Page 101

The Data Filters

Example 2: Multiple OR Conditions This example shows a Data Filter that uses multiple OR conditions to store call records which conform to one of several listed characteristics. Assume the Data Filter Format is defined as shown in Figure 8.6. |08:16|075|B.JOHNSON |IN | |00:55|00.00| |08:18|067|R.JONES |OUT|19495839514 |05:36|00.75| |08:20|092|J.SMITH |OUT|18008547226 |11:15|00.00| -------AAA--------------------------------------------------------

Figure 8.6: Data Filter Example 2

Where A indicates the field that lists the extension number. Define a Data Filter that will only store records for calls received or placed by extensions 013, 086, 099, or 101. The Data Filter Action would be set at "Store", and Match Parameters would be defined as follows: A=013+A=086+A=099+A=101

Where: A=013

Stores records for calls received or placed at extension 013.

A=086

Stores records for calls received or placed at extension 086.

A=099

Stores records for calls received or placed at extension 099.

A=101

Stores records for calls received or placed at extension 101.

+ + +

Logical OR Logical OR Logical OR

Note: Match Parameters for this Data Filter could also be defined by entering each "A=xxx" expression under a separate clue name. Example 3: Combining Logical AND Conditions and Logical OR Conditions This example combines a logical AND condition and a logical OR Condition. Assume the Data Filter Format is defined as shown in Figure 8.7. |08:16|075|B.JOHNSON |IN | |00:55|00.00| |08:18|067|R.JONES |OUT|19495839514 |05:36|00.75| |08:20|092|J.SMITH |OUT|18008547226 |11:15|00.00| -AAAAA-BBB--------------------------------------------------------

Figure 8.7: Data Filter Example 3

Where: A Is the field that lists the time the call was received or placed. B

Is the field that lists the extension number.

8-11

Page 102

PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide

Given the Data Filter Format shown in Figure 8.7, define a Data Filter that will store records for calls received or placed between 7:00 am (07:00) and 6:30 pm (18:30). In addition, the Data Filter must also store records for calls received or placed by extension 013. The Data Filter Alarm Action would be set at "Store", and Match Parameters would be defined as follows: (A>07:00&A<18:30)+B=013

Where: A>07:00 Stores records for calls received or placed after 07:00. &

Logical AND

+

Logical OR

A<18:30 Stores records for calls received or placed before 18:30. B=013

Stores records for calls received or placed at extension 013.

Note: Parentheses are used to group the two parts of the logical AND condition. Example 4: The "Wild Card" Operator This example shows a Data Filter that uses the "Wild Card" operator. Assume the Data Filter Format is defined as shown in Figure 8.8. |08:16|075|B.JOHNSON |IN | |00:55|00.00| |08:18|067|R.JONES |OUT|19495839514 |05:36|00.75| |08:20|092|J.SMITH |OUT|18008547226 |11:15|00.00| ----------------------------------AAAAAAA-------------------------

Figure 8.8: Data Filter Example 4

Where A represents the first seven characters of the call record field that lists the number dialed. Assume that you need to only store records for long distance calls. The Data Filter Action would be set at "Store". Since long distance numbers begin with the number 1, Match Parameters would be defined as follows: A=1------

Where: A=1------ Stores records for calls dialed to any number that begins with a "1", regardless of the remaining six positions. Note: Since this Data Filter uses only the first position of the "A" field, the remaining six positions (specified by the Data Filter Format) must also be accounted for. The wild card operator (-) is used to fill out the remaining six positions in the "A" field.

8-12

Page 103

9. The Alarm Filters (Toll Fraud Detection) The Alarm Filters allow the VIP to monitor call records, and check for signs of Toll Fraud or other phone abuse. When suspect calls are detected, the VIP can send an SNMP Trap, contact a local PC via the Console Port, dial a modem or pager or send an Email or Text Message. The Alarm Filter has priority over the Data Filter: even if a call is rejected by the Data Filter, it will still be flagged and stored if it matches an Alarm Clue. The VIP features two separate Alarm Filters. Each filter has its own format, variables, and alarm criteria. When two dissimilar PBX units are connected to the VIP, this provides a separate Alarm Filter for each. Each Alarm Filter includes a "Format", and one or more "Clues" with associated "Actions". The Format describes the location of specific data items within each call record. Alarm Filter Clues define the criteria that determine whether or not a record will be flagged and counted. "Actions" determine how the VIP will react when an alarm is generated. Notes: • When the VIP is connected to two different types of PBX units, it is recommended to define a separate Alarm Filter for each PBX. • An Alarm Filter defined for one PBX may not function with another type of PBX.

9.1. Common Types of Suspect Phone Activity The first step in the detection of Toll Fraud, is to determine the type of calls you wish to monitor. The following types of calls may provide an indication of potential Toll Fraud: • Repeated unsuccessful attempts to access voice mail • After-hours long distance calls • After-hours calls to your 800 number • Lengthy international calls • Calls to countries where you don't normally conduct business The VIP can also be programmed to monitor calls that can indicate internal phone abuse. Examples of these types of calls are as follows: • Calls to your competitor's phone number • Extensions with exceptionally high call activity • Calls to "900" numbers All of these call types will have specific characteristics which can be easily recognized when the VIP examines PBX call records. 9-1

Page 104

PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide ALARM CONFIGURATION: ALARMS 1. Alarm Filter 1 2. Alarm Filter 2 3. PBX Inactivity Alarm 1 4. PBX Inactivity Alarm 2 5. 80% Full Alarm: 6. Input Contact Alarm:

Off Off

OUTPUT CONTACTS (IDLE/NO ALARM) 7. Contacts 1/2/3/4: C/C/C/C

DEFAULT ALARM FILTER ACTION 8. Action: None 9. Phone #: (undefined) (Cont.): 10. Pager ID 1: (undefined) 11. Pager ID 2: (undefined) 12. Pager ID 3: (undefined) 13. SNMP Mgmt: Manager #1 14. Output Contacts 1/2/3/4: -/-/-/15. Message: (undefined) (Cont.): (Cont.): 16. Auto Execute: Off 17. Execute Cmds: (undefined) (Cont.): (Cont.): (Cont.): 18. Send Alm Records 19. Email to: Email #1

Enter selection, Press <ESC> to return to previous menu ...

Figure 9.1: Alarm Configuration Menu

9.2. The Alarm Configuration Menu To set-up the Alarm Filters, you must first access the Alarm Configuration Menu. In addition to defining the two Alarm Filters, the Alarm Configuration Menu is also used to access submenus for the PBX Inactivity Alarms, the 80% Full Alarm, and the Input Contact Alarm. The Alarm Configuration Menu is only available in Supervisor Mode. To access the Alarm Configuration Menu (Figure 9.1) from the Main Menu, type 25 and press [Enter]. Items 1 through 6 provide access to submenus for the various alarms. Item 7 selects default settings for the optional output contacts. Items 8 through 17 define Default Alarm Filter Action parameters. 9.2.1. Default Alarm Filter Actions Alarm Action parameters determine how the VIP will react when an alarm is generated. The Default Alarm Filter Actions select parameters that are applied to all newly defined Alarm Clues. This allows the user to assign identical actions to a series of clues without manually entering parameters for each clue. Notes: • Definition of the Default Alarm Filter Action parameters is optional. • Default Alarm Action parameters are only applied to newly defined clues. These defaults will not be applied to PBX Inactivity Alarms, 80% Full Alarm, or Input Contact Alarm. • When new Alarm Clues are defined, the default values can be altered or eliminated, as discussed in Section 9.5.1. 9-2

Page 105

The Alarm Filters (Toll Fraud Detection)

The following Default Alarm Action Parameters are available. 8.

Action: Specifies the default action that will be performed when an alarm is generated. For more information, please refer to Section 13.

9.

Phone Number: The default number that will be dialed when an Alarm Clue generates a callout or page action. Note: For Numeric Paging, this prompt can specify both the Pager phone number and a numeric "message". In this case, the phone number is entered in the following format: PHONENO@MESSAGENO#

Where PHONENO is the pager number, and MESSAGENO is any user-selected number that will notify the receiver that an alarm has occurred. For example, to dial 555-1212 and send the message "111", the phone number would be defined as "5551212@111#". 10. Pager ID 1: The first default Pager ID number. If alphanumeric pager notification is selected, this is the first pager dialed when an Alarm is triggered. The VIP can dial up to three pagers for each clue. 11. Pager ID 2: The second default Pager ID Number. 12. Pager ID 3: The third default Pager ID Number. 13. SNMP Management: The default SNMP Manager, that will receive SNMP Traps generated by Alarm Clues. IP Addresses for SNMP Managers are defined via the Network Port Configuration Menu, described in Section 5.4.5. 14. Output Contacts: The default open/close action that will be performed when an Output Contact action is generated. "C" indicates the contact will be closed, "O" indicates the contact will be opened, and a dash (-) indicates that the status of the contact will not be changed. 15. Message: Defines the default message sent when the alarm action is Alphanumeric Page, Numeric Page, SNMP Trap or Console. 16. Auto Execute: Sets the default state for the Auto Execute feature. When enabled, the VIP will execute the command string defined under item 17 when a Callout or Console action is generated.

9-3

Page 106

PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide

17. Execute Commands: The default Auto Execute command string. This command string will be invoked when Auto Execute is enabled, and a Callout or Console Action is generated. The command string consists of a series of ^Bxx commands, which are listed in the Command Help Screen, and Section 19. Example: To send the Site ID Message and then send all alarm records, the Auto Execute Command String would be defined as "03/01,ALM". Note that the ^B is not included in the command string, and that each command is separated by a slash (/). 18. Send Alarm Record: Enables and configures the "Send Alarm Record" option for the Alphanumeric Page action. When enabled, the VIP will include the record that triggered the alarm in the text that is sent to your Alphanumeric pager. Please consult your pager service when configuring the Maximum Message Length, Multi-Block Message and Strip Control Codes options. Note: The "Send Alarm Record" function applies to the Alarm Filters only. This function is not available to the PBX Inactivity Alarms or the 80% Full Alarm. 19. Email To: Determines the default recipient for emails that are generated by the various alarms. This prompt allows you to select either, both or none of the two email recipients that are defined via the Send Email Configuration Menu, as described in Section 5.4.5.1.

9-4

Page 107

The Alarm Filters (Toll Fraud Detection) ALARM FILTER 1: 1. Define Format 2. Display Clue Details 3. Define Clues 4. Edit Clues 5. Delete Clues 6. Alarm Counter Reset Time:

(undefined)

Enter selection, Press <ESC> to return to previous menu ...

Figure 9.2: Alarm Filter Configuration Menu (Alarm Filter 1 Shown)

9.3. The Alarm Filter Configuration Menus The Alarm Filter Configuration menus (Figure 9.2) are used to set-up the two Alarm Filters. Each filter has its own configuration menu, and both menus are accessed from the general Alarm Configuration menu (Figure 9.1). Both menus include the following options: 1.

Define Format: The Alarm filter Format (see Section 9.4.)

2.

Display Clue Details: This item is used to review the parameters assigned to each Clue.

3.

Define Clues: The criteria that determine if each record should be flagged and counted. Section 9.5 describes Alarm Clue definition.

4.

Edit Clues: Allows the user to edit or alter existing Clues.

5.

Delete Clues: Deletes clues as described in Section 9.5.2.

6.

Alarm Counter Reset Time: Determines the time of day when Clue Counters for this filter will be reset. Each Clue has a counter which determines how many times this type of call has occurred. For example, a Clue may be used to count long distance calls. When the Alarm Counter Reset Time is selected, all counters for this Alarm Filter will be reset to zero at the selected time each day.

9-5

Page 108

PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide

9.4. Defining the Alarm Filter Format The Alarm Filter Format describes the location of various "fields" within each call record. Proper definition of the Format tells the VIP where to look, in order to determine if a record should be counted as a match. Different types of PBX units will produce records with a slightly different structure. In order to define the Alarm Filter Format, you must first examine several records from the PBX in order to determine the exact record structure. After the format is established, the next step is to assign variables to the fields you intend to monitor. The Alarm Filter Format allows definition of up to 26 variables (the uppercase letters A through Z), which indicate specific record fields or locations. These variables are used when defining the Alarm Filter Clues. When defining the Alarm Filter Format, particular attention must be paid to recognize the exact format used by the PBX. For example, if the call record shows the time as "09:00", then the Alarm Filter Format must account for all five digits, including the colon that separates hours and minutes. To define the Alarm Filter Format, proceed as follows. 1.

Activate the Command Mode as described in Section 19.1. From the Main Menu, type 1 and press [Enter] to access the Status Screens. Check the Status Screen for the port you intend to monitor (Port A, Port B, or AUX), and make certain the Time/Date Stamp is Off. The Port Configuration menus are used to enable/disable the Time/Date Stamp as described in Section 5.4. Notes: • If the Time/Date Stamp is On, field locations will be altered when data is released to the polling device. The Time/Date Stamp appends extra characters to each record. This may cause errors in the Alarm Filter Format. Disable this feature prior to storing records that will be used when defining the Alarm Filter Format. • After the Alarm Filter Format is defined, make certain to return the Time/Date Stamp option to the desired setting.

2.

Press [Esc] to return to the Main Menu. Allow the VIP to collect several PBX records.

3.

From the Main Menu, type 25 [Enter] to access the Alarm Configuration menu. When the menu appears, type 1 or 2 (for Alarm Filter 1 or 2) and press [Enter]. The Alarm Filter Configuration menu will appear as shown in Figure 9.2.

4.

From the Alarm Filter Configuration menu, type 1 [Enter]. The Format Definition menu will appear as shown in Figure 9.3.

9-6

Page 109

The Alarm Filters (Toll Fraud Detection) DEFINE FORMAT: In order to assist the user during format definition, several data records and the previous format are displayed below in the following order: Data Records Previous Format

(If available) (If available) Enter new format at cursor. <Space><Enter> to clear. Use upper case letters for fields, '-' between fields

|08:16|075|B.JOHNSON |IN | |00:55|00.00| |08:18|067|R.JONES |OUT|19495839514 |05:36|00.75| |08:20|092|J.SMITH |OUT|18008547226 |11:15|00.00| (undefined) ---------+---------+---------+---------+---------+---------+---------+---------

Figure 9.3: Alarm Filter Format Definition Screen

5.

The format definition menu will show three sample records, followed by the previous format definition. Although the structure will differ for each PBX, records will look something like those shown in Figure 9.4.

6.

Define the Alarm Filter Format: The prompt at the bottom of the menu is used to define the Alarm Filter. a)

Press the dash key to indicate a field position you do not need to monitor. In Figure 9.4, dashes have been entered in the first four fields of the record.

b)

When you reach a field that you need to monitor, key in the variable (any uppercase letter) that will be assigned to that position. For example, to assign "A" to the first seven digits of the number dialed, enter seven A's as shown in Figure 9.4. The same variable is repeated for each position in the field.

c)

When you reach the last position you need to monitor, press [Enter]. The VIP will save the Alarm Filter Format and return to the Alarm Filter Configuration menu.

DEFINE FORMAT:

In order to assist the user during format definition, several data records and the previous format are displayed in the following order: Data Records Previous Format

(If available) (If available)

Enter new format at cursor. <Space><Enter> to clear. Use upper case letters for fields, '-' between fields

|08:16|075|B.JOHNSON |IN | |00:55|00.00| |08:18|067|R.JONES |OUT|19495839514 |05:36|00.75| |08:20|092|J.SMITH |OUT|18008547226 |11:15|00.00| (undefined) ---------+---------+---------+---------+---------+---------+---------+------------------------------------------AAAAAAA

Figure 9.4: Alarm Filter Format Definition Example

9-7

Page 110

PollCat NetLink-VIP & PollCat NLJ-VIP - User’s Guide

9.5. Defining the Alarm Filter Clues Alarm Filter Clues describe specific criteria that the VIP will use to determine if each record should be counted as a match. Up to sixteen clues can be defined for each Alarm Filter. When the Alarm Filter is assigned to an input port, all data received by that port will be monitored. The VIP will scan each record to determine if it matches any of the defined Alarm Clues. Records that match Alarm Clues are flagged and counted. When data is released to the polling device, alarm records can be sorted according to the name of the clue that was matched. When defining Clues, the following factors should be considered: • Clue Name: Names should describe the type of call the clue will monitor. • Threshold Count: The number of times this type of call must occur in order to generate an alarm. • Match Parameters: The qualities that identify a suspect call. For example, long distance calls are easily recognized because they begin with the number one. Call characteristics are expressed in the form of an equation, which includes the following elements: Variable(s): One or more variables from the Alarm Filter Format or one or more Real-Time variables. Variables determine which field(s) will be monitored. For example, the variable may represent the field for the number dialed. Operator(s): One or more logical/relational operators, such as >, <, and = (see Section 9.6). Parameter(s): A description of the characteristics that determine whether each record is counted as a match. For example, calls to a specific phone number, or calls made after a specific time. • Action Parameters: A Series of parameters that determine how the VIP will react when the counter for this clue reaches the defined threshold. The VIP can send an SNMP Trap, call a modem or pager, contact the user via the Console Port, open or close the optional Output Contacts or send an Email or Text Message. For more information on Alarm Actions, please refer to Section 13. Note: The Output Contact option is not available on NLJ-VIP units.

9-8