Page 31

Getting Started with MAXserver Access Servers

Table 1 - Factory Default Settings Configuration

Factory Default Setting

Initialization Record 1

Enabled

Initialization Record 2

Disabled

Initialization Record 3

Disabled

Parameter file load method

NVS, XMOP, MOP, BOOTP, RARP

Software Image load method*

CARD, XMOP, MOP, BOOTP, RARP, DTFTP*

Dump File Method

XMOP, MOP, BOOTP, RARP

Software filename for CARD/XMOP/MOP loading

XPCSRV20

Default unit IP address:

0.0.0.0

Installed memory

4 MB

Loading Status messages

Enabled

Directed TFTP values

0.0.0.0 or N/A

Server login password (#)

ACCESS

Privileged password

SYSTEM

* DTFTP is not enabled at the factory.

Autobauding Feature MAXserver serial ports are configured to adjust automatically to the communication speed of a connected terminal.

0038

31

Page 32

Getting Started with MAXserver Access Servers

NOTE:

Access servers do not autobaud when the port receives 7-bit characters with EVEN parity from the device until software loading has completed. You must use 8-bit characters with parity set to NONE in order to receive load messages and to enter into the ROM Configuration Menu.

You can only enable AUTOBAUD at a port set to local access and when the attached device is configured with the following settings: CHARACTER SIZE

8, (7 if EVEN parity)

PARITY

NONE (EVEN if character size is set to 7)

SPEED

Valid speeds between 50 and 38400. The supported port speeds are: 50, 75, 110, 134, 150, 300, 600, 1200, 1800, 2000, 2400, 4800, 9600, 14400, 19200, 21600, 26400, 28800, 33600, and 38400 bits per second (baud). The device connected to the port must be set to one of these speeds. (Ports cannot autobaud at port speeds above 38400 bps.

To autobaud the serial port, when your terminal is powered on, keep pressing RETURN until the unit recognizes the terminal. When you do this, the serial port adjusts to the communication speed of the terminal. (This process is called autobauding.)

32

0038

Page 33

Getting Started with MAXserver Access Servers

Reinitializing/Powering Off the Unit The MAXserver always stores permanent parameters (i.e., those parameters that you change using the DEFINE or PURGE command) in local storage. Some of the DEFINE SERVER Commands require that you reboot the server for the changes to take effect. A complete listing of these server commands are located in the Define Server section of Commands Reference Guide. Always reboot the server using the INITIALIZE DELAY command to prevent corruption of the parameter storage. Commands that require reinitialization display the following message when you press the RETURN key: XYPLEX - 705 - CHANGE LEAVES APPROXIMATELY XXXXXXX BYTES FREE

These commands cannot be modified by a SET command, because the server must redistribute memory resources for the feature during the boot-up process. Before you reinitialize, cycle power, or power off the unit, make sure that the parameter storage process has completed or the permanent parameters may be corrupted. To reinitialize the unit, use the privileged command: XYPLEX>> INITIALIZE DELAY 0 Issuing this command ensures that parameters have been stored before the unit reinitializes.

Resetting the MAXserver Before you power off the unit, use the following command to ensure that the unit has completed storing parameters: MONITOR PARAMETER SERVER

0038

33

Page 34

Getting Started with MAXserver Access Servers

The following screen displays: Xyplex>> MONITOR PARAMETER SERVER MX1620 V6.0.4S18 Rom 470000 HW 00.00.00 Lat Protocol V5.2 Uptime: 13 18:11:56 Address: 88-00-87-23-33-6B Name: X03346B Number: 0 21 Dec 1998 10:24:45 Check Timer: 30 Parameter Server Limit: 4 Retransmit Timer: 5 Parameter Servers: 4 Retransmit Limit: 3 Rejected Servers: 39 Bad Parameter Messages: 0 Path: Last Update Version: Last Update Date: Last Update Time: Name Local MemCard Local NVS

102C5 07 Dec 1998 16:12:53

Address 88-00-87-23-33-6B 88-00-87-23-33-6B

Storage State: Loaded From:

Idle 08-00-87-03-34-6B X03346B

Version Date Status 102C5 07 Dec 1998 16:12 Current 102C5 07 Dec 1998 16:12 Current

Reason

Figure 9 - Monitor Parameter Server Display The storage process is completed when the “Status” column on this display says “Current” for all parameter servers, and the “Storage State” field says “Idle.” When these conditions are met, you can turn the unit off.You can reset the MAXserver to force it to run a self test or to re-initialize the unit. Before resetting the server, check the port lights to make sure that no connections are in progress. All connections are terminated when the server is reset. To reset the MAXserver, follow these steps: 1. Make a simple "tool" from an ordinary paper clip by bending one end outward. You need this tool to press the RESET button located behind the MAXserver front panel. 2. Look for the small hole between the CONSOLE light and the light labeled '1’ (see Figure 10).

34

0038

Page 35

Getting Started with MAXserver Access Servers

X

XYPLEX MAXSERVER 1600 CARD

RUN LAN CONSOLE 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 16

TERMINAL SERVER

Reset switch -- Press once to put the unit in reset state. Press again to re-initialize the unit.

Figure 10 - RESET Switch Location 3. Use the paper clip tool to press the RESET button once. This halts all MAXserver operations -- the server will no longer send or receive network data or data from its connected devices. When the MAXserver enters RESET state, all front panel lights illuminate. 4. Press the RESET button again. The MAXserver begins its self test.

·

If the MAXserver detects an error, the front panel lights illuminate as described in the Troubleshooting section of this guide. This error sequence continually repeats until the error is corrected or you power off the MAXserver. During this time, no data is exchanged over the Ethernet cable or server ports.

·

If the MAXserver does not detect an error, it will begin loading software from the flash card or begin requesting a network load (if no flash card is present). Once loaded, the MAXserver resumes normal operations.

If your MAXserver does not behave in this manner, see the Troubleshooting section for advice.

0038

35

Page 36

Getting Started with MAXserver Access Servers

Connecting Other Devices If you are connecting a modem, printer, plotter, host computer, or data switch, refer to the following documentation for instructions, as follows: Serial Printers, Plotters -- See the Printer Configuration Guide. Modems, Data Switches – See the Basic Configuration Guide. Host Ports – See the Basic Configuration Guide.

36

0038

Page 37

Getting Started with MAXserver Access Servers

Logging in to the Access Server When your terminal is properly connected to the unit, turn its power ON, then press <RETURN> (or ENTER) a few times -- until the unit recognizes the terminal. When the unit responds, you see the following message on your screen: WELCOME TO THE XYPLEX ACCESS SERVER. ENTER USERNAME> Type your name, your initials, or a nickname, then press <RETURN>. You can type up to 16 characters (numbers or letters). This name is your identifier during this session. If you choose, you can change this information each time you make a connection. It will be shown whenever you or any other person on the network requests information about who is connected to the unit. After you enter your username, the unit returns the local command prompt: XYPLEX> To allow the system administrator to modify server and port settings, you must be in privileged mode. To enter privileged mode, use the following command: XYPLEX> SET PRIVILEGED The password prompt displays. Enter the default password “SYSTEM”. The password is not case-sensitive. PASSWORD> SYSTEM Now the following prompt displays, which indicates you are now in

0038

37

Page 38

Getting Started with MAXserver Access Servers privileged mode. XYPLEX>> See the Commands Reference Guide for the commands that require the user to be in Privileged mode. The unit is now ready to accept any of the commands described in the Commands Reference Guide. You can obtain onscreen information about the access server commands by typing HELP and pressing <RETURN>: XYPLEX>HELP

38

0038

Page 39

Getting Started with MAXserver Access Servers

Telneting into the Access Server Console Port Do the following to telnet into the console port on an access server: NOTE: You should issue both the DEFINE and SET commands where they are indicated in the following procedure. Issuing both the DEFINE and SET commands ensures that the parameter change will take effect without rebooting the unit. 1. Configure the essential IP characteristics on the Access Server as follows: a. Configure the IP Address to be assigned to the access server: define server ip address [ip-address] set server ip address [ip-address] b. Disable the Subnet Mask Autoconfigure feature. This disables the access server’s ability to automatically define the natural subnet mask based on the IP address assigned to the unit. For example, the default subnet mask for a Class B network is 255.255.00. The default setting for Subnet Mask Auto-configure is ENABLED. You must disable the autoconfigure feature in order for the server to save any other variable-length subnet mask. Use the following commands to disable the Subnet Mask Autoconfigure feature: define server ip subnet mask autoconfigure disabled set server ip subnet mask autoconfigure disabled

0038

39

Page 40

Getting Started with MAXserver Access Servers c.

Configure the Subnet Mask for the access server. The subnet mask must be consistent with the network on which the access server will reside. Use the following commands: define server ip subnet mask [ip-address] set server ip subnet mask [ip-address] d.

Configure the default first-hop Router/Gateway: define server ip primary gateway address [ip-address] set server ip primary gateway address [ip-address]

2. Specify Telnet Port 2000 when connecting remotely: Be sure to specify telnet remote port# 2000 when trying to connect. If no port/socket number is specified, then most Telnet applications will use port 23 by default. Unless the Xyplex's console port has also been redefined to port 23, then any attempts to Telnet into the server's console port will be refused. The current port setting on the access server is displayed in the “Remote Port” field of the “show port 0 telnet characteristics” screen. Figure 11 shows a “show port 0 telnet characteristics” screen with the “Remote Port” field set at 2000. MX1620>> show port 0 telnet characteristics Port 0:

admin

Abort Output Character: None Attention Character: None Default Port: 23 Echo Mode: Character Erase Keystroke Character: None Erase Line Character: None Interrupt Character: None TerminalType: None Tn3270 TranslationTable: None Local Port: 4000

05 Jan 2000

19:33:48

Newline: CR/NULL Newline Filtering: None Query Character: None Remote Port: 2000 Synchronize Character: None Transmit: BuffTime 80 Binary Session Mode: PASTHRU Tn3270 Device: None Tn3270 Printer Port: Any Tn3270 Default Port: 23

Enabled Characteristics:

Figure 11 - Sample SHOW PORT 0 TELNET CHARACTERISTICS Display

40

0038