Page 141
Getting Started with MAXserver Access Servers
If the LAN Light Is Out Correct Operation: When the LAN light on the MAXserver front panel is ON, the server is communicating with the network. Solution: If you are unable to communicate with the network and the LAN light is not ON, check the following.
·
Make sure that the Ethernet transceiver cable or 10BASE-T network cable is securely connected to the back of the MAXserver.
·
There may be a problem with the network itself. Check whether any other devices connected to the network are experiencing communications problems.
·
Check whether a diagnostic code is being displayed on the front panel lights (indicating a hardware or software error).
If none of these checks indicate a problem and the LAN light is still not ON, contact your NBase-Xyplex Customer Support representative for assistance. (In the U.S., call NBase-Xyplex Customer Support at 1-800-435-7997. For International calls, the number is 987-952-4888).
0038
141
Page 142
Getting Started with MAXserver Access Servers
SIMMs Installation This section explain how to install and remove MAXserver Single Inline Memory Modules (SIMMs). ATTENTION Only qualified personnel should install or remove MAXserver SIMMs. Unplug the MAXserver before you begin the installation. There is danger of Electrical Shock if you fail to do so. SIMMs are extremely sensitive to static electricity. Static from your clothes or work environment can destroy SIMMs, or diminish their reliability. Handle SIMMs by their edges only, and use standard staticpreventive procedures. Preferably, the installation should be done with an anti-static wrist band, on a grounded work surface.
Recommended SIMMs Manufacturers The MAXserver accepts 30-pin 70 ns. (or faster) 1M x 8 SIMMs with tin contacts. (Do not use SIMMs with gold contacts.). The order code for a 2MB SIMM memory upgrade kit is MX-500-5744. Contact your NBase-Xyplex sales representative to order this kit. Problem: Determining what type of SIMMs can be used to upgrade a 1600, 1620 or 1640.
142
0038
Page 143
Getting Started with MAXserver Access Servers
Solution: The requirements for SIMMs are as follows: For a 1620/1640:
·
30 pins, 70 ns or faster, 1M x 8 SIMMs with tin contacts (NOT GOLD). They must be configured to make either 2, 4, 6 or 8 Megabytes of memory.
·
Manufacturer's Part No.ToshibaTHM81070AS-70
For a 1600:
·
30 pins, 80 ns or faster, 1M x 8 SIMMs with tin contacts (NOT GOLD).
·
Manufacturer's Part No.
-
NEC MC-421000A8B-80OKIMSC2313A-80YS8
-
Toshiba THM81000AS-80
-
Samsung KMM581000A-8
-
Micron MT8D18M-8
-
Mitsubishi MH1M08B0J-8
-
Fujitsu MB85230A-80PS
NBase-Xyplex offers SIMM Upgrade kits for all MAXserver units. Contact your NBase-Xyplex sales representative for ordering information.
0038
143
Page 144
Getting Started with MAXserver Access Servers
MAXserver Memory Requirements Each SIMM provides 1 Megabyte of memory. SIMMs must be installed or removed in pairs; you can install either two, four, or six SIMMs (i.e., 2, 4, or 6 Megabytes of memory). This means that the MAXserver can be configured with a total of 4, 6, or 8 Megabytes of memory. Figure 36 shows a typical SIMM. (The SIMMs you are installing might have a different number of memory chips.) NOTE:
All MAXserver are delivered from the factory with a minimum of 4MB installed. Memory chips
1
30
Pin contacts
Figure 36 - Typical SIMM
Installation
+ Unplug the MAXserver before you begin the installation. There is danger of Electrical Shock if you fail to do so. To install the SIMMs, follow these steps: 1. Unplug the MAXserver if you have not already done so. It is not necessary to remove the serial cables and Ethernet cable. If the MAXserver is mounted in a rack, remove it from the rack.
144
0038
Page 145
Getting Started with MAXserver Access Servers
2. Set the MAXserver on a grounded workbench or other flat, stable surface. 3. Attach an anti-static strap to your wrist, and connect the strap to a well grounded object. If a well grounded object is not available, connect the strap to the MAXserver chassis after you remove the cover. 4. Remove the four screws that secure the cover on the MAXserver, using a Phillips-head screwdriver (see Figure 37). Put the screws in a safe place. Then, lift and remove the cover.
Figure 37 - Removing the Screws Securing the Cover
+ Do not touch the Power Supply. Components might still be charged to dangerous voltages. 5. Locate the SIMM sockets inside the MAXserver (see Figure 38).
0038
145
Page 146
Getting Started with MAXserver Access Servers
(REAR)
Power Supply Memory Card Slot
Retainers
6 5
4 3 SIMM Sockets 2 1
Figure 38 - Location of SIMM Sockets
146
0038
Page 147
Getting Started with MAXserver Access Servers
6. Install two SIMMs at a time, and install them into the sockets in the following order: 1 and 2, then 3 and 4, then 5 and 6. (It is easier to install each pair of SIMMs by installing the SIMM in the odd-numbered sockets first.) 7. Hold the SIMM by its edges, with the memory chips facing the front of the MAXserver, then insert the SIMM into the slot. Angle the top of the SIMM (about 30°) toward the rear of the MAXserver (see Figure 39). 8. Place your thumbs on opposite corners of the SIMM and press down. 9. Press forward (toward the rear of the MAXserver) until you feel the SIMM snap into place.
0038
147
Page 148
Getting Started with MAXserver Access Servers
1. Insert SIMM at 30° angle. Press down.
(Rea r of u nit)
2. Press forward, until SIMM snaps into place.
Figure 39 - Inserting SIMM into Socket
10. Make sure that the SIMMs are secure within the retainers. 11. Replace the MAXserver cover, and secure it with the four screws you had removed. 148
0038
Page 149
Getting Started with MAXserver Access Servers
12. Return the unit to the rack or flat surface from which you removed it, and plug it back in. 13. When you apply power, the MAXserver performs a self test of its circuitry and then proceeds to load its software. When the unit has finished loading its software, the RUN light flashes slowly and the LAN light flashes as Ethernet packets are received. If, after several minutes, the front panel lights do not behave as indicated, refer to the Troubleshooting section. No other actions are required. The MAXserver automatically detects, tests, and records the presence of the additional memory. However, if you want to verify that the MAXserver has detected the additional memory, proceed to the next section.
Verifying Memory Installation Using Commands You can verify that the MAXserver has detected the additional memory. To do so, follow these steps: 1. Connect a terminal to any MAXserver serial port. 2. Press <RETURN> several times to "autobaud" the serial port to the terminal's speed. 3. Enter a username when prompted. 4. Use the following command to generate a display that indicates the amount of memory the MAXserver detects. (Look for the "Installed Memory" field in the upper left portion of the display.) At the Xyplex prompt, type: SHOW SERVER ALTERNATE STATUS
Verifying Memory Installation Using the Configuration Menu You also can use the MAXserver Access server Configuration menu to verify 0038
149
Page 150
Getting Started with MAXserver Access Servers the memory installation by following these steps: 1. Using a straightened paper clip, press the MAXserver RESET switch once to enter reset mode. All lights on the front panel should illuminate. 2. Press the RESET switch again, and hold the switch in. With the switch held in, observe the port lights. The lights for Ports 9 and 10 should illuminate on the MAXserver 1620 and 1640 (ports 7 and 8 on the MAXserver 1604 and 1608 A/B). The port lights should then flash in sequence from 1 to 10 (1 to 8 for MAXserver 1604 and 1608A/B) and then back to 1 again. Port lights 8, 9 and 10 then illuminate (port lights 7 and 8 on the MAXserver 1604 and 1608A/B). When this sequence has completed, release the RESET switch. The MAXserver performs the standard self-test diagnostics. (The self test requires about 20 seconds to complete.) 3. When the RUN light flashes rapidly (indicating that the self test has completed), autobaud any serial port by pressing RETURN a few times at a terminal connected to the port. Once the MAXserver has selected a port speed, it generates the following message: ACCESS SERVER, TYPE 90, REV X ETHERNET ADDRESS 00-DD-01-00-46-DD, PORT 1 CONFIGURATION IN PROGRESS. PLEASE WAIT. 4. Type the password "ACCESS" (note that there is no prompt) and press <RETURN>. The unit displays the menu shown in Figure 40:
150
0038