Page 131
Getting Started with MAXserver Access Servers
Write down the numbers of the error code (the lights that are ON) and contact your NBase-Xyplex Customer Support representative. (In the U.S., call 1-800-435-7997. For International calls, the number is 978-952-4888). Your representative will provide further instructions on how to handle the condition.
Common Error Codes First Error Code: 3, 4, 6, 7 Second Error Code: 3 Problem: The MAXserver has been configured for more memory than is actually installed. Solution: Either configure the MAXserver for less installed memory, using the Access server Configuration menu, or install additional SIMM memory. (The SIMM memory installation should only be performed by qualified personnel.) Use the Modify Unit Configuration option to specify the amount of installed memory. The Configuration menu is described in Chapter 4. First Error Code: 3, 4, 8 Second Error Code: 2, 8 or First Error Code: 3, 4, 6, 7 Second Error Code: 3, 6 Problem: Reinitialize the unit. Solution: Select the Modify Unit Configuration option from the Configuration menu (see Figure 28) to access and modify configuration parameters, or you can reinitialize the unit from Command Line Interface with the following command:
0038
131
Page 132
Getting Started with MAXserver Access Servers
XYPLEX>>INITIALIZE DELAY 0
Power Up and Re-initialization Problems The following list describes the problems you might encounter when you power up or re-initialize a MAXserver. The list includes descriptions of correct operations and possible solutions. CARD light does not go ON Problem: You are trying to load from a Memory card and the CARD light does not go ON. Correct Operation: The CARD light should illuminate for approximately 15 seconds when the MAXserver loads software from a flash card. Possible solutions: If the CARD light does not go ON, make sure that the card is inserted properly. Also, make sure that the MAXserver is configured to load from the Memory card. Use the Configuration menu in Figure 27 to verify. By default, a MAXserver is configured to load from the flash card, however, someone might have changed this setting. CARD light goes ON then OFF quickly Problem: If the CARD light goes ON and then OFF quickly, make sure that the flash card has been initialized. Solution: You can initialize a flash card while it is inserted in the unit by issuing the FORMAT CARD command. Alternatively, if you have a PC with a flash card drive, you can check whether the SYSTEM directory is present on the card. The directory should contain the software image. The filename must be xpcsrv20.sys. Also, the loader file mcffs1.sys must reside in the same directory as xpcsrv20.sys, and must appear before xpcsrv20.sys.
132
0038
Page 133
Getting Started with MAXserver Access Servers
Use the following command to display the contents of the SYSTEM directory: SHOW SYSTEM PARAMETERS
Network Loading Problems Problem: The MAXserver does not appear to load from the network, or is slow to load from the network. Correct Operation: The load server downloads a software image and (optionally) parameters to the MAXserver, over the network, whenever the unit is powered on or re-initialized. After the software and (optionally) parameters have been downloaded from the load server, the RUN light should blink once every second. Then, if you type several <RETURN>s at a terminal connected to any serial port, the following message should appear: WELCOME TO THE XYPLEX ACCESS SERVER. ENTER USERNAME>_ Possible Solutions: The MAXserver generates several messages during the load process, which can help you resolve loading problems. To see the messages, press <RETURN> several times at a terminal connected to a MAXserver serial port, when the unit begins the loading process. (When you do this, the serial port adjusts to the communication speed of the terminal. This process is called autobauding.) The port light should go ON when you press <RETURN>. If you type <CTRL><T> now, the unit will display the load server offer table when it receives load offers. (Only one <CTRL><T> is required.)
0038
133
Page 134
Getting Started with MAXserver Access Servers
Loading Problems Refer to the following message descriptions for assistance in correcting loading problems. Note that each <RETURN> generates a single message. You must press <RETURN> every 5 - 10 seconds to receive updated messages. Also, if the load process takes place very quickly, you might miss some of the messages. Problem: Not Connected to the Network If the MAXserver is not connected to the network, you see one of the following messages when you press <RETURN>: AUTOMATIC NETWORK SELECTION: SEARCHING FOR FUNCTIONAL NETWORK. SEARCHING FOR FUNCTIONAL STANDARD ETHERNET NETWORK. SEARCHING FOR FUNCTIONAL 10BASE-T ETHERNET NETWORK. Problem: No response to a load request Normal Process: A message similar to the following one is displayed while the server is waiting for a response to the load request. REQUESTING NETWORK LOAD SERVICE If this message displays for more than 20 seconds after you type several <RETURN>s, either the MAXserver is not configured on a load server, or it cannot communicate with a load server. If this message does not appear after you type several <RETURN>s, the MAXserver unit could be at fault. Call NBase-Xyplex Customer Support. (In the U.S., call 1-800-435-7997. For International calls, the number is 978952-4888).
134
0038
Page 135
Getting Started with MAXserver Access Servers
Solution: Check that the MAXserver is in the RUN state and that the Ethernet transceiver cable or 10BASE-T network cable is properly installed.
Load Server Errors A message similar to the following one is displayed if the MAXserver has received a load offer from a load server: EVALUATING SERVICE OFFERS If you typed a <CTRL><T> after "autobauding" your terminal, messages similar to the following display when the unit has stopped accepting load offers: Received load service offers: Host Address xx-xx-xx-xx-xx-xx protocol 0809 merit 9C000037 filename XPCSRV20
Up to ten load server addresses are displayed (typically, just one). The MAXserver unit selects the load server with the highest merit value. When the MAXserver chooses a load server, a message similar to this one appears: Access server, Type 86, Rev x.xx.x Ethernet address 08-00-87-xx-xx-xx, port x Currently using initialization record 1 Loading file xpcsrv20 from server xxx.xxx.xxx.xxx, message 1487 Memory Card; Not Installed
Error: Message count stays at zero while you type <RETURN> continuously. Problem: The load server was configured to load the MAXserver unit, but encountered a problem with the load file or directory. Possible Solutions: Check the filename and directory at the load server. Additionally, in some newer VAX/VMSinstallations, the logical name 0038
135
Page 136
Getting Started with MAXserver Access Servers
"MOM$LOADmight not be defined properly. (Refer to the Software Installation Guide for VMS load hosts for more information.) File Loading Errors PROBLEM: ERROR: SERVER XX-XX-XX-XX-XX-XX; FILE ERROR: NOT A LOAD FILE. This message type appears if the load server attempted to load a file image that is incompatible with the MAXserver. (The load file did not have a MAXserver ASCII identification string header.) This can happen if, for example, the file is a DECserver 200 load file. Normal Process: After the MAXserver loads a file, it checks the contents of the file for proper identification and size. Error: Server xx-xx-xx-xx-xx-xx; File error: corrupted data. Problem: The load server attempted to load a file that is compatible with the MAXserver, but the file has been corrupted. Solution: Correct this problem by installing a new file in the load server. Refer to the Software Installation Guide for instructions. Error: Error Server xx-xx-xx-xx-xx-xx; File error: not executable. Problem: No 680xx CPU identifier appears in the file header. This is a NBase-Xyplex file, but it cannot be executed by the server. Solution: Resolve this problem by installing the proper file in the load server. See the Software Installation Guide for instructions. Error: Server xx-xx-xx-xx-xx-xx; Timed out, will retry.
136
0038
Page 137
Getting Started with MAXserver Access Servers
Problem: The MAXserver gave up waiting for the load server to send a load file image. When this happens, the server restarts the load request process. If the message count was not zero, and the "timed out" message was displayed, it is possible that your network experienced communication problems. NOTE: If there is no progress of the message count number beyond zero, a load server problem exists. A network problem probably exists if the message count remains stuck at a number other than zero. Dump Server Errors If a failure occurs during the load process, the server will abort the load process and send a small dump file (approximately 60 bytes) to a server that is configured to accept a dump file. The dump file can be analyzed by NBase-Xyplex to assist you in resolving the fault. Call NBase-Xyplex Customer Support for assistance. Error: Dump service requested, but no dump file can be created Normal Process: The MAXserver uses the same algorithm for the dump server as for selecting the load server. Normally, messages similar to these appear: Access server, Type 86, Rev x.xx.x Ethernet address 08-00-87-xx-xx-xx, port x Requesting dump service
0038
137
Page 138
Getting Started with MAXserver Access Servers
This type of message displays while the MAXserver waits for a response to its dump request. If this message displays for more than 30 seconds after you type several <RETURN>s, the MAXserver is not configured on a dump server, or the MAXserver cannot communicate to a dump server. Refer to the Software Installation Guide for instructions on specifying the proper dump configuration. A message similar to the following one is displayed if the MAXserver received a dump offer from a server. Access server, Type 86, Rev x.xx.x Ethernet address 08-00-87-xx-xx-xx, port x Evaluating dump service offers If you typed a <CTRL><T> after a port speed had been selected, messages similar to these will appear when the unit has stopped accepting dump service offers: Received dump service offers Host Address protocol xx-xx-xx-xx-xx-xx 0809 merit 9C000037 filename
The MAXserver selects the dump server with the highest merit value. If two or more dump servers have the same merit value, the MAXserver will select the first dump server listed. ACCESS SERVER, TYPE 86, REV X.XX.X ETHERNET ADDRESS 08-00-87-XX-XX-XX, PORT X CURRENTLY USING INITIALIZATION RECORD 1 MAINTENANCE DUMP TO SERVER 08-00-2B-05-8B-78,MESSAGE 1487
138
0038
Page 139
Getting Started with MAXserver Access Servers
If a failure occurs during the dump process, the MAXserver will abort the dump and attempt to dump to the next dump server, until the dump server list is exhausted. After the dump process completes, the MAXserver selects the load server with the next highest merit value on the load offer list. If the load list is exhausted, the MAXserver will restart the loading process. Parameter Loading Problems If the MAXserver is configured to load parameters from the network (rather than local Non-volatile storage- NVS), the unit requests a parameter file from the parameter server. If a parameter file is not sent from the server, the MAXserver will wait indefinitely for the parameter file. The following message types can be generated during the parameter file load sequence. The process is similar to the load process: REQUESTING PARAMETER LOAD SERVICE This message (or a similar message) displays while the MAXserver waits for a response to the parameter load request. If this message displays for more than 5 seconds after you type several <RETURN>s, the MAXserver is not configured on a load server for parameter load service. ACCESS SERVER, TYPE 86, REV X.XX.X ETHERNET ADDRESS 08-00-87-XX-XX-XX, PORT X CURRENTLY USING INITIALIZATION RECORD 1 LOADING PARAMETERS FROM SERVER XXX.XXX.XXX.XXX, MESSAGE 1487 MEMORY CARD; NOT INSTALLED
0038
139
Page 140
Getting Started with MAXserver Access Servers
Link L1 refers to the Ethernet transceiver cable or 10BASE-T network cable; that is, the server is loading parameters via the LAN. If the message count remains at zero after you type several <RETURN>s, the load server is properly configured, but does not have a defined parameter file. Loading from the Network Problem: While loading from the network, no messages appear after you type several <RETURN>s. (Note that when the MAXserver is loading from a flash card, you do not see any messages, and cannot access the access server.) Correct Operation: The port normally autobauds to the correct baud rate when you press several <RETURN>s. Once a port speed has been selected, the port light illuminates. In the first 20 seconds after power up, the server runs the self tests and does not respond to the <RETURN>s. Shortly after power up, however, the port displays a message in response to a <RETURN>. Possible Solutions: Determine whether the port is receiving characters properly. Type several <RETURN>s and make sure the PORT light is ON steadily. This indicates that the MAXserver has received characters and selected a communication speed. If the port is receiving characters, the MAXserver might have autobauded to the wrong speed. Press the <BREAK> key to re-initialize the autobaud sequence, then type several <RETURN>s. If the port is not receiving characters, a cable or device problem exists. Try changing the type of cable used (e.g., change from straight-through to crossover). Note that a MAXserver-to-DTE device configuration requires a crossover cable connection. Refer to Appendix B for cable descriptions and order codes.
140
0038