Page 231

A. Specifications A.1. NetLink-VIP Specifications Storage Capacity: Using dual compression, approximate storage capacity is as follows. Capacity may vary with different PBX formats. Memory Size

Approximate Call Record Capacity

512K

16,000

4M

125,000

8M

250,000

16M

500,000

32M

1,000,000

64M

2,000,000

Memory: Flash Memory Coding: 7/8 data bits, even/odd/no parity bit, 1,2 stop bits. Input Port Baud Rates (PBX A, PBX B, AUX Port): All standard rates from 300 bps to 115.2 Kbps. Modem Port Baud Rates: All standard rates from 300 bps to 115.2 Kbps. Console Port Baud Rates: All standard rates from 300 bps to 115.2 Kbps. Connectors: Network Port: 10Base-T Modem Port: Line: RJ11 Jack to Telephone Line. Phone: Not Used. Console Port: RS-232 DCE, DB25 female (modem style). AUX Port, PBX Ports A & B: RS-232 DTE, DB9 male. XON/XOFF or RTS/CTS flow control. All parameters programmable. LED Indicators: ON, RDY, ALM, >0%, >25, >50, >75, FULL, OH, DCD, CP, AUX, A, B Size: 3.45" x 14.75" x 7.75" (H x W x D). Weight: 7.4 lbs. total shipping weight. Power: 115/230 VAC, 50/60 Hz, 12 watts, Auto-sensing voltage. Operating Temperature Range: 50°F to 104°F (10°C to 40°C). Humidity: 20% to 80% RH. Fuse: 250 Volts, 0.125 Amps, Slow Blow. Apx-1

Page 232

PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide

A.2. NLJ-VIP (NetLink Jr.-VIP) Specifications Storage Capacity: Using dual compression, approximate storage capacity is 10,000 to 16,000 records. Memory: Flash Memory. 512K for Data Storage. Coding: 7/8 data bits, even/odd/no parity bit, 1,2 stop bits. Input Port Baud Rates: All standard rates from 300 bps to 115.2 Kbps. Modem Port Baud Rates: All standard rates from 300 bps to 115.2 Kbps. Console Port Baud Rates: All standard rates from 300 bps to 115.2 Kbps. Connectors: Network Port: 10Base-T Modem Port: Line: RJ11 Jack to Telephone Line. Phone: Not Used. Console Port: RS-232 DCE, DB25 female (modem style). PBX Input Port: RS-232 DTE, DB9 male. XON/XOFF or RTS/CTS flow control. All parameters programmable. LED Indicators: ON, RDY, ALM, >0%, >25, >50, >75, FULL, OH, DCD, CP, A Size: 3.0" x 11.0" x 7.5" (H x W x D). Weight: 7 lbs. total shipping weight. Power: 115/230 VAC, 50/60 Hz, 12 watts, Auto-sensing voltage. Operating Temperature Range: 50°F to 104°F (10°C to 40°C). Humidity: 20% to 80% RH. Fuse: 250 Volts, 0.125 Amps, Slow Blow.

Apx-2

Page 233

Appendices

B. Description of System Interfaces B.1. Input Ports (PBX A, PBX B, AUX) (DB9 Male; DTE) Note: NLJ-VIP units do not include PBX Port B or the AUX Port. Pin

Signal

1

Data Carrier Detect (In)

2

Receive Data (In)

3

Transmit Data (Out)

4

Data Terminal Ready (Out)

5

Signal Ground

6

Not Connected

7

Ready to Send (Out)

8

Clear to Send (In)

9

Not Connected

Figure B.1: Data Input Ports (P{BX A, PBX B & AUX)

Apx-3

Page 234

PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide

B.2. Console Port (DB-25 Female; DCE)

B.2.1.

Pin

Signal

2

Receive Data (In)

3

Transmit Data (Out)

4

Request to Send (In)

5

Clear to Send (Out)

6

Data Set Ready (Out)

7

Signal Ground

8

Data Carrier Detect (Out)

20

Data Terminal Ready (In)

Console Port to 25-Pin PC

Figure B.2: Console Port to 25-Pin PC

B.2.2.

Console Port to 9-Pin PC

Figure B.3: Console Port to 9 Pin PC

Apx-4

Page 235

C. Supervisor Functions and User Functions In order to restrict access to sensitive commands, the VIP offers two separate operating modes; Supervisor Mode and User Mode. Supervisor Mode allows access to all command functions, including those used to setup and configure the VIP unit. User Mode allows limited access to command functions; users are able to invoke commands to review status and read data, but are not allowed to change system parameters.

C.1. Security Mode at Start Up When the password feature is enabled, the VIP will display a prompt each time the Command Mode is accessed. If the Supervisor level password is entered at this prompt, the unit will start up in Supervisor Mode. If a User level password is entered, the VIP will start up in User Mode. The VIP provides one Supervisor password and two User passwords. The default Supervisor Password is "SUPER". The default User 1 Password is "SMDR", the default User 2 Password is not defined.

C.2. Dialback Security The Dialback Security feature provides an additional level of security for modem access to command mode functions. When this feature is configured and enabled (Sw6 = UP), the VIP will display a password prompt when contacted via modem. If the caller enters a valid password, the VIP will hang up, and then dial the user-defined dialback number for the password entered. After contacting the dialback number, the password prompt will again be displayed. If the Supervisor Password is entered at this point, the VIP will start-up in Supervisor Mode; allowing access to all menu and command functions. If a User Password is entered at the dialback prompt, the VIP will start-up in User Mode; allowing limited access to command functions.

Apx-5

Page 236

PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide

C.3. Supervisor Mode and User Mode Functions The table below summarizes the functions that are available in each of the two security modes. Menu Function

Supervisor Mode

User Mode

1.

Status Displays

Yes

Yes

2.

Buffer Functions

Yes

User Mode allows access to all Buffer Functions except: 8. "Release Remote Partition"

3.

System Functions

Yes

User Mode allows access to all System Functions except: 2. "Passthrough Mode" 3. "Monitor Mode" 6. "Download Parameters" 7. "Audit Trail Functions" 8. "Upload Firmware"

4.

System Diagnostics

Yes

Yes

5.

^Bxx Command Help

Yes

Yes

6.

Recall Parameters

Yes

No

7.

Save Parameters

Yes

No

8.

Exit Command Mode

Yes

Yes

21. Default Parameters

Yes

No

22. Port Configuration

Yes

No

23. System Parameters

Yes

No

24. Scheduled Actions

Yes

No

25. Alarm Configuration

Yes

No

26. Data Filter Configuration

Yes

No

27. FTP Push Configuration

Yes

No

28. FTP Server Configuration

Yes

No

Apx-6

Page 237

D. Alarm Clue Definition Tips This section describes techniques that can be used to avoid common problems that are often encountered when defining Alarm Clues. To effectively detect Toll Fraud, Alarm Clues must produce an accurate count of calls that match the characteristics of a suspect phone call. Careful planning will allow you to create clues that count suspect calls, and ignore calls you don't need.

D.1. Headers, Banners, and Other "Non-Data" When you examine data produced by the PBX, you will often discover that in addition to call records, the PBX also creates records that do not contain call data. In order to avoid counting this "non-data", clues must be carefully defined to exclude headers and other items. In the example below, several call records are shown along with a header. The PBX might generate this header after every 100 calls to identify the record fields. This is helpful when defining the format, but can also be a nuisance when counting calls. +-----+---+-----+---------------+-----+ TIME EXT DUR NO. DIALED COST +-----+---+-----+---------------+-----+ |09:15|074|01:25|19495869950 |00.35| |09:17|112|00:45|18008547226 |00.00| |09:18|085|00:20|8531212 |00.10| |09:20|124|02:25|19495839514 |00.55| |09:18|091|00:25|411 |00.10|

D.1.1. The Comparative Operators When the comparative operators (>, <, >=, and <=) are used, care must be taken to limit the scope of the comparison. When the VIP compares information in a call record with values indicated in the clue definition, it performs an "ASCII comparison". All ASCII characters are compared, not just numbers. Each ASCII character, (including letters and symbols) has a numerical value. Letters of the alphabet have a higher value than numbers, and symbols have a lower value. Although call records may always have a numerical value in a specific field, "non-data" such as headers and summaries, might have letters or symbols in that field. When creating an Alarm Clue that includes the comparative operators, the VIP must be prevented from counting symbols and alphabetic characters as numerical values. Apx-7

Page 238

PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide

For example, if the variable "B" represents call duration and you wish to check for calls lasting longer than 15 minutes, the definition would include the phrase "B>15:00". Unfortunately, this would also count headers that have alphabetic text in the call duration field. If your Alarm Clues are also counting non-data, the techniques described in the following sections can be used to obtain a more reliable count. D.1.1.1. Limit Comparisons When comparative operators are used, values can be defined as a range between two numbers, rather than an open ended range. In other words, if a "Greater Than" operator is used, it can be matched with a "Less Than" operator in order to limit the scope of the comparison. Example: Define a clue that counts calls placed after 5:00 pm (17:00). Assume that the variable "A" represents the time the call was placed. The most direct way to define match parameters is as follows: A>17:00

However, when the clue is defined this way, headers and summaries with alphabetic characters in the "A" field will also appear in the count. To prevent the clue from counting "non-data", the "A" variable can be defined as a range as shown below: A>17:00*A<99:99

This definition would prevent the clue from including "non-data" records that have alphabetic characters in the "A" field, since alphabetic characters would have a value higher than 99:99. D.1.1.2. Exclude Non-Data Characteristics Another way to eliminate non-data from the count is to define the clue in a manner that excludes the characteristics of headers and call accounting summaries. If you examine the data generated by the PBX, there is usually a factor which differentiates non-data from call records. In some cases, call records will always begin with a specific character, and non-data will omit this character. In other cases, non-data will have a specific text item in a field, where call records will have a numerical value. Once you have determined a factor that differentiates between non-data and call records, it is relatively simple to define clues that exclude the non-data. Example: Define a clue that counts calls lasting three minutes or longer. Assume the variable "B" represents the call duration. The most direct way to define this clue is as follows: B>=03:00 Apx-8

Page 239

Appendices

However, when the clue is defined this way, headers and summaries with alphabetic characters in the "B" field would also appear in the count. In order to exclude undesired records, assume you have determined that call records always begin with the character "|" (vertical bar). In order to use this knowledge in the clue definition, you would first re-define the format to include the variable "L" to represent the first character in the record, and then re-define match parameters as follows: B>=03:00*L=|

This definition would exclude headers and summaries by only counting records that begin with the "|" (vertical bar) character. D.1.2. Exact Match with PBX Call Record Format Both the Alarm Filter Format and the Alarm Clue definition must exactly match the data storage format used by the PBX. When your PBX stores data items such as the number dialed or time values, the punctuation and exact characters used will differ from the formats shown in the examples. Prior to defining the Alarm Filter Format and Alarm Clues, it is recommended to carefully examine a number of records. Check each data item to determine the exact format used by the PBX. Later, when the Alarm Filter Format and Alarm Clues are defined, your definition must reflect the format used by the PBX.

D.2. Programming Support If you have difficulty defining formats or clues, you can call the service department at Western Telematic, Inc. at (949) 586-9950 or 1 (800) 854-7226, between 8:00 am and 5:00 am, Pacific Time. Any VIP unit configured to allow remote access can be contacted via modem and programmed by WTI service personnel. Before calling, make certain your VIP unit has been allowed to store a substantial number of call records, representative of the type produced by the PBX. Please be prepared to give a description of the clues you need to define.

Apx-9

Page 240

PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide

E. Customer Service Customer Service hours are from 8:00 am to 5:00 pm, Pacific Time, Monday through Friday. When calling, please be prepared to give provide the serial number of the unit, as well as a description of the problem. If the unit should need to be returned for factory repair, it must be accompanied by a Return Authorization Number issued by WTI Customer Service. WTI Customer Service 5 Sterling Irvine, California 92618-2517 Local Phone: (949) 586-9950 Toll Free Service Line: 1-888-280-7227 Service Fax: (949) 457-8138 E-mail: service@wti.com

Apx-10