Page 11
Figure 33 - Sample Primary Initialization Record Display ................................... 108 Figure 34 - Primary Initialization Record Display................................................. 118 Figure 35 - Sample Error Code Display .................................................................. 130 Figure 36 - Typical SIMM ........................................................................................ 144 Figure 37 - Removing the Screws Securing the Cover.......................................... 145 Figure 38 - Location of SIMM Sockets .................................................................... 146 Figure 39 - Inserting SIMM into Socket ................................................................. 148 Figure 40 - MAXserver Access server Configuration Menu .................................. 151 Figure 41 - Sample Display Unit Configuration Display....................................... 151 Figure 42 - Sample Miscellaneous Configuration Display..................................... 152 Figure 43 - Removing SIMMs.................................................................................. 154
0038 xi
Page 12
Page 13
Getting Started with MAXserver Access Servers
About the MAXserver The MAXservers are standalone access servers that provide: Serial Ports – The MAXserver is available in the following configurations:
·
The MAXserver 1620 provides 20 asynchronous serial communication ports with RJ-45 interfaces.
·
The MAXserver 1640 provides 40 asynchronous serial communication ports with RJ-45 interfaces. (See Figure 4 for connector signal assignments.)
·
The MAXserver 1608 provides 8 asynchronous serial communication ports with RJ-45 interfaces.
·
The MAXserver 1604 provides 4 asynchronous serial communication ports with RJ-45 interfaces.
Figure 4 and Figure 5 show rear and front views of the MAXserver 1620 and MAXserver 1640. Figure 6 and Figure 8 show rear and front views of the MAXserver 1608A and MAXserver 1604. NOTE:
The front and rear panels of the MAXserver 1608A are identical to the MAXserver 1620 and 1640 except for the number of ports available.
Ethernet Interfaces -- A 15-pin standard Ethernet Interface Attachment Unit Interface (AUI) connector and a 10Base-T Ethernet interface (RJ-45 connector). (See Figure 15 for AUI connector signal assignments.) TCP/IP and LAT Protocol Support -- The MAXserver provides concurrent support for the DEC Local Area Transport (LAT®) and TCP/IP protocols.
0038
13
Page 14
Getting Started with MAXserver Access Servers
Flash Card -- An optional card, from which the unit can load its operating software. The MAXserver can also load software from the flash card to other NBaseXyplex access server units on the network for which it has a load image. Network Software Loading -- If you order a MAXserver without a flash card, the unit loads its operating software from a network host called a load server. The load server is typically a UNIXÔ or VAX/VMSÔ system. However, you can also use a MAXserver Manager card (MAXman) or another MAXserver. The load server downloads a software image to the MAXserver over the network whenever the access server is powered on or re-initialized. The load serverm can support other devices as well. Expandable Memory – All MAXserver units are shipped with 4 MB of factory installed memory. The memory can be expanded in 2 MB increments, up to 8 MB, using SIMM memory modules. SIMMs should be installed by qualified personnel only. To upgrade your MAXserver, contact your NBase-Xyplex sales representative or distributor. Installation instructions are provided later in this Guide. Concurrent Flow Control and Modem Control Support -- The MAXserver provides concurrent support for RTS/CTS flow control signals and modem control; signals on all ports. Adapters are available to support cabling to MAXserver ports when these signals are used. In most cases, the MAXserver can also use standard MAXserver 1000-series cabling, if support for the new signals is not required.
14
0038
Page 15
Getting Started with MAXserver Access Servers
Supported Communication Speeds MAXserver
Communication Speed
MAXserver 1604
50 - 115.2 Kbps
MAXserver 1608A/B
50 - 115.2 Kbps
MAXserver 1620
50 - 115.2 Kbps
MAXserver 1640
50 bps to 57.6 Kbps
Software Requirements MAXserver 1608A, 1620, 1640
Release 5.3 or higher
1604 and 1608B
Release 6.0.3 or higher
NOTE:
0038
Minimum Software Requirements
If you are unsure of the software version you are running, enter the SHOW UNIT command at the Xyplex prompt to display the unit’s current software version.
15
Page 16
Getting Started with MAXserver Access Servers
Hardware Type: Hardware Revision: Rom Revision: Software Type: Software Revision: Protocol Type: XPRINTER
86 00.00.00 470000 Access Server Level 4 V6.1 LAT, TELNET, RLOGIN, TN3270, ARAP, SNMP, PPP, IPX,
Daemon(s):
LPD
Enabled Feature(s): APD, HELP, INTERNET SECURITY, IP FILTERING, IPX FILTERING, ULI, SECURID, MENU, NESTED MENUS, KERBEROS, RADIUS APD Message: AutoProtocolDetect - Begin protocol or enter 4 returns for interactive mode.
Figure 1 - Sample SHOW UNIT Display
Downloading Software MAXservers are configured at the factory to load software from a flash card, if one is inserted in the card slot. If a card is not present, the unit requests software from a network load server, which can be:
·
A MAXserver that is equipped with a flash card
·
A MAXserver Manager (MAXMAN) card or Network 9000 processor module
·
A VAX/VMS host system, from which the unit can load via DEC Maintenance Operations Protocol (MOP)
·
A UNIX system running: - Bootstrap protocol (BOOTP) and Trivial File Transfer Protocol (TFTP), or - Reverse Address Resolution Protocol (RARP) and TFTP
16
0038
Page 17
Getting Started with MAXserver Access Servers
The load server downloads a software image to the MAXserver, over the network, whenever the unit is powered on or re-initialized. By default, the unit requests software from each type of load server, until a server responds with a software load offer. If you need to install software on a network load server, refer to the Software Installation Guide for the type of load server you plan to use.
Configuration Options There are two Graphical User Interface configuration utilities that you can use instead of using the Access Server Configuration Menu or the Command Line interface to configure the MAXserver. These utilities simplify the task of configuring MAXservers - FocalPoint and ControlPoint. About FocalPoint FocalPoint for Access Servers is a Windows-based configuration utility with a point-and-click graphical interface (GUI) designed to step you through the process of configuring MAXservers. FocalPoint guides you through the logical progression of setup choices complete with default settings and context-sensitive online help.Using FocalPoint to configure the MAXserver eliminates the need to learn a complex command line interface. FocalPoint automatically ships free of charge on the software and documentation CD with all Network 3000, Route Runners, MAXserver, and 720 Series Access Server modules for the Network 9000. The latest versions of FocalPoint software are also available from the NBase-Xyplex Web Site.
0038
17
Page 18
Getting Started with MAXserver Access Servers
To use FocalPoint, simply load the software from the CD that was shipped with the MAXserver. From FocalPoint, you can select your MAXserver model and also provide all pertinent information before you can advance to the next step. FocalPoint will not prompt you for options not available to your system.
Figure 2 - Sample FocalPoint Configuration About ControlPoint The ControlPoint network management application is standards-based, portable and runs on inductry-leading network management platforms such as Microsoft Windows 95 and NT, Sun Microsystems (SunNet Manager) and Hewlett Packard (HP OpenView).
18
0038
Page 19
Getting Started with MAXserver Access Servers
ControlPoint is tailored for NBase-Xyplex devices. It provides easy configuration through a simple point-and-click Graphical User Interface (GUI). ControlPoint’s Policy Manager reduces the risk of error, simplifies repetitive tasks, and saves network administrators time. A trend analysis application provides monitoring and graphing of long-term internetworking trends. To order ControlPoint, contact your NBase-Xyplex Sales Representative.
Related Publications The following publications are useful to persons who install and manage NBase-Xyplex access servers. The following publications were included on the CD with your access server software. To obtain hard copies, contact your NBase-Xyplex sales representative or distributor. MAXserver Documentation Document Title
Document Number
Basic Configuration Guide
451-0084
Advanced Configuration Guide
420-0558
Printer Configuration Guide
451-0112
Commands Reference Guide
420-0559
Error Messages Reference Guide
451-0049
Using the Xyplex ULI
451-0062
Using the Xyplex APGEN Utility
451-0065
Software Installation Guides
0038
UNIX
420-0390
VAX/VMS
420-0391
Xyplex Loader
420-0392
19
Page 20
Getting Started with MAXserver Access Servers
Installation This section explains how to install a MAXserver and place it into operation. The basic installation consists of the following procedures: 1. Unpack the unit, check the contents against the packing list, and inspect for possible damage during shipping. 2. Mount the unit in a standard 19" rack or place it on a suitable flat surface (19" x 15"). 3. If the unit is equipped with a flash card, insert the into the card slot on the front of the unit. NOTE:
NBase-Xyplex recommends that you wear a grounded wrist strap when you insert the card. If none is available, ground yourself by placing one hand on the unit (or another grounded object), before you insert the flash card, to prevent static from being discharged into the unit.
4. If the unit is not equipped with a flash card, verify that Release 5.3 or greater of Access Server software is installed in the network (Release 6.0.3 or higher if using the MAXserver 1604 or 1608B). 5. If you are installing a unit that is equipped with a flash card, as well as units that are not, install the unit with the flash card first. That unit can then serve as a load server for the other units. 6. Connect the Ethernet transceiver cable or 10Base-T network cable to the unit.