Page 241
G. ^Bxx Command Summary Cmd.
Description / Options
^B00
Set/Reset Memory Partition Where: [,type]
^B01
^B00[,type][,source] or ^B00,R
Data Type: Offers the following options: ,A1 Include Records that Match Alarm Filter 1 (or) ,A Include Records that Match Alarm Filter 1 ,A2 Include Records that Match Alarm Filter 2 ,ALM Include All Alarm Records from both Filters ,STD Include Non-Alarm (Standard) Records (or) ,D Include Non-Alarm (Standard) Records
[,source]
Source Port: Offers the following options: ,PA Include Records Received via PBX Port A ,PB Include Records Received via PBX Port B (Not Available on NLJ-VIP Models.) ,PX Include Records Received via the AUX Port (Not Available on NLJ-VIP Models.) ,PI Include Records Received via PBX IP Port.
,R
Release Current Partition: This argument cannot be combined with the [,type] or [,source] arguments.
Enter Data Read Mode ^B01[,type][,source][@n][,n] Where: [,type]
Data Type: Offers the following options: ,A1 Release Records for Alarm Filter 1 Only (or) ,A Release Records for Alarm Filter 1 Only ,A2 Release Records for Alarm Filter 2 Only ,ALM Release All Alarm Records from both Filters ,STD Release Non-Alarm Records Only (or) ,D Release Non-Alarm Records Only ,"clue" Release Alarm Records for "clue" Only
[,source]
Source Port: Offers the following options: ,PA Release Records Received via PBX Port A. ,PB Release Records Received via PBX Port B. (Not Available on NLJ-VIP Models.) ,PX Release Records Received via the AUX Port. (Not Available on NLJ-VIP Models.) ,PI Release Records Received via PBX IP Port.
[@n]
Offset: Release records starting with the "nth" record.
[,n]
Count: Release records in groups of "n".
^B02
Send Next Data
^B03
Display Site ID
^B04
Define Site ID ^B04,site_id Where "site_id" is the desired Site I.D. Message (Up to 32 Characters)
Apx-11
Page 242
PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide Cmd.
Description / Options
^B05
Define End-of-Record Character ^B05[,port][,char] Where: [,port] Input Port: Offers the following options: ,A PBX Port A ,B PBX Port B (Not Available on NLJ-VIP Models.) ,X AUX Port (Not Available on NLJ-VIP Models.) ,I PBX IP Port [,char] EOR Character: If a space character is entered, the EOR character for the target port will be cleared. Re-send Last Data Continuous Binary Block Read ^B07[,type][,source][@n] Where: [,type] Data Type: Offers the following options: ,A1 Release Records for Alarm Filter 1 Only (or) ,A Release Records for Alarm Filter 1 Only ,A2 Release Records for Alarm Filter 2 Only ,ALM Release all Records for both Alarm Filters ,STD Release Non-Alarm Records Only (or) ,D Release Non-Alarm Records Only ,"clue" Release Alarm Records for "clue" Only [,source] Source Port: Offers the following options: ,PA Release Records Received via PBX Port A. ,PB Release Records Received via PBX Port B. (Not Available on NLJ-VIP Models.) ,PX Release Records Received via the AUX Port. (Not Available on NLJ-VIP Models.) ,PI Release Records Received via PBX IP Port. [@n] Offset: Release Records Starting with the "nth" Record. Display Current Alarm Record Exit Command Mode (Disconnect / Hang Up) Set Time / Date ^B11,hh:mm,d,MM\DD\YY Where: hh Is the Hour (00 to 23) mm Is the Minute (00 to 59) d Is the Day of the Week (1=Sun., 2=Mon., 3=Tue., etc.) MM Is the Month (01 to 12) DD Is the Date (01 to 31) YY Is the Year (00 to 99) Display Site ID Message / Alarm Message Display System Status Display PBX Inactivity Alarm Parameters ^B17,1 Display Parameters for Alarm 1 ^B17,2 Display Parameters for Alarm 2 Display Reason for Action
^B06 ^B07
^B08 ^B09 ^B11
^B13 ^B16 ^B17 ^B18
Apx-12
Page 243
Appendices Cmd.
Description / Options
^B19
Display Action Schedule ^B19,1 Display Parameters for Schedule 1 ^B19,2 Display Parameters for Schedule 2 Display Partition Record Count Display Remaining Space Display Memory Capacity / PBX Port Baud Rate Display DIP Switch Settings
^B20 ^B21 ^B22 ^B24 ^B25
Erase Partition Data ^B25 Erase Partition Data ^B25,Y Suppress "Sure" Prompt, Erase Partition Data
^B26
Display Separator Line
^B27
Enter Test Message Mode
^B28
Enter Echo Test Mode
^B29
Enter Pass-Through Mode ^B29,A Pass-Through to PBX Port A ^B29,B Pass-Through to PBX Port B (Not Available on NLJ-VIP Models.) ^B29,X Pass-Through to AUX Port (Not Available on NLJ-VIP Models.) ^B29,I Pass-Through to PBX IP Port ^B29,C Pass-Through to Console Port ^B29,M Pass-Through to Modem Port
^B30
Exit, Return to Command Mode
^B39
Erase All Data ^B39 Clear All Records, Leave Alarm Clue Counters Intact ^B39,Y Suppress "Sure" Prompt, Clear All Records, Leave Alarm Clue Counters Intact ^B39,2 Clear All Records, and Reset Alarm Clue Counters to Zero ^B39,2,Y Suppress "Sure" Prompt, Clear All Records, and Reset Alarm Clue Counters to Zero
^B50
Default Parameters ^B50 Reset Options to Default Parameters ^B50,Y Suppress All Confirmation Prompts, Reset Options to Default Parameters ^B50,2 Reset Options to Defaults, and Erase All Formats, Filter Parameters, and Alarm Clues ^B50,Y,2 Suppress All Confirmation Prompts, Reset Options to Defaults, and Erase All Formats, Filter Parameters, and Alarm Clues
Apx-13
Page 244
PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide Cmd.
Description / Options
^B51
Store Alarm Data ^B51[,port][,file] Where: [,port]
[,file]
Input Port: Offers the following options: ,A PBX Port A ,B PBX Port B (Not Available on NLJ-VIP Models) ,X AUX Port (Not Available on NLJ-VIP Models) ,I PBX IP Port Storage Location: Offers the following options: ,1 Store Alarm Data from this Port in Alarm File ,2 Store Alarm Data from this Port in Standard File ,3 Store Alarm Data from this Port in Both Alarm File and Standard File
^B52
Release / Hold End Data Message ^B52,1 Release End Data Message ^B52,2 Hold End Data Message
^B53
Set Compression Mode ^B53,1 Release Data in Compressed Format ^B53,2 Release Data in Decompressed Format
^B54
Release Data on ^B01 ^B54,1 Release First Group without ^B02 ^B54,2 Wait for Command ^B02
^B55
Strip Non-Printable Codes ^B55[,port][,action] Where: [,port]
[,action]
^B56
Store / Strip Codes: Offers the Following Options: ,1 Store Non-Printable Codes ,2 Strip Non-Printable Codes
Select Data Filters ^B56[,port][,filter] Where: [,port]
[,filter]
Apx-14
Input Port: If this argument is omitted, the command will be applied to PBX Port A by default. Options: ,A PBX Port A ,B PBX Port B (Not Available on NLJ-VIP Models) ,X AUX Port (Not Available on NLJ-VIP Models) ,I PBX IP Port
Input Port: If this argument is omitted, the command will be applied to PBX Port A by default. Options: ,A PBX Port A ,B PBX Port B (Not Available on NLJ-VIP Models) ,X AUX Port (Not Available on NLJ-VIP Models) ,I PBX IP Port Data Filter: Offers the Following Options: ,1 Disable Data Filter at Selected Port ,2 Assign Data Filter #1 to Selected Port ,3 Assign Data Filter #2 to Selected Port
Page 245
Appendices Cmd.
Description / Options
^B57
Enable / Disable XON / XOFF Function ^B57[,port][,action] Where: [,port]
[,action]
Input Port: If this argument is omitted, the command will be applied to PBX Port A by default. Options: ,A PBX Port A ,B PBX Port B (Not Available on NLJ-VIP Models) ,X AUX Port (Not Available on NLJ-VIP Models) ,I PBX IP Port Enable / Disable Action: Offers the Following Options: ,1 Enable XON/XOFF at Selected Port ,2 Disable XON/XOFF at Selected Port
^B59
Line ID Option ^B59,1 Disable Line ID Option ^B59,2 Enable Line ID Option
^B60
Define Console / Modem Port Bits and Parity ^B60[,port][,set] Where: [,port]
[,set]
^B61
Bits / Parity Setting: Offers the Following Options: ,1 Set Selected Port to 7 Bits, Even Parity ,2 Set Selected Port to 7 Bits, Odd Parity ,3 Set Selected Port to 8 Bits, No Parity ,4 Set Selected Port to 7 Bits, No Parity
Define PBX Port Bits and Parity ^B60[,port][,set] Where: [,port]
[,set]
^B62
Port: When this argument is omitted, the command will be applied to the Console Port by default. Options: ,C Set Bits/Parity for Console Port ,M Set Bits/Parity for Modem Port
Port: If this argument is omitted, the command will be applied to PBX Port A by default. Options: ,A PBX Port A ,B PBX Port B (Not Available on NLJ-VIP Models) ,X AUX Port (Not Available on NLJ-VIP Models) Bits / Parity Setting: Offers the Following Options: ,1 Set Selected Port to 7 Bits, Even Parity ,2 Set Selected Port to 7 Bits, Odd Parity ,3 Set Selected Port to 8 Bits, No Parity ,4 Set Selected Port to 7 Bits, No Parity
Select Output Format ^B62,1 Release Data in ASCII Format ^B62,2 Release Data in ASCII Format ^B62,3 Release Data in Binary Block Format ^B62,4 Release Data in Xmodem Format ^B62,5 Release Data in Zmodem Format
Apx-15
Page 246
PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide Cmd.
Description / Options
^B64
Enable / Disable Wrap Around Mode ^B64,1 Disable Wrap Around Mode ^B64,2 Enable Wrap Around Mode
^B65
Select Alarm Filters ^B65[,port][,filter] Where: [,port]
[,filter]
^B66
Input Port: If this argument is omitted, the command will be applied to PBX Port A by default. Options: ,A PBX Port A ,B PBX Port B (Not Available on NLJ-VIP Models) ,X AUX Port (Not Available on NLJ-VIP Models) ,I PBX IP Port Alarm Filter: Offers the Following Options: ,1 Disable Alarm Filter at Selected Port ,2 Assign Alarm Filter #1 to Selected Port ,3 Assign Alarm Filter #2 to Selected Port
Enable / Disable Time/Date Stamp ^B66[,port][,action] Where: [,port]
[,action]
Input Port: If this argument is omitted, the command will be applied to PBX Port A by default. Options: ,A PBX Port A ,B PBX Port B (Not Available on NLJ-VIP Models) ,X AUX Port (Not Available on NLJ-VIP Models) ,I PBX IP Port Enable / Disable Time/Date Stamp: Offers the Following: ,1 Disables Time/Date Stamp at Selected Port ,2 Enables Time/Date Stamp at Selected Port ,3 Enable Long Format Time/Date Stamp at Port
^B67
Set Auto Delete Option ^B67,1 Disable Auto Delete Option ^B67,2 Enable Auto Delete Option
^B68
Set Command Echo ^B68,1 Disable Command Echo ^B68,2 Enable Command Echo
Apx-16
Page 247
Appendices Cmd.
Description / Options
^B70
Enable / Disable Immediate Callout and 80% Full Alarm ^B70 Disable Immediate Callout and 80% Full Alarm ^B70,I Enable Immediate Callout ^B70,I,1 Enable Immediate Callout ^B70,I,1,1 Enable Immediate Callout ^B70,I,1,2 Disable Immediate Callout ^B70,I,2,n Define Immediate Callout Number (where n = Immediate Callout Number) ^B70,I,2,[Space] Clear Immediate Callout Number ^B70,% ^B70,%,1 ^B70,%,1,1 ^B70,%,1,2 ^B70,%,2,x
^B70,%,3,n ^B70,%,3,[Space] ^B70,%,4,PagerID ^B70,%,4,[Space] ^B70,%,5,PagerID ^B70,%,5,[Space] ^B70,%,6,PagerID ^B70,%,6,[Space] ^B70,%,7,message ^B70,%,7,[Space] ^B70,%,8,1 ^B70,%,8,2 ^B70,%,9,cmds ^B70,%,9,[Space]
Enable 80% Full Alarm Enable 80% Full Alarm Enable 80% Full Alarm Disable 80% Full Alarm Define Alarm Action, where x is the desired action and 1 = None, 2 = Callout, 3 = Alpha Page, 4 = Numeric Page, 5 = SNMP Trap, 6 = Output Contact Action, 7 = Console Action Define number for 80% Full callout or page (where n is the desired phone number) Clear 80% Full Callout Number Define Pager ID Number 1 for 80% Full Alarm Clear Pager ID Number 1 Define Pager ID Number 2 for 80% Full Alarm Clear Pager ID Number 2 Define Pager ID Number 3 for 80% Full Alarm Clear Pager ID Number 3 Define 80% Full Alarm Message Clear 80% Full Alarm Message Enable Auto Execute Function for 80% Full Alarm Disable Auto Execute Function for 80% Full Alarm Define Auto Execute Command String for 80% Full Alarm Clear 80% Full Auto Execute String
^B71
Set DLE Stuffing Option ^B71,1 Disable DLE Stuffing Option ^B71,2 Enable DLE Stuffing Option
^B72
Display Time, Day, Date
^B73
Send Binary Information Block
^B74
Save / Recall Parameters ^B74 Save Current Parameters to Flash Memory ^B74,1 Save Current Parameters to Flash Memory ^B74,2 Recall Parameters from Flash Memory ,Y (Optional Argument) Suppress "Sure?" Prompt
^B75
Enable / Disable "Sure?" Prompt ^B75,1 Disable "Sure?" Prompt ^B75,2 Enable "Sure?" Prompt
Apx-17
Page 248
PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide Cmd.
Description / Options
^B76
Release Remote Partition ^B76 Release Console Port Partition ^B76,c Release Console Port Partition ^B76,m Release Modem Port Partition ^B76,T1 Release Partition for Telnet Port 1 ^B76,T2 Release Partition for Telnet Port 2 ^B76,T3 Release Partition for Telnet Port 3 ,Y (Optional Argument) Suppress "Sure?" Prompt
^B77
Define Modem Initialization Message ^B77,init Defines "init" as the Modem Initialization Message
^B78
Display Modem Message
^B79
Define / Display Passwords ^B79 Displays Supervisor Level Password ^B79,pass Defines "pass" as the Supervisor Level Password ^B79,1,pass Defines "pass" as the Supervisor Level Password ^B79,2 Displays the User #1 Password ^B79,2,pass Defines "pass" as the User #1 Password ^B79,3 Displays the User #2 Password ^B79,3,pass Defines "pass" as the User #2 Password
^B83
Display Alarm Clue Summary ^B83,1 Display Clue Summary for Alarm Filter 1 ^B83,2 Display Clue Summary for Alarm Filter 2
^B84
Clear Alarm Condition ^B84 Clear Alarm Condition ^B84,y Clear Alarm Condition, Suppress "Sure?" prompt
^B86
Reset Alarm Clue Counters ^B86,clue Reset Counter for "clue" only ^B86,*,A1 Reset All Counters for Alarm Filter 1 ^B86,*,A2 Reset All Counters for Alarm Filter 2 ^B86,* Reset All Counters for Alarm Filters 1 and 2
^B89
Test Alphanumeric Pager ^B89,1 Test Alphanumeric Pager
Apx-18
Page 249
Appendices Cmd.
Description / Options
^B90
Reset Modem Port / Define Modem Communication Parameters Reset Modem Port: Uses the Following Formats: ^B90 Reset Modem Port ^B90,Y Suppress "Sure" Prompt, Reset Modem Port Configure Modem Port: Uses the Following Format: ^B90[,baud][,parity][,data][,stop] Where: [,baud]
^B91
Baud Rate: Can be any standard rate from 300 bps to 115.2 Kbps. If an asterisk is entered, the port will be set to the default modem port baud rate (57.6 Kbps).
[,parity]
Parity Bits: Offers the Following Options: ,N No Parity ,O Odd Parity ,E Even Parity
[,data]
Data Bits: Offers the Following Options: ,7 Seven Data Bits ,8 Eight Data Bits
[,stop]
Stop Bits: Offers the Following Options: ,1 1 Stop Bit ,2 2 Stop Bits
Define Console Port Communication Parameters ^B91[,baud][,parity][,data][,stop] Where: [,baud]
Baud Rate: Can be any standard rate from 300 bps to 115.2 Kbps. If an asterisk is entered, the port will be set at the default rate specified by Setup Switches 1, 2, and 3.
[,parity]
Parity Bits: Offers the Following Options: ,N No Parity ,O Odd Parity ,E Even Parity
[,data]
Data Bits: Offers the Following Options: ,7 Seven Data Bits ,8 Eight Data Bits
[,stop]
Stop Bits: Offers the Following Options: ,1 1 Stop Bit ,2 2 Stop Bits
Apx-19
Page 250
PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide Cmd.
Description / Options
^B92
Define PBX Port A Communication Parameters ^B92[,baud][,parity][,data][,stop] Where: [,baud]
^B93
Baud Rate: Can be any standard rate from 300 bps to 115.2 Kbps. If an asterisk is entered, the port will be set at the default rate specified by Setup Switches 4 and 5.
[,parity]
Parity Bits: Offers the Following Options: ,N No Parity ,O Odd Parity ,E Even Parity
[,data]
Data Bits: Offers the Following Options: ,7 Seven Data Bits ,8 Eight Data Bits
[,stop]
Stop Bits: Offers the Following Options: ,1 1 Stop Bit ,2 2 Stop Bits
Define PBX Port B Communication Parameters ^B93[,baud][,parity][,data][,stop] Where: [,baud]
Baud Rate: Can be any standard rate from 300 bps to 115.2 Kbps. If an asterisk is entered, the port will be set at the default rate specified by Setup Switches 4 and 5.
[,parity]
Parity Bits: Offers the Following Options: ,N No Parity ,O Odd Parity ,E Even Parity
[,data]
Data Bits: Offers the Following Options: ,7 Seven Data Bits ,8 Eight Data Bits
[,stop]
Stop Bits: Offers the Following Options: ,1 1 Stop Bit ,2 2 Stop Bits
^B94
Enter Monitor Mode ^B94,A Monitor PBX Port A ^B94,B Monitor PBX Port B (Not Available on NLJ-VIP Models) ^B94,X Monitor AUX Port (Not Available on NLJ-VIP Models) ^B94,I Monitor PBX IP Port ^B94,C Monitor Console Port ^B94,M Monitor Modem Port
^B95
Display Program Version
Apx-20