Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 13 of 17

Getting Started With MAXserver Access Servers, Models 1604, 1608A/B, 1620 and 1640, pages 121 to 130

Pages 121 to 130 of 164

The original document is the PDF (902 KB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Xyplex MX-1620

Page 121

Getting Started with MAXserver Access Servers

This example enables MOP as the protocol to use when loading the parameter file from the primary initialization record. XYPLEX>> DEFINE SERVER LOAD PRIMARY PARAMETERS PROTOCOL MOP ENABLED

This example disables the RARP protocol for use when loading the parameter file from the secondary initialization record. XYPLEX>> DEFINE SERVER LOAD SECONDARY PARAMETERS PROTOCOL RARP DISABLED Enabling/Disabling an Initialization Record Use the following command to enable/disable an initialization record: DEFINE SERVER LOADDUMP [record|ALL] DISABLED | ENABLED

Only the primary initialization record is enabled by default. You must enable the other initialization records if you want the access server to use them. All initialization records have default values for the loading and dumping protocols, and the CARD/XMOP/MOP load image filename, whether they are enabled or disabled by default. You cannot disable all three initialization records. If the primary and secondary initialization records are disabled, for example, you cannot disable the tertiary initialization record. If you attempt to do so, the command processor generates an error message.

0038

121

Page 122

Getting Started with MAXserver Access Servers

Examples This command disables the primary initialization record. With this record disabled, the access server first attempts to load or dump using information in the secondary initialization record. XYPLEX>> DEFINE SERVER LOADDUMP PRIMARY DISABLED This command enables all initialization records. XYPLEX>> DEFINE SERVER LOADDUMP ALL ENABLED

122

0038

Page 123

Getting Started with MAXserver Access Servers

Setting Up MaxServer Ports for Out-of-band Management of Console Port Devices This section describes how to set up MaxServer ports for out-of-band management of console port devices. NOTE:

The commands described in this section can only be executed in Privileged mode.

Use the following procedure: 1. Enter the following commands to set up the server IP address and primary gateway address for the MaxServer: DEFINE/SET SERVER IP ADDRESS <internet-address> DEFINE/SET SERVER IP PRIMARY GATEWAY ADDRESS <internet-address>

2. Enter the following commands to disable subnet mask autoconfigure and set up the subnet mask on the MaxServer: DEFINE/SET SERVER IP SUBNET MASK AUTOCONFIGURE DISABLED DEFINE/SET SERVER IP SUBNET MASK <ip-address-mask>

3. Enter the following command to set up the destination port as remote access: DEFINE/SET PORT <port-number> ACCESS REMOTE

4. Enter the following commands to disable autobaud and reset the baud rate at the destination port: DEFINE/SET PORT <port-number> AUTOBAUD DISABLED DEFINE/SET PORT <port-number> SPEED <port-speed>

The port speed setting must match the port speed setting on the

0038

123

Page 124

Getting Started with MAXserver Access Servers attached console port device. 5. Set up the flow control for the destination port: DEFINE/SET PORT <port-number> FLOW CONTROL <flow-control-setting>

The flow control setting must match the flow control setting on the attached console port device. 6. Enter the following command to specify the number of bits per character for data characters that are transmitted and received over the destination port: DEFINE/SET PORT <port-number> CHARACTER SIZE <character-size>

The character size setting must match the character size setting on the attached console port device. 7. Enter the following command to specify the number of stop bits to be used on the destination port: DEFINE/SET PORT <port-number> STOP BITS <bit-value>

The stop bits setting must match the stop bits setting on the attached console port device. 8. Enter the following command to specify the parity for the destination port: DEFINE/SET PORT <port-number> PARITY <parity-setting>

The parity setting must match the parity setting on the attached console port device.

124

0038

Page 125

Getting Started with MAXserver Access Servers

After you have completed this procedure, you are ready to access the out-ofband management console port. Refer to the following section, “Accessing the Out-of-band Management Console Port”, for more information on accessing the out-of-band management console port.

0038

125

Page 126

Getting Started with MAXserver Access Servers

Accessing the Out-of-band Management Console Port There are two methods for accessing the out-of-band management console port. This sections describes both methods.

Accessing from an Ethernet-attached Station Use the following command to access the out-of-band management console port from an Ethernet-attached station: telnet 192.168.5.1:<logical-port-number>

NOTE:

In the above command, logical-port-number is the logical port number of the out-of-band management console port. To determine the logical port number, multiple the physical port number by 100 and add 2,000. For example, the logical port number for physical port number 1 is 2100.

Accessing from a Dumb Terminal Attached to a MaxServer Serial Port Use the following procedure to access the out-of-band management console port from a dumb terminal attached to a MaxServer serial port: 1. Hit the return key several times to autobaud the port and get a Xyplex username prompt. 2. Type any key at the Username prompt. 3. Login to Priviliged Mode via the SET PRIV command. 4. Enter a password of SYSTEM.

126

0038

Page 127

Getting Started with MAXserver Access Servers

5. Enter the following command: TELNET 192.168.5.1: <logical-port-number> In the above command, logical-port-number is the logical port number of the out-of-band management console port. To determine the logical port number, multiple the physical port number by 100 and add 2,000. For example, the logical port number for physical port number 1 is 2100. This command sequence will then connect you to the console of the out-ofband device that's connected to the destination port.

0038

127

Page 128

Getting Started with MAXserver Access Servers

Troubleshooting Refer to this section if you experience a problem with your MAXserver. This section describes:

·

How to troubleshoot startup and loading problems

·

What to do if the LAN light on the front panel goes out

·

How to reset the MAXserver

Startup/Loading Problems Refer to this section if you have powered up the MAXserver or re-initialized the unit and the front panel lights do not behave as follows after several minutes:

·

RUN light flashes slowly

·

LAN light flashes as Ethernet packets are received

Normally, the light pattern appears as follows when you power up the MAXserver, or re-initialize the unit: 9. All lights ON for approximately one second. (The MAXserver is testing the lights.) 10. Each port light goes ON in order – left most to right most. (The MAXserver is running a self test.) 11. The RUN light flashes rapidly. (The self test has completed.) 12. The LAN light goes ON. (The MAXserver is starting the software loading process.)

128

0038

Page 129

Getting Started with MAXserver Access Servers

13. The CARD light goes ON for approximately 15 seconds if the unit is loading from a flash card. (The MAXserver is accessing the flash card. Do not remove the card while the CARD light is ON.) 14. The RUN light flashes rapidly and the LAN light flashes as Ethernet packets are received. (The MAXserver is loading, or trying to load, software.) 15. When loading from a flash card, or when using another MAXserver as a load server, Port lights 8 - 1 go ON, sequentially. Then, lights 8 - 1 go OFF. (The MAXserver has finished loading the software image, and is decompressing it.) 16. When the MAXserver has finished loading its software, the RUN light flashes slowly and the LAN light flashes as Ethernet packets are received.

Startup Error Codes If front panel lights do not behave as described in the previous section when you power up or initialize the MAXserver, the unit might be displaying an error code. A special pattern of diagnostic codes indicates that a hardware or software error has occurred. Figure 35 shows how the diagnostic code; appears on the MAXserver front panel lights.

+

0038

Only Port LEDs 1 through 8 are used to display self-test error codes.

129

Page 130

Getting Started with MAXserver Access Servers

Self-test failure occurs. LEDs flash 10 times, very quickly.

First Error Code

1 2

3

4

5

6

7 8

6

7

User records error code 78

LEDs flash sequentially

Second Error Code

1

2

3

4

5

8

Sequence repeats continuously

User records error code 24678

0 = Off 1 = On

Figure 35 - Sample Error Code Display

130

0038