in this table are for Initialization Record 1 only. Initialization Records 2 and 3 are not enabled at the factory. However, if you enable Records 2 and 3, their default settings are the same as Record 1.