Page 111
The Alarm Filters (Toll Fraud Detection) DEFINE OR EDIT CLUE: 1. 2. 3.
Clue Name: Threshold: Match Parameters: (Cont.): 4. Action: 5. Phone #: 6. Pager ID 1: 7. Pager ID 2: 8. Pager ID 3: 9. SNMP Mgmt: 10. Output Contacts 1/2/3/4: 11. Message: 12. Auto Execute: 13. Execute Cmds: (Cont.): 14. Send Alarm Records
(undefined) 0 (undefined)
21. Email to:
Email #1
None (undefined) (undefined) (undefined) (undefined) Manager #1 -/-/-/(undefined) Off (undefined)
Enter selection, Press <ESC> to return to previous menu ...
Figure 9.5: Alarm Clue Definition Menu
9.5.1. Alarm Clue Definition To define Alarm Clues, access the Alarm Clue Definition Menu (Figure 9.5) as follows: 1.
From the VIP Main Menu, type 25 and press [Enter] to display the Alarm Configuration Menu (Figure 9.1).
2.
When the Alarm Configuration Menu appears, type 1 (to configure Alarm Filter 1) or 2 (Alarm Filter 2), and then press [Enter]. The Alarm Filter Configuration Menu (Figure 9.2).
3.
From the Alarm Filter Configuration Menu, type 3 and press [Enter]. The Alarm Clue Definition Menu (Figure 9.5) will appear.
As described in Section 9.2, from the Alarm Filter Configuration menu, type 3 and press [Enter]. The Alarm Clue Definition menu will be displayed as shown in Figure 9.5. The Alarm Clue Definition Menu includes the following: 1.
Clue Name: This name is used to reference a specific clue when reviewing, altering, or deleting clues. When data is released, records can also be sorted according to the Clue Name matched. Names can be up to 16 characters long, and cannot include <Esc>, <Null>, or quotation marks.
2.
Threshold: The number of times this type of call must occur in order to trigger an alarm. This value can be any positive whole number from zero to 999,999,999. 9-9
Page 112
PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide
3.
Match Parameters: Defines criteria that determine if each record will be flagged as an alarm. Match Parameters consist of a variable from Alarm Filter Format, a logical operator (see Section 9.6,) and the value that will be matched (e.g. the number dialed). Example: If the Alarm Filter Format assigns the variable "A" to the "Number Dialed" field, then A=5551212 tells the VIP to check this field for the number 555-1212. Note: Match Parameters may reference several variables, may include several operators, and may also include "AND/OR" conditions. Please refer to the examples in Section 9.9.
4.
Action Parameters (Items 4 - 13): These items determine how the VIP will react when the counter for this clue exceeds the threshold value. If default Alarm Filter Action parameters have been defined (Section 9.2.1) each prompt will be configured according to the default. Action Parameters for each Clue can be individually defined, and parameters specified by defaults can also be edited. This allows you to assign different Pager Numbers and etc. to each clue. For more information, please refer to Section 13.
9.5.2. Editing and Deleting Clues The Alarm Filter Configuration menu is used to edit, delete or display parameters defined for each clue. 1.
From the Main Menu, type 25 and press [Enter]. The Alarm Configuration Menu will be displayed.
2.
From the Alarm Configuration Menu, type 1 (for Alarm Filter 1) or 2 (for Alarm Filter 2) and then press [Enter]. The Alarm Filter Configuration Menu (Figure 9.2) will be displayed.
3.
Display Clue Details: To review parameters assigned to each clue, type 2 and press [Enter]. The VIP will list all clue names for this Alarm Filter. Key in the name of the desired clue and press [Enter]; parameters for the specified clue will be displayed.
4.
Edit Clues: To alter an existing Clue, type 4 and press [Enter]. The VIP will list all clues defined for this Alarm Filter. Key in the name of the desired clue and then press [Enter]. The Define/Edit Clue menu will be displayed.
5.
Delete Clues: To delete an existing Clue, type 5 and press [Enter]. The VIP will list all clues defined for this Alarm Filter. Key in the name of the clue that you wish to delete and then press [Enter]. The clue will be deleted. Note: Deleted Alarm Clues cannot be recovered.
9-10
Page 113
The Alarm Filters (Toll Fraud Detection)
9.6. Logical and Relational Operators Variables and operators are combined to form match parameters. Variables are the uppercase letters A through Z, as defined in the Alarm Filter Format. Relational and logical operators are described below. Operator
Function
>
Greater Than
<
Less Than
>=
Greater Than or Equal To
<=
Less Than or Equal To
~
Not. Can also precede other comparison operators (e.g. ~<, Not Less Than).
=
Equal To
$
Contains String. Searches for specified string anywhere in a field
-
(Dash) Wild Card Character
()
(Parentheses) Used to Combine and Prioritize Operations
+ or |
Logical OR Conditions
* or &
Logical AND Conditions
9.6.1. Logical AND/OR Conditions Logical AND/OR conditions are created by including the AND operators, or the OR operators in the Match Parameter definition. 9.6.1.1. Logical AND Conditions The AND operators (* and &) link parameters in a manner where two or more conditions must all be true in order for the call record to flagged and counted. Example: Assume the variable "A" represents the field for the number dialed, and "B" represents the extension number. To define an Alarm Clue that counts calls placed to 555-1111 from extension 013, match parameters would be defined as follows: A=5551111*B=013 or A=5551111&B=013 This Alarm Filter Clue would only count calls that are placed to 555-1111 AND placed from extension 013. Calls to 555-1111 from extension 086 would not be counted, and calls to 555-2222 from extension 013 would also not be counted.
9-11
Page 114
PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide
9.6.1.2. Logical OR Conditions The OR operators (+ and |) link parameters in a manner where any of two or more conditions must be true in order for the call record to be counted. Example: Assume the variable "A" represents the field for the number dialed, and "B" represents the extension number. To define an Alarm Clue that counts calls placed to 555-1111, OR placed from extension 013, match parameters would be defined as follows: A=5551111+B=013 or A=5551111|B=013 This Alarm Clue would count all calls that are placed to 555-1111 OR placed from extension 013. Calls to 555-1111 from extension 086 would be counted, and calls to 555-2222 from extension 013 would also be counted. 9.6.2. The "Contains String" Operator The "Contains String" Operator ($) allows the VIP to search an entire variable field for a given value or text string, without regard for the item's position within the field. For example, assume the variable "A" represents the first eleven characters in the field for the number dialed as shown in Figure 9.6. If Match Parameters are defined as "A$714", then the VIP will search all eleven "digits" of the phone number for the value "714". This Alarm Clue would count any record that contains the string 714 anywhere in the phone number. This would include records where 714 was the area code, and records where 714 was a part of the number dialed. |08:16|075|B.JOHNSON |OUT|17145551212 |00:55|00.00| |08:18|067|R.JONES |OUT|19495557714 |05:36|00.75| |08:20|092|J.SMITH |OUT|18007140000 |11:15|00.00| ----------------------------------AAAAAAAAAAA---------------------
Figure 9.6: Alarm Filter Format; “Contains String” Example
9-12
Page 115
The Alarm Filters (Toll Fraud Detection)
9.7. Real Time Variables Alarm Filter Clues can also include Real-Time variables that monitor the VIP's internal clock and calendar. Real-Time variables do not use the Alarm Filter Format, or monitor the contents of the call record. When Real-Time variables are used, the VIP will check its internal clock and calendar as each call record is received. If the time and/or date matches the Clue definition, the call is flagged and counted. The VIP's internal clock, rather than the contents of the call record, determines whether the record is counted. The following Real-Time variables can be used to monitor the internal clock and calendar. Note: Real Time variables are always entered as lowercase characters. t w d
Time: Tells the VIP to determine the time each record is received. The time is entered in "HH:MM" format, where HH is the hour (00 - 23), and MM is the minute (00 - 59). Day of the Week: Tells the VIP to determine the day of the week when the record is received. The day of the week is entered as a single digit, where 1 = Sunday, 2 = Monday, 3 = Tuesday, 4 = Wednesday, 5 = Thursday, 6 = Friday, and 7 = Saturday. Date: Tells the VIP to determine the date the record is received. The date is entered in "MM/DD" format, where MM is the month (01 - 12) and DD is the date (01 - 31).
Example 1: To create an Alarm Filter Clue that will count call records received on Sunday, match parameters would be defined as w=1. Where w is the Real-Time variable for the day of the week, and 1 indicates Sunday. Example 2: To create an Alarm Filter Clue that will count call records received after 6:00 pm (18:00) or before 7:00 am (07:00), match parameters would be defined as follows: t>18:00+t<07:00 Where t is the Real-Time variable for the time, and + is the logical OR.
Notes: • Real-Time variables are not defined in the filter format. • The match parameter definition can include both Real-Time variables and regular variables, as well as logical and relational operators. • Real-Time variables function independently from the Time/Date Stamp. The Time/Date Stamp does not have to be enabled in order for the Real-Time variables to function. • Values from the internal clock/calendar are not included in the call record, unless the Time/Date Stamp is enabled. 9-13
Page 116
PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide
9.8. Assigning the Alarm Filter to a Port After defining the Alarm Filter, the next step is to assign the filter to one or more input ports. The Port Configuration menus are used to assign one of the available Alarm Filters to each port as described in Section 5.4. Note that Alarm Filters will not function until they are assigned to a port.
9.9. Match Parameter Definition Examples The following examples are based on fictional PBX call record formats. When designing your Alarm Filter, be aware that the record structure will differ from those shown in the examples. When defining the Alarm Filter Format and Match Parameters the following factors must be considered: • Exact Match: Alphanumeric values in parameter definitions must exactly match those found in the call record. If the record shows the time as "09:00", then the match parameters must also list the time as "09:00", and not "0900" or "9:00". • Number of Characters: For any given variable, the number of characters specified in the Alarm Filter Format must exactly match the number of characters indicated in the Match Parameters definition. For example, if the filter format defines the variable "B" as the first seven characters of the number dialed, then the parameter definition must account for all seven characters. • Searching for Operator Characters: When searching for a text string which contains a space or any character that is also one of the VIP's operators (e.g. >, <, or &) a backslash (\) must precede the space or operator. For example, to search for "***Error***", the match parameter would be defined as "\*\*\*Error\*\*\*". Likewise, when searching for "hello there", the match parameter would be defined as "hello\ there". • Variable Case: When defining and using variables, take care to use the correct case. Real Time variables are always entered as lowercase characters; regular variables are always entered as uppercase characters.
9-14
Page 117
The Alarm Filters (Toll Fraud Detection) |08:18|001|VMAIL |IN | |00:20|00.00| |08:20|092|J.SMITH |OUT|18008547226 |01:07|01.30| |08:21|001|VMAIL |IN | |00:15|00.00| -AAAAA-BBB-CCCCC------------DDDDDDD-----------EEEEE-------
Figure 9.7: Alarm Filter Format; Match Parameters Example 1
Example 1: Repeated Attempts to Access Voice Mail This Alarm Clue counts short calls to voice mail. This type of call could indicate that a caller is dialing into voice mail and randomly trying access codes in an attempt to find an outside line. For this example, assume the Alarm Filter Format is defined as shown in Figure 9.7. Note that the first three lines in Figure 9.7 are sample call records, and the fourth line is the Alarm Filter Format. The variables A, B, and D are not used for this clue. Where: CCCCC EEEEE is the first five characters of the username. is the field that lists the call duration.
Match Parameters for this Alarm Clue would be defined as follows: C=VMAIL*E<=00:30 Where: C=VMAIL *
E<=00:30
Counts calls with "VMAIL" in the username field. is the logical "AND" operator. Tells the VIP to count calls which last 30 seconds or less.
9-15
Page 118
PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide |19:18|067|R.JONES |OUT|12145551234 |25:36|04.75| |19:20|092|J.SMITH |OUT|18008547226 |01:07|00.00| |21:21|002|R.JONES |OUT|12135551212 |30:15|05.75| -AAAAA-BBB-CCCCC------------DDDDDDD-----------EEEEE-------
Figure 9.8: Alarm Filter Format; Match Parameters Example 2
Example 2: After Hours Long Distance Calls. This clue counts long distance calls placed after 6:00 pm and before 7:00 am. This type of call could indicate that a hacker has obtained an access code for an outside line and is using the line to dial long distance numbers after work hours. For this example, assume the Alarm Filter Format is defined as shown in Figure 9.8. Note that the first three lines in Figure 9.8 are sample call records, and the fourth line is the Alarm Filter Format. The variables B, C, and E are not used for this clue. Where: A D is the time the call was received or placed. is the first seven digits of the number dialed.
Match Parameters for this Alarm Clue would be defined as follows: (A>18:00+A<07:00)*D=1-----Where: (A>18:00+A<07:00) Counts calls placed after 18:00 or before 07:00. * is the logical AND operator.
D=1------ Counts calls where the first digit of the number dialed is "1". Note that the remaining 6 digits are entered as wild card characters (-).
9-16
Page 119
The Alarm Filters (Toll Fraud Detection) |17:28|067|T.WILLIAMS |OUT|011811234567 |45:36|20.75| |17:20|092|J.SMITH |OUT|18008547226 |01:07|00.00| |17:21|002|P.BROWN |OUT|19495839514 |00:57|00.20| -AAAAA-BBB-CCCCC------------DDDDDDD-----------EEEEE-------
Figure 9.9: Alarm Filter Format; Match Parameters Example 3
Example 3: Lengthy International Calls This clue requires that you are familiar with the average duration of international calls placed in the course of a normal day. For example, if your average international call lasts about 10 minutes, and you are suddenly billed for a two hour call, this could indicate phone abuse. For this example, assume that the Alarm Filter Format is defined as shown in Figure 9.9. Note that the first three lines in Figure 9.9 are sample call records, and the fourth line is the Alarm Filter Format. The variables A, B, and C are not used for this clue. Where: D E is the field that lists the first seven digits of the number dialed. is the field that lists the call duration.
Match Parameters for this Alarm Clue would be defined as follows: D=011----*E>=20:00 Where: D=011---- Counts calls where the first three digits of the number dialed are "011". The remaining 4 digits are entered as wild card characters (-). *
E>=20:00 is the logical AND operator. Counts calls that last 20 minutes or longer.
9-17
Page 120
PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide |08:18|067|R.JONES |OUT| 5553333|05:36|00.75| |08:20|091|R.PETERS |OUT| 19005551212|31:07|41.00| |08:21|002|P.BROWN |OUT| 1900555444411#2|00:57|00.20| ----------------------------AAAAAAAAAAAAAAAAA-------------
Figure 9.10: Alarm Filter Format; Match Parameters Example 4
Example 4: The "Contains String" Operator ($) This clue provides an example of how the "Contains String" operator ($) can search a field for a specific text string, without regard for the string's position within the field. This is useful in cases where the call record includes a field with right justified numbers (e.g. the number dialed). For this example, assume that the Alarm Filter Format is defined as shown in Figure 9.10. Note that the first three lines in Figure 9.10 are sample call records, and the fourth line is the Alarm Filter Format. Where A is the field that lists the number dialed. In this example, the PBX also records digits entered after the call has connected. This is often seen in cases where the caller is prompted to press numbers in order to access a specific department or extension. In the third line of the example, the digits "11#2" represent digits entered after the call was connected. Match Parameters for this Alarm Clue would be defined as follows: A$1900 Where A$1900 tells the VIP to count calls that have the string "1900" anywhere in the "A" field. When the "$" operator is used, wild card characters are not used to fill the remaining digits. Note: When the "Contains String" operator is used, the clue may also count call records that do not fit the intended purpose of the clue. For example, the clue in this example would also count calls to any number that contains the string "1900", such as "555-1900".
9-18