Page 161

My uploaded data has the old data followed by my new data… •

If you upload your data and fail to delete it from the TriCoder, when you enter DATA COLLECTION mode again, the TriCoder assumes you want to collect more data and append it to the end of the data file that already exists. To avoid this, be sure to press YES when the TriCoder asks if you want to delete the data file. When it asks ARE YOU SURE?, press YES.

I want to read more than one length I 2of 5 bar code… •

To scan any length I 2of 5 bar code, use 00 when setting the 2 of 5 Length. If you are going to do this, you must check the length in DATA COLLECTION to minimize the possibility of partial reads. I 2 of 5 is very susceptible to misreads so using 00 to read all lengths is risky and not recommended.

I need more than 15 characters for upload prefix and suffix to upload multiple operator entered fields that I want outputted with my main field… •

When using Refer-backs, use {2 instead of {02 to refer back to a particular statement. Substitute your statement numbers for the 2 in the example above. You can also use the “None Statement” for additional refer-backs. See Chapter 8; Creating custom programs for details on Refer-backs.

Error messages for special consideration The error messages below relate to problems that can either be solved by resetting the TriCoder or may require repair:

CHECK LITHIUM BATTERY This message indicates a minor memory problem that has occurred in a Flag Byte area monitored by the TriCoder each time the TriCoder is powered up. Further memory loss could have occurred but the TriCoder was not able to detect a bad statement number, invalid entry type etc… The TriCoder corrected the Flag Bytes and is letting you know that the error has occurred. If you get this message you should: 1.

Check the STATUS on the lithium battery to be sure it has at least 20% life remaining.

2.

Check the existing programs, data and tables to be sure some undetected memory loss has not occurred.

3.

This message can occur if both batteries (AA and Lithium) have been removed or if both have been depleted. 14-13

Page 162

If the Lithium battery is OK and other problems appear with your programs, data or tables, call your dealer or Worth Data for an RMA number.

CHANGE LITHIUM BATTERY Your TriCoder’s memory was detected as having been altered. The unit was reset to its original factory default settings. Voice messages are still there but their number assignments have been returned to the factory default assignments. Unless you have removed both types of batteries (or both are dead), call Worth Data for an RMA number to return and fix your unit. If you have removed both batteries, follow the re-initialization procedure (Fail-safe Reinitialization Procedure) outlined at the end of this section.

INCOMPLETE PGM This may not necessarily be bad news. This error can occur by not completing the writing of a program - maybe you were interrupted while writing a program and the TriCoder went into sleep mode after 5 minutes of inactivity. If this happens, the program should be checked by pressing the F1 key while in the program itself. This causes the TriCoder to check the program for valid statement numbers and their references. If you are referencing a statement number that does not exist or is incomplete, trying to power up the TriCoder will result in the INCOMPLETE PGM message. You can check programs quickly by: 1.

Going into PROGRAMMING MODE and choosing to edit the program.

2.

Once in the program, scroll through the statements to see if the program makes sense and still looks reasonable.

3.

Press the F1 key to have the TriCoder validate and check the program.

4.

Follow the instructions for correcting the program in Chapter 8; Creating custom programs.

If the program looks scrambled of not even close to what you expected, you need to reinitialize the TriCoder to its original factory shipped settings as described on the next page.

14-14

Page 163

Fail-safe Re-initialization Procedure Here is a fail-safe way to re-initialize the TriCoder and set it back to the factory defaults: (also useful for deleting a data file and programs no longer needed). 1.

After turning on the TriCoder, answer NO to all prompts until you see NON PORTABLE MODE? KEY [YES/NO]?_ At the NON PORTABLE MODE prompt, press the F1 key.

2.

Press the SHIFT key.

3.

Press the D key. After pressing the D key, you should see the prompt: PLEASE ENTER DIAG. COMMAND_

4.

Press the SHIFT key.

5.

Now press one of the following keys depending on what you want to happen: Press the 6 key to delete only the current data file. Or Press the 7 key to delete programs 1-3. Or Press the 8 key to load default programs, set program voice messages to 00, and leave error voice messages unassigned. Or Press the 9 key to load default programs, sets program voice and error messages to defaults. Or Press the 0 key to load default programs but clear all voice to unassigned and all program voice messages to 00.

6.

Press the F1 key to go back to the opening screen.

14-15

Page 164

Planning for success… Before you set out on your first big inventory or other data collection event, there are a few things you can do to better your chances for success. Planning and testing before the big day can help you avoid headaches as well as numerous calls to tech support. The whole point of using the TriCoder is to reduce data entry errors and speed up the data collection process. Here is a list of things you can do to make sure both of these things actually happen: 1.

Establish communication in non-portable mode first. Don’t collect data and try to upload it without having thoroughly tested your computer interface settings. Keyboard wedge interface users can set their computer interface and test using Non-Portable Mode in any text editor such as Notepad or WordPad. Serial interface users will need to use the Windows programs provided on the TriCoder Utilities diskette.

2.

Use the Default Program #0 or Sample Program #1 if you can. These programs require no special programming and can greatly cut down on the amount of time you will spend getting your application to work correctly.

3.

If you create a custom program, collect and upload a small amount of data before you go for the whole thing. If you have problems with a small amount of data, think of the disaster you would have uploading your entire inventory without proper testing first.

4.

Stop data entry errors at the source by using the TriCoders data integrity features. Using data identifiers, data type checking, minimum and maximum data lengths and table validation and maintenance can greatly reduce operator error. See the section on Programming for details on each of these features.

5.

Use Voice Messages to speed up data entry. With proper planning, voice prompts and error messages can reduce the amount of time the operator has to look at the display, making data collection faster and more efficient.

6.

Use outside help when you need it. You don’t have to be a programmer to write programs for the TriCoder, but if you are a computer novice and are stuck, save time by asking for help. Borrowing a little of a knowledgeable colleagues time or buying a few hours worth of help from a consultant will save you time and money in the long run. If you have technical problems with the TriCoder itself and cannot remedy the problem using the troubleshooting guide in the manual, call your Dealer or Worth Data.

14-16

Page 165

If you have a problem… •

Save the shipping box. If you ever need to send the TriCoder or any of its’ parts back for repair, you will need the original shipping box.

•

If you have a problem with your TriCoder, consult the troubleshooting section of this manual FIRST. If you cannot find the answer here, call your Dealer or Worth Data for help.

•

Before you call your dealer or Worth Data for technical support, have your TriCoder and related equipment in front of you and be prepared to explain your problem in detail to the Technical Support Engineer.

•

The Engineer may ask you to go through some troubleshooting procedures while on the telephone. This will help them determine what is wrong and what the course of action should be. Many problems can be resolved over the telephone and will not require that you return the equipment to us. If you do need to return the TriCoder to Worth Data, the Engineer will issue an RMA number.

•

If you do need to return the TriCoder for ANY reason, you MUST have an RMA number first. Write the RMA number on the outside of the original shipping box and make sure to insure the shipment. All RMAs should be shipped back to the following address unless directed otherwise:

RMA #XXXXXX Worth Data Inc. 623 Swift St. Santa Cruz, CA 95060 831-458-9938

14-17

Page 166

Appendix A

Powering the TriCoder The TriCoder can be powered by batteries or by the 5-volt power adapter included with the unit. The TriCoder also has a programmable automatic shutoff intended to conserve power. The following information explains how to turn the TriCoder ON and OFF, the differences between battery power and wall power, the two different batteries the TriCoder uses and how to change them. The final section of this appendix provides details on both short and long term storage of the TriCoder.

Turning the TriCoder ON and OFF The ON/OFF key on the TriCoder keypad powers the TriCoder ON and OFF whether the TriCoder is using battery power or accessing wall power with the 5-volt power adapter. To use the 5-volt power adapter, plug the power adapter into the wall outlet, then into the TriCoder (the power jack is on the bottom of the TriCoder). Turn the TriCoder on by pressing the ON/OFF key. Whether using batteries or wall power, upon power up the TriCoder displays the following message: DMA TRICODER Xxxxx Y HIT ANY KEY_

Where:

X is W for a TriCoder jumpered for Keyboard Interface or R for a TriCoder jumpered for Serial Interface or K for USB Keyboard upload or H for USB High Speed upload xxxx is the firmware version (i.e. 2002) and Y is the board version (i.e. E)

Pressing a key on the TriCoder keypad takes you to the Mode Menu. If you were in NON-PORTABLE mode when you turned OFF the TriCoder, it will bring you back into NON-PORTABLE mode upon pressing a key. Exit NON-PORTABLE mode by pressing the F1 key on the TriCoder keypad. This will bring you to the beginning of the Mode Menu, displaying the following prompt: DATA COLLECTION? KEY [YES/NO]?

Battery Power and Wall Power For portable use, the TriCoder is usually operated using battery power. Non-portable applications where the TriCoder is stationary typically use the 5-volt power adapter to utilize wall power and conserve batteries.

A-1

Page 167

Wall Power The ON/OFF key powers up the TriCoder once the 5-volt power adapter is plugged in. If accessing wall power with the power adapter, it is critical that you use ONLY the 5-volt power adapter that comes with the TriCoder. DO NOT plug in any other power adapter you may have even if the voltage matches – other specifications may not. Plugging in an adapter other that the correct one can cause SEVERE damage to your TriCoder costing hundreds of dollars to repair or replace.

Battery Power For portable use, there are two levels of batteries used by the TriCoder. Three AA batteries provide the main power for the scanner, display and electrical circuitry. Either alkaline (including Alkaline rechargeables), Nickel Metal Hydride rechargeable batteries or NiCad rechargeables may be used. Nickel Metal Hydride (NiMH) is preferred over NiCad. Alkaline batteries (including Alkaline rechargeables) should provide approximately 20 hours of continuous scanning (without accessing voice messages), as well as retain the data in memory and provide for real-time clock operation for several months before tapping the backup battery source. NiMH or NiCad rechargeable batteries will give approximately 40% less operational time than alkalines. If you are using rechargeable batteries, there is recharging circuitry built in to the TriCoder. To use the recharging circuitry, you must change a jumper inside the TriCoder itself and then plug in our 5v Power Adapter. For best results, use only NiMH rechargeable batteries. By default, the TriCoder is set up to use regular alkaline batteries with the recharging circuitry OFF. Recharging alkaline batteries may cause the batteries to explode and leak battery acid throughout the TriCoder. With JP3 jumper installed, only use rechargeable batteries. The jumper inside the TriCoder is located above left of the POWER jack and is labeled JP3. The jumper must cover BOTH pins in order for the recharging to work. See Appendix F: Jumpers, Switches, and Adjustments for an internal diagram of the TriCoder. Recharging takes approximately 8 hours for a full charge if batteries are fully discharged first. If you are using alkaline batteries (either regular or rechargeables) and have selected the NiCad/Rechargeables setting in the Speaker/Battery setup parameter (See Chapter 6; TriCoder Setup), the TriCoder generates the following error message: Warning Alkaline Batteries Detected Nicads Are Specified Do Not Recharge The TriCoder can detect the battery type (when batteries are new) and compare it to the Speaker/Battery setting. If it detects Alkalines when NiCads are specified, you should NOT use the recharging feature. Make A-2

Page 168

sure the JP3 jumper is not installed and change the Speaker/Battery setting to ALKALINE. Recharging regular alkaline batteries can cause severe damage to the TriCoder. If using rechargeable NiCad or NiMH batteries, be sure to reset Speaker/Batteries from 02 to 03; otherwise, the TriCoder will not know when to tell you to change batteries and it will fail in very strange ways. See Chapter 6: TriCoder Setup - Speaker Battery settings. The second battery is a lithium battery, used for backup of the data in memory and updating of the real-time clock. The battery model is CR2032 3v and is available wherever you can buy watch or camera batteries. This battery should last for approximately 6 months, even if the AA batteries are removed. Even though the lithium backup battery can last for at least 6 months, we recommend not keeping valuable data in the TriCoder any longer than necessary. Upload your data to the computer – do not risk losing data if you don’t have to. Once you have uploaded, back up your data file on a diskette or tape if the information is extremely critical. The TriCoder can detect low AA batteries as well as a low lithium battery. If the TriCoder detects low AA batteries, it displays the following message for 20 seconds, then turns itself off to protect any data that may be in memory: CHANGE BATTERIES UNIT SHUT DOWN_ The TriCoder also has a battery life indicator that can be accessed in NON PORTABLE mode or during Data Collection. To display the remaining battery life of both the AA and the lithium battery (as well as the date, time and remaining memory) press the STATUS key: mm/dd/yy hh:mm nnnk BYTES FREE AAxBAT99% LI - - - - -50% x=a Alkaline batteries specified in TriCoder Setup x=n NiMH or NiCad batteries specified in TriCoder Setup Press the STATUS key again resume processing.

To change the AA batteries: 1.

Turn OFF the TriCoder and unplug the 5-volt power adapter.

2.

Remove the battery holder door on the back of the TriCoder by pressing down on the grooved portion of the door and pushing outward.

3.

Remove the old batteries and insert the new ones, making sure to orient the batteries according to the diagram inside the battery holder. The positive (+) end of the battery should be facing down toward the bottom of the TriCoder.

4.

If using rechargeable batteries and the TriCoder's built-in recharging circuitry, make sure the jumper labeled JP3 is configured correctly. A-3

Page 169

See Appendix F: Jumpers, Switches, and Adjustments for the location of JP3. The jumper should be ON for rechargeable, and OFF for regular ALKALINE. Also make sure you have the TriCoder Setup Speaker Batteries set to 3 for NiCad or NiMH so that the TriCoder will be able to tell you when to change batteries; if you don’t do this, the TriCoder will exhibit very strange behavior when the batteries get too low. 5.

Replace the battery door and turn the reader on using the ON/OFF switch.

Changing the Lithium Battery: 1.

The model of the lithium battery is CR2032 3v. You can find them at most stores that carry watch or camera batteries.

2.

Turn OFF the TriCoder and unplug the 5-volt power adapter.

3.

Open up the TriCoder by removing the 4 screws holding the two halves together. The TriCoder opens like a book, with a ribbon cable connecting the two halves. The lithium battery is located in the lower right hand corner of the left half. See Appendix F: Jumpers, Switches, and Adjustments for the location of the lithium battery.

4.

Remove the old battery and quickly insert the new one.

5.

Close the TriCoder and replace the 4 screws that hold the TriCoder together. Turn the reader on using the ON/OFF switch.

Storing the TriCoder Daily storage of the TriCoder does not require any special care. If the TriCoder is used on a daily basis, the AA batteries should remain in the unit and changed when low. If you are going to store the TriCoder for several months, replace your current AA batteries with brand new AA Alkaline batteries. Storing the TriCoder with AA batteries that have low or no charge will result in the lithium battery being drained after the AA’s are depleted. The SRAM needs small amounts of power to maintain its status, relying first on the AA’s, then on the lithium battery. If both batteries (AA and lithium) are dead, it is likely that programs and data in the TriCoder will be lost. For long-term storage (6 months or more) we recommend that you upload any stored data and programs, then remove both sets of batteries - the AA and the lithium - to prevent any possible damage to the TriCoder due to battery leakage. After removing the batteries, the SRAM will be reset to its original factory settings. If you have removed both batteries and are using the TriCoder for the first time after long-term storage, you will get some LITHIUM BATTERY messages upon power up.

A-4

Page 170

CHECK LITHIUM BATTERY means that data is probably not lost, but, flag bytes that the TriCoder monitors for change have indicated some kind of modification. CHANGE LITHIUM BATTERY means that both programs and data have been lost and the unit has been set back to factory default settings. You will probably see this message if both sets of batteries have been removed.

A-5