Page 151
Getting Started with MAXserver Access Servers
Welcome to the Configuration Menu. Access server Configuration Menu 1. Display unit configuration 2. Modify unit configuration 3. Initialize server and port parameters 4. Revert to stored configuration S. Exit saving configuration changes X. Exit without saving configuration changes Enter menu selection [X]:
Figure 40 - MAXserver Access server Configuration Menu
5. Type '1' and press <RETURN>. The unit displays a menu similar to Figure 41.
Display Unit Configuration Menu 1. Initialization record #1 (Enabled) 2. Initialization record #2 (Disabled) 3. Initialization record #3 (Disabled) M. Miscellaneous unit configuration D. Set unit configuration to defaults. X. Exit to main menu Enter menu selection [X]:
Figure 41 - Sample Display Unit Configuration Display
0038
151
Page 152
Getting Started with MAXserver Access Servers
6. Type 'M' and press <RETURN>. The unit displays a screen similar to Figure 42.
Stored Configuration Load status messages: Memory installed: (Found 4 Megabytes)
Enabled 4 Megabytes
New Configuration Enabled 4 Megabytes
(Type any key to continue)
Figure 42 - Sample Miscellaneous Configuration Display The display indicates the amount of installed memory detected by the MAXserver. If you have installed more memory than the display indicates, try re-installing the SIMMs. To exit the Miscellaneous Configuration display, press any key. The Display Unit Configuration menu appears. Type 'X' at the "Enter menu selection" prompt. This returns you to the main menu. Enter 'X' at the "Enter menu selection" prompt. The MAXserver then proceeds to load its software.
Removing SIMMs
+
Before you remove SIMMs, you must configure the MAXserver for less memory, using the Access server Configuration Menu. If you fail to do so, the front panel lights will display an error code the next time you try to initialize the unit. Also, if you have enabled more software features than the MAXserver can support with reduced memory, you will not be able to reinitialize the unit after you remove the SIMMs. To prevent this, configure the software for fewer features prior to removing the SIMMs.
152
0038
Page 153
Getting Started with MAXserver Access Servers
To remove memory from the MAXserver, complete the following steps: 1. Select Option 2 from the Configuration Menu and press <RETURN>. The unit displays the Modify Unit Configuration Menu. 2. Select option M and press <RETURN>. The MAXserver displays a series of prompts. Press <RETURN> at each prompt, until you see the following message: Total installed memory in megabytes (2,4,6,8) [4]: The number in the square brackets [ ] indicates the amount of installed memory for which the MAXserver has been configured. 3. When you see the prompt, enter the amount of memory the MAXserver will have after you remove the SIMMs, and press <RETURN>. 4. Type 'M' and exit to the main menu. The unit displays the Configuration menu. Enter 'S' at the "Enter menu selection" prompt to save changes and exit. The MAXserver prompts: SAVE CHANGES AND EXIT (Y,N) [Y]? 5. Type 'Y' and press <RETURN>. When the MAXserver has saved the changes, you see this prompt: CHANGES MADE.
EXIT CONFIGURATION MENU (Y,N) [Y]?
6. Type 'Y' and press <RETURN>. 7. After you have configured the MAXserver for less memory, proceed to the following section to physically remove the SIMMs.
Removing SIMMs from the MAXserver You must remove either two or four SIMMs. If you want to remove two SIMMs and four are installed, remove the SIMMs from sockets 3 and 4. 1. Follow steps 1 through 5 under “Installation” in this section. 0038
153
Page 154
Getting Started with MAXserver Access Servers
2. To remove the SIMMs from the sockets, pull the retainers that hold the SIMM outward (see Figure 43).
Pull retainers outward.
1
30
Figure 43 - Removing SIMMs
3. Pull the SIMM toward you, then up. (Basically, you reverse the steps shown in Figure 37.) 4. Replace the MAXserver cover, and secure it with the four screws you removed previously. 5. Return the unit to the rack or flat surface from which you removed it, and plug it back in.
154
0038
Page 155
Getting Started with MAXserver Access Servers
Technical Specifications Item Terminal Signals
Terminal Cabling
Transmit Data, Receive Data, Transmit Ground, Receive Ground, Data Set Ready/Data Carrier Detect (DSR/DCD), Data Terminal Ready (DTR), Ring/Clear-to-Send (RNG/CTS), and Ready-toSend (RTS). Supports concurrent modem control. Modular RJ-45
Cable Lengths - 1620 Serial Speed
Maximum Length
>9.6 kbps 19.2 kbps or less 38.4 kbps 57.6 kbps 115.2 kbps Cable Lengths - 1640 Serial Speed
900 meters(3000 feet) 305 meters (1000 feet) 152 meters (500 feet) 60 meters (200 feet) 30 meters (100 feet) Maximum Length
>9.6 kbps 19.2 kbps or less 38.4 kbps 57.6 kbps Serial Speed
900m (3000 feet) 305 meters (1000 feet) 152 meters (500 feet) 60 meters (200 feet) Maximum Length
Cable Lengths 1604/1608B
Flash Card Interface Serial Line Speed Number of Serial Ports
0038
Description
>9.6 kbps 3000 ft/900m 19.2 kbps 1000ft/300m 38.4 kbps 500ft/150m 57.6 kbps 200ft/60 m 115.2 kbps 100ft/30m Accepts industry standard JEIDA/PCMCIA cards. MAXserver 1604/1608/1620 - 50 to 115.2 Kbps MAXserver 1640 - 50 bps to 56.7 Kbps MAXserver 1604 - 4 ports MAXserver 1608A/B - 8 ports MAXserver 1620 - 20 ports MAXserver 1640 - 40 ports 155
Page 156
Getting Started with MAXserver Access Servers
LEDs
RUN, LAN, Flash Card Status, Console, Port status and Diagnostic LEDs 1-10 (1620/1640) LEDs 1-8 (1608B/1604)
Controls
Run/Reset push button switch
Dimensions Height Depth Width Weight
1640 and 1620 1608B and 1604 4.45 cm. (1.75 in.) 4.1 cm (1.62 in) 30.48 cm. (12 in.) 19.5 cm (7.7 in) 48.26 cm. (19 in.) 23.3 cm (9.9 in) 1640 and 1620 1608B and 1604 3.64 kg. (8 lbs.) 1.7 kg (3.8 lbs. With ext. power supply) 4 MB DRAM, expandable to 8 MB with SIMM memory modules.
Memory Environment
10% to 90% humidity, noncondensing Operating Temperature: 32° - 113° F (0 - 45°C) Storage Temperature: -4 to 140° F ( -20 to 60°C)
Input Voltage
110 - 240 VAC 50 - 60 Hz (All MAXservers)
Power Requirements 1640
1620
1608B/1604
156
42W, 145Btu/hr 0.35 A at 110V (typ), 0.19A at 220V (typ) 32W, 110Btu/hr 0.27 A at 110V (typ), 0.15A at 220V (typ) 25W, 110Btu/hr 0.7A at 120V (typ), 0.3A at 220V (typ)
Minimum Software Requirements
Access Server Software, V5.3 or later for MAXserver 1608A, 1620 and 1640. V6.0.3 or later for MAXserver 1604 and 1608B.
Ethernet Interface
Ethernet/IEEE 802.3 Connection -- 10BASE-T or AUI Transceiver
0038
Page 157
Index
BOOTP
# enabling as a dump protocol, 119
10Base-T connector, 25 bootstrap protocol (BOOTP), 16
10Base-T connectors, 79 broadcasts
10Base-T network cable, 20 for delays, 57
10BASE-T network cable, 141
A
C cables, 21
AC line cords, 26 checking connections, 140
AC power outlets, 26 connecting to RJ-45 jacks, 29
AC power receptacle, 26
DEConnect compatible, 68 adapter wiring, 65
Etherner transceiver, 78 adapters, 64 labeling for identification, 30
ARAP cabling, 74 lengths, 155 areas making your own, 62 modem connections, 73, 74, 76 flash cards, 113 Attachment Unit Interface (AUI), 13 octopus, 68
AUI connector, 25 problems with, 135 autobaud
RTS/CTS flow control, 75 port settings, 32 cabling, 64, 155 autobaud, 83, 150
"octopus", 69 autobauding, 133, 140
DECconnect, 68 autobauding feature, 31 signals, 67 cabling schemes
B baud rates, 15 port settings, 32
0038
XMT, RCV, DCD/DSR, DTR, RING,, 73 cabling types, 60 CARD protocol, 120 157
Page 158
Index (continued)
communication speeds, 15
DEConnect cabling, 68 communication speeds. See also baud
DEConnect connector, 69, 70 rates., 140
DECserver 200 load file, 136 configuration default prompt settings, 46 current unit settings, 85 default settings, 30 customizing, 92 defaults reverting to last saved values, 104 gateway IP address, 116 using ControlPoint, 18 image protocols, 93 using FocalPoint, 17
IP addresses, 114 configuration data, 95
IP load hosts, 115 configuration menu, 83, 84 protocols, 89 connectors resetting parameters, 117
10Base-T, 25 resetting the unit, 102
AUI, 25 use for servers and ports, 104
ControlPoint configuration, 18 delay rebooting, 57 copying flash cards, 53 diagnostic codes, 141 corrupted data
Directed Trivial File Transfer troubleshooting, 136
Protocol, 82 corrupted load file, 136
Directed Trivial File Transfer
CPU identifiers, 136
Protocol. See DTFTP., 89 display port 0 telnet characteristics, crimping tools, 62
40 crossover cable, 67 crossover cables, 60, 140 display unit settings, 16 distribution panels, 70
D damage during shipping, 20 DB-25 connectors, 64, 70 downloads, 17 DTE devices connecting to MAXservers, 67
DB-25 distribution panels, 71
DTE wiring, 65
DB-25 pin assignments, 67
DTFTP, 88, 89
DCD/DSR flow control, 62 enabling, 120
DCE wiring, 79 158
0038
Page 159
Index (continued)
naming conventions, 98 dump files problems with, 138, 139
TFTP loading, 100 dump protocols, 88, 108, 113 flash cards, 51 enablind/disabling, 119 areas, 113 dump requests, 138 copying contents to another card, 53 dump servers, 137 current settings, 53, 54 dumping methods, 96, 97 deleting contents, 53 loading images, 55
E loading the image file, 51 environment, 156 retrieving load images, 113 environmental requirements, 21 terminating updates, 113 erasing flash cards, 53 error codes, 129, 130, 131, 141
Flash memory cards installing, 23 error messages, 58 flow control, 61 errors
FocalPoint configuration utility, 17 front panel lights, 22 load servers, 135 Ethernet 15-pin AUI connectors, 78
G
Ethernet addresses image file locations, 113 gateway IP addresses, 108 image files, 55 gateways, 100
Ethernet connections, 156
H
Ethernet transceiver cable, 20, 141 extension cables, 70 hardware flow control, 62 extension cords, 26
Help command, 38
F host IP addresses, 108
I file names changing, 52 image filenames load files, 99 defining, 97 filenames load files, 112 0038 image files loading, 55 159
Page 160
Index (continued)
image load methods, 89 image loading terminating, 113 network hosts, 114 IP Addresses for internet access, 30 image loading methods, 92, 94
IP load address, 115
INIT DELAY command, 33, 57, 58
IP load file, 115 initialization records, 81
IP load hosts, 114 initialization records
L creating, 85 current settings, 86
LAN LEDs, 141 displaying, 108
LEDs, 27, 28, 29, 35, 156
ENABLING/DISABLING, 91 error code displays, 131
RESETTING, 91 error codes, 129
INITIALIZE DELAY command, 33 errors, 132 initialize server and port parameters, out-of-band management, 123
104 input voltage, 26 self-test mode, 83 troubleshooting, 128, 129 installation, 20 load file names, 98 installed memory display, 149 load files, 112 internet access IP addresses, 30 IP ADDRESES GATEWAYS, 100 IP addresses current settings, 108 filenames, 112 problems with, 136 load images defaults, 93 configuring, 114 location of, 88 default settings, 31 retrieving from hosts, 113 defining, 99, 115 load offer list, 139 gateways, 108, 116 load offers, 133 host address, 108 load protocols
HOSTS, 100 enabling/disabling, 120 image file locations, 113 load server addresses, 135 image files, 55 load server errors, 135 load servers, 134, 135, 136, 137
160
0038