Page 41

Leave the cover off of the Base Station and plug in the power supply. You are ready to configure the Base Station using a RF Terminal.

Base Station Setup using the RF Terminal Using a RF Terminal that is on the same frequency as the Base, stand close to the Base Station and turn on the Terminal. The Base Station is setup via the Terminals' keypad by entering Setup Mode from the menu. Turn on the Terminal and press any key. Answer NO to all prompts until you see: SETUP MODE? KEY [YES/NO]?_ Press the YES key. At this point, the terminal will ask for a password: SETUP MODE PASSWORD?_ Enter WDTRI on the keypad. The next item allows you to choose which item to configure: R/F Terminal------->1 R/F Base Setup--->2 Voice Operations->3 Choose 2 for RF Base Setup. If the RF Terminal is communicating with the Base Station, you will see the first Setup Parameter, BAUD RATE displayed on the RF Terminal screen. If you are not communicating with the Base Station, you will see the following message: Transmission Failed. To Retry, Move Closer and Press Enter. F1 to Exit._ Move closer and retry by pressing the ENTER key. If you still fail, check that the Base Station is jumpered correctly, is powered up and is on the same frequency as your RF Terminal. If you still have problems, see the Troubleshooting section of this manual. If you have successful communication, proceed with your Setup. After changing each parameter, press the ENTER key to move on to the next parameter.

2-28

Page 42

Base Station Setup Parameters Typically the Base Station will need no changes.

Baud Rate 300 600 1200 2400 4800 9600 19,200

0 1 2 3 4 5 6

• This is the communication rate between the host computer and the Base Station. The higher the Baud Rate the shorter the distance between your Base Station and host computer. 9600 baud (the default) is typically good for 100-200 feet or more, while 19,200 baud cannot be transmitted more than 50-100 feet. If you are planning to use an extension cable of 80 feet or more, cut all pins except Transmit, Receive, Ground, and Shield. • A lot of your success will depend upon the quality of your cabling and the level of interference from other electrical equipment near the cable. Electric motors (on start-up) can be particularly troublesome. If you need more distance, use inexpensive 422 line-drivers.

Xon/Xoff Sensitive No Yes

0 1

• If the Base Station is set for NO, it transmits ASCII 19 for its' "BASE INITIALIZED" message and ASCII 17 for its' "TERMINAL ID NOT SIGNED ON" message. Unfortunately, these ASCII characters conflict with any multi-user system utilizing the XON/XOFF protocol. • The alternative setting, 1, should be used whenever you are operating on a system that is XON/XOFF sensitive, such as an HP3000 or other minicomputers. It causes the Base Station to transmit ASCII 20 (instead of 19) for the "BASE INITIALIZED" message and ASCII 16 (instead of 17) for the "TERMINAL ID NOT SIGNED ON" message. • The default setting for flow control for a serial port in Windows 95/98/2000/ME is XON/XOFF, so consider using the Alternative Yes setting if running Windows.

2-29

Page 43

Parity None Even Odd

0 1 2

• Set your Parity to match what you are using on your host computer.

Data Bits 7 bits 8 bits

0 1

• Set your Data Bits to match what you are using on your host computer.

Stop Bits 1 bit 2 bits

0 1

• Set your Stop Bits to match what you are using on your host computer.

Base Listening To: Terminals and Relays Relays ONLY (no RF)

0 1

• In small networks, the Base Station will always be listening on the RF channel - setting 0. • In large networks with critical response-time requirements, it is many times advantageous to have the Base Station listening ONLY to Relays. The Base Station then acts as a Relay control unit, passing data from multiple Relays (possibly on different frequencies) to the host computer and back.

Security Code Disabled Enabled

0 1

• If you do not currently have a Security Code set and want to set one, press the CLEAR key, then the 1 key. Set your 3-digit code by scanning the desired characters from the bar coded FULL ASCII MENU. You can choose any 3 characters from ASCII 33 to ASCII 126. If the characters you want to enter are represented on the RF Terminal keypad, you can enter them from the RF Terminal keypad. For example, ASCII 33 ("A") is available on the RF Terminal keypad by pressing SHIFT first, then pressing the # key. ASCII 126, the "~" character is not on the RF Terminal keypad and must be 2-30

Page 44

scanned from the bar coded FULL ASCII MENU. You must press ENTER on the RF Terminal keypad when you are finished entering all 3 characters. • If a Security Code is set on the Base Station, only Terminals with the matching Security Code will be able to communicate with the Base. A RF Terminal working on the same frequency as the Base Station but without the same Security Code is ignored by the Base. Conversely, Base transmissions to a Terminal without the correct Security Code will be ignored. • Once set, Security Codes are only visible in the Base Station Setup - they are not visible in the RF Terminal setup once you have entered them. If you forget which Security Code you need to use, you must look at the Base setup.

Frequency Bank Bank 0 Bank 1 Bank 2 Bank 3 Bank 4

0 1 2 3 4

• Changing the Frequency Bank is only recommended when more than 16 Base Stations are being used. • The Frequency Bank applies only to the US, Canada and Mexico versions (DLC9.nnn) of the RF Terminal and Base Station. This setting allows the available frequencies to increase from 16 to 80. This can only be used in situations where Relay Stations are not being used. If you switch the Frequency Bank on the Base Station, you must change it on the RF Terminal also. Not only must the Frequency Bank match on both the Terminal and Base, but so must the Frequency selected. • Switching banks (to anything other than 0) is rarely needed. Additional banks were added to accommodate merchandise marts where many businesses are located under the same roof. This allows each business to operate on a separate frequency, maintaining privacy and avoiding interference from the other businesses also using RF Terminals. • Relays are supported only on Bank 0.

2-31

Page 45

Finishing up your Base configuration Once you have finished configuring your Base Station, press the F1 key to return to the Setup Menu, then F1 again to get to the SIGN ON? prompt. Unplug the power supply from the Base Station, move JP103 back to the NORMAL position (see diagram at beginning of this section), then replace the cover on the Base Station. Plug the power supply back in to power up the Base. Once the Base Station is powered up, you should be able to SIGN ON from your Terminal. You must always change the jumper and re-power the Base Station for the changes to take effect.

Changing the Base Station parameters from the Host Once a Base Station has been hung from a ceiling or other high place, you don't want to have to get a ladder every time you need to change one of the Setup Parameters on it. To allow for this situation, there is a way to change all of the Setup Parameters except frequency from the host computer. The command for the Base Station Setup follows this format: @@*S b r p d s l aa EOT Where: letter parameter possible values

@@*S message prefix always @@*S b baud rate r p

XON/XOFF Sensitive Parity

0=300 1=600 0=NO d

Data Bits

2=1200 3=2400 1=YES

4=4800 5=9600

2=odd

0=None

1=even

0=7 bits

1=8 bits 1=2 bits s

Stop Bits

0=1 bit l

Listening to:

a future use

0=Terminals and Relays use 0 for present a future use use 0 for present

EOT

Host to Base message terminator always EOT (ASCII 4)

6=19200

1=Relays Only

If the command does not have the exact length of all bytes present and/or any byte does not have a valid value, the command will be ignored. Be careful when using this command as it does change the way you communicate with the Base station. Your program must make the same adjustments immediately in order to resume communication.

2-32

Page 46

Testing the RF link between base station and host Use the following command to test the transmission of data from host to Base and back again to the host: @@*Edataaaaaaaa<EOT> where dataaaaaaaa is any string of data, terminated by EOT. This string should be sent from the host to the Base Station. If the data is received by the Base, it is echoed back to the host in the format: dataaaaaaaa<CR> where dataaaaaaaa is the data string from the original transmission, terminated by a CR (ASCII 13). This test verifies communication in both directions (host to Base, Base to host). • If the data isn’t echoed back, either your host COM port or the Base Station has a problem. Check that the Base Station is NOT jumpered for Programming. JP103 should be set to N, (Normal), not P. If it is set to P, no communication from host to Base and back will take place. • Once you know the Base Station is communicating with the host correctly, compare the frequency of the Base Station with the frequency of the Terminal. Use Site Testing to check the communication of the Terminal to the Base and back. Stay close, make sure no other Terminals are in use, and go to Site Test mode on the Terminal. You should get 96-100% on first try. If you don’t, it’s a good chance your radios need repair. Call Worth Data for an RMA. If you are using PICK or UNIX as your operating system, make sure the Base Station is set to "XON/XOFF Sensitive".

2-33

Page 47

Chapter 3

Operational Theory Before you jump in and start writing a complex host program, it might be nice to be familiar with the theory behind the operation of your RF Terminal. The RF Terminal has three different modes of communication: • Two-Way Mode - the host program transmits requests for data to the terminal via the Base Station. The RF Terminal transmits a response back to the Base Station, which in turn sends the data on to the host program. This is a truly interactive mode allowing you to create flexible programs for a variety of applications that are computer led and controlled. • One-Way Mode - the RF Terminal transmits to the host with only confirmation from the Base Station. The host program receives data from the Base Station as it would any other serial device. The host cannot send data to the terminal; it can only receive information. • Site Test Mode – the Base Station and RF Terminal work together to evaluate the site and determine the best location for the Base Station. The site test evaluates the percentage of successful transmissions on the first and second tries from any given area. The higher the percentage, the more successful your communications will be from that area. This helps you to identify problem areas before you implement your RF Terminal system. At 30 ft., this is also the acid test for suspected bad radios in a base or in a terminal. Let’s start with a discussion of the basic theory behind a Two-Way RF Terminal system.

How the Two-Way RF System works Basic RF System communications… The RF system consists of three components – Host Computer, Base Station and RF Terminal. The Base Station connects to the Host Computer via the serial port. The application running on the Host Computer sends a data prompt to the serial port where the Base Station receives it. The Base Station then transmits the data prompt via radio frequency to the intended RF Terminal. The RF Terminal displays the data prompt on the display and waits for the operator to enter the requested data. Once the operator enters his data, the RF Terminal transmits the data to the Base Station, which in turn passes it on to the Host Computer. The application on the host computer processes the information and sends a new data prompt out to the Base Station and the whole process begins again. 3-1

Page 48

A little more in depth… This RF system’s dialogue is Terminal initiated. The Terminal says, “I’m here, give me something to do. It is not designed for the Terminal to listen all day to see if the host has something for it, unless the host sends out a message such as “STAND BY, PRESS ENTER”. Then the Terminal will go to sleep and wake up every few seconds to see if there is anything to do while displaying the message “WAITING ON HOST PROMPT.” (After the terminal goes to sleep 8 times, it only wakes up and asks every 16 seconds though.) The Worth Data RF system is different from other systems in that our RF Terminal does not constantly “listen” for a data prompt from the host. Other systems are constantly waiting for a prompt from the host, using up valuable battery life. We decided to use a different approach that would help to eliminate unnecessary radio traffic, conserve battery power, and reduce the size of the actual Terminal itself. Here is how it works: Each RF Terminal has a Terminal ID. When the RF Terminal powers up, it asks if you want to SIGN ON? Pressing YES at the SIGN ON? prompt causes the RF Terminal to transmit it’s Terminal ID and a byte of data indicating to the Base Station that it wants to sign on to the system. When the Base Station receives a SIGN ON message from a RF Terminal, the Base Station transmits the SIGN ON information to the host computer. The host computer application can then do one of two things: 1. If it has something for the Terminal to do, it can send a prompt to the Base, which in turn transmits it to the Terminal. The RF Terminal receives the prompt, waits for the operator to enter the requested data, and then transmits the data back to the Base Station. 2. If the host program does nothing within an allotted time, the Terminal displays the message: WAITING ON HOST PROMPT Lets suppose that a RF Terminal and a Base Station have been processing data by sending prompts and data back and forth as described in example 1. The Base Station sends a data prompt to the RF Terminal, the RF Terminal transmits the operator-entered data back to the Base Station. If the host program has another prompt for the terminal, the Base sends it out, repeating the process above. Suppose the host program does not have a prompt ready to send back to the Terminal; the Terminal transmits its data to the Base Station but does not receive a new data prompt. The Terminal then retransmits its data (it thinks maybe the host didn’t receive it) and waits for a response.

3-2

Page 49

The Base Station knows that the data is a retransmission rather than a new data transmission so it sends a message to the Terminal telling it “I have nothing for you from the host, go to sleep”. While in “sleep” mode, the Terminal “wakes” up at specific increasing intervals and asks “do you have anything for me yet”, waiting for either a “go to sleep” message or a new data prompt. These are the “wake up” intervals: Interval

Number of times repeated

½ second

5 times

2 seconds

1 time

4 seconds

1 time

8 seconds

1 time

16 seconds indefinitely - until prompt received

After each delays, the Terminal displays: WAITING FOR HOST PROMPT Waiting ½ second the first time before asking the base “do you have anything for me yet?” is OK for most rapid response host programs. If your host program is slow and doesn’t process your data quickly enough to get a new prompt out to the terminal within 1/2 second, you need to set a new time by specifying a Host Response Delay. Host Response Delay allows you to set a particular delay value that determines when the terminal will check with the Base for a new prompt. This is valuable if you know that your program cannot respond for a certain amount of time. If you know your host program can’t respond for 2 seconds, there is no need for multiple times after ½ second; that creates unnecessary radio traffic that results in unnecessary collisions and a decrease in system response time. It also wastes battery power. Host Response Delay is critical to eliminating contention between multiple terminals on one Base Station. See Chapter 2; RF System Setup for details on setting the Host Response Delay. If a Terminal receives no response at all from a Base Station (no data prompt or “go to sleep” message), it retransmits its data and waits for a response. If the Terminal gets no response after 10 re-transmissions, it displays: TRANSMISSION FAILED HIT ANY KEY_ Pressing a key on the Terminal starts the re-transmission process over again. The RF Terminal will try to retransmit its data, displaying the TRANSMISSION FAILED message after every 10 unsuccessful tries.

3-3

Page 50

How the One-Way RF System works The RF System can be used to perform “dumb” data entry to the computer – you could even use Portkey to transmit the data as though it has been entered from the keyboard. This is useful if you want to enter data directly into an application. This type of data transmission is called One-Way Mode. Once the RF Terminal transmits data to the Base Station, the Base Station acknowledges receipt of the information by echoing back the data to the Terminal that sent it, along with a beep. If the data transmission did not make it through to the Base station after 10 tries, the RF Terminal will give two long beeps and display the following message: TRANSMISSION FAILED TO RETRY, MOVE CLOSER AND PRESS ENTER. F1 TO EXIT. One-Way mode also works well as a “demo” program since it doesn’t require a program running on the host computer or even that the Base Station be connected to the host. If you want data to display on the host computer, simply run a program such as Windows’ Terminal (be sure to disable Xon/Xoff) or our Portkey program (for keyboard emulation). To get into One-Way Mode: At power up, the RF Terminal asks if you want to SIGN ON? KEY [YES/NO]?_ SIGN ON is for Two-Way communication only. Press NO, then press NO again at: SETUP MODE? KEY [YES/NO]?_ When you see: ONE WAY MODE? KEY [YES/NO]?_ Press YES. If the Base Station already has other RF Terminals signed on in Two-Way mode, you will not be allowed into the system. A Base Station must be dedicated to one mode at a time. If the Base Station is dedicated to One-Way mode, you will see the following prompt on the RF Terminal display: Data Received Was Enter Data? Since you have just started your One-Way session, there is no data to display on line #2. Line #3 is now asking you to scan or key data into the RF Terminal. If 3-4