Page 31

2 of 5 Length Default setting Valid entries To read variable length 2 of 5 codes

06 00-98 00

• 2 of 5 is so susceptible to misreads that the RF Terminal adds an additional safeguard - it can be configured to look for fixed-length data only. • The default setting of 06 causes the RF Terminal to read only 2 of 5 codes that are 6 digits in length. To set the RF Terminal to read a different length, scan any two-digit number from the bar pad table. For example, to change the RF Terminal to accept an 8-digit bar code, scan 0 then 8 from the bar pad table. 2 of 5 code must always be an even number of digits so the length setting must always be an even number. • Reading variable length I 2of5 or 2 of 5 codes is to be avoided if at all possible. The 00 setting is supplied for the purposes of reading codes of unknown length, counting the digits and setting the length to the proper number. Bar Codes

MSI and Plessey Disable MSI Enable MSI, 1 Mod 10 check digit Enable MSI, 2 Mod 10 check digits Enable MSI, 1 Mod 11/ Mod 10 check digit Transmit no check digits Transmit 1 check digit Transmit 2 check digits Enable Plessey bar code (mutually exclusive with MSI) Enable LabelCode5 (mutually exclusive w/MSI & Plessey) Enable LabelCode4 (mutually exclusive w/all above)

0 1 2 3 4 5 6 7 8 9

• LabelCode5 and LabelCode4 are proprietary bar code types used by Follet. • If you have enabled the Mod 10 or Mod 11 check digits, they will be transmitted along with your bar code data from the RF Terminal to your host. • For more information regarding MSI or Plessey Code, see Appendix K; MSI Plessey Code.

2-18

Page 32

Bar Codes

Code 93 Enable Code 93 Disable Code 93 Enable Full ASCII Code 93 Disable Full ASCII Code 93

0 1 2 3

• Code 93 is similar in character set to Code 39. See Appendix F; Code 93 for more information. Code 93 is not a commonly used bar code symbology.

Preamble

Other

Preambles are user-defined data that is attached to the beginning of data (bar code or keyed) that is transmitted to the host by the RF Terminal. For example, if you set a preamble of @@ and scanned bar code data of 12345, @@12345 would be transmitted to the host. • By default, the RF Terminal has no preambles configured. Preambles can contain up to 15 characters scanned from the bar coded FULL ASCII Menu. To set a preamble:

•

1.

Scan the Preamble bar code or select Preamble from the keypad menu.

2.

Scan the desired characters (up to 15) from the FULL ASCII Menu.

3.

Scan the SET bar code, or if using the keypad, press ENTER.

4.

To clear the Preamble and return to the default (no Preambles defined), scan CLEAR at step #2, and then continue with your setup.

You can use the Preamble to trim characters from the data you are entering into the RF Terminal. You can trim from 1-15 characters from the data by creating a preamble of: ~x where ~ is ASCII 126 and x is a single hex digit 1-F (correspon-ding to 1-15). Data that is shorter than the trim amount is transmitted without trimming. Preambles trim characters from the front of the data. Here are some examples:

2-19

Page 33

Data

123 12345678 12345678 12345678901 123456

•

Preamble

Data Transmitted

XYZ XYZ123 ~3XYZ XYZ45678 ~9 12345678 ~A 1 ~5 6 Preamble trims leading characters

Using the Bar Code ID feature and the Preamble, you can trim data selectively, trimming characters only on the bar code type specified. To use selective trimming, enter: ~bx where b is the Bar Code ID character (see the Code 128 setup parameter) and x is the number of characters to trim from the front of the data. For example, ~b2~c1 says “trim 2 characters from Code 39 data and 1 character from UPC-A data”. Remember that the Preamble trims leading data.

•

Lastly, the Preamble can be used to check a minimum/maximum data length for bar code data entered. To check for bar code length in the Preamble enter: |nnmm where | is ASCII 124, nn is the two-digit minimum and mm is the twodigit maximum. |0210 would check for a minimum of 2 characters and a maximum of 10. If you try to scan a bar code outside the minimum or maximum lengths, no decode will result. Entering data by keypad is not affected.

Postamble

Other

Postambles are user-defined data that is attached to the end of data (bar code or keyed) that is transmitted to the host by the RF Terminal. For example, if you set a Postamble of @@ and scanned bar code data of 12345, 12345@@ would be transmitted to the host. • By default, the RF Terminal has no Postambles configured. Postambles can contain up to 15 characters scanned from the bar coded FULL ASCII Menu. To set a Postamble: 1. Scan the Postamble bar code or select Postamble from the keypad menu. 2. Scan the desired characters (up to 15) from the FULL ASCII Menu. 3. Scan the SET bar code, or if using the keypad, press ENTER. 2-20

Page 34

4. To clear the Postamble and return to the default (no Postambles defined), scan CLEAR at step #2, and then continue with your setup. • You can use the Postamble to trim characters from the data you are entering into the RF Terminal. You can trim from 1-15 characters from the data by creating a Postamble of: ~x where ~ is ASCII 126 and x is a single hex digit 1-F (correspon-ding to 1-15). Data that is shorter than the trim amount is transmitted without trimming. Postambles trim characters from the end of the data. Here are some examples: Data

123 12345678 12345678 12345678901 123456

Postamble

Data Transmitted

XYZ 123XYZ ~3XYZ 12345XYZ ~9 12345678 ~A 1 ~5 1 Postamble trims trailing characters

• Using the Bar Code ID feature and the Postamble, you can trim data selectively, trimming characters only on the bar code type specified. To use selective trimming, enter: ~bx where b is the Bar Code ID character (see the Code 128 setup parameter) and x is the number of characters to trim from the end of the data. For example, ~b2~c1 says “trim 2 characters from Code 39 data and 1 character from UPC-A data”. Remember that the Postamble trims trailing data. • Lastly, the Postamble can be used to check a maximum character length for data entered. To check for length in the Postamble, enter: |nnmm where | is ASCII 124, nn is the two-digit minimum and mm is the twodigit maximum. |0210 would check for a minimum of 2 characters and a maximum of 10 If you try to scan a bar code outside the minimum or maximum lengths, no decode will result. Entering data by keypad is not affected. .

2-21

Page 35

Characters This setting allows the RF Terminal to output chosen ASCII characters in place of the actual characters entered. For example, if you scanned the number 1 (hex 31) and wanted the RF Terminal to output hex 92 instead, you would enter 3192 for the Characters parameter. This would re-assign the output characters, with the RF Terminal outputting hex 92 every time it sees hex 31. To re-assign characters: •

Scan Characters

•

Scan up to seven 4-digit pairings where the first 2 digits represent the hex number to replace and the second 2 digits represent the hex number to insert. You can have up to seven character re-assignments.

•

Scan SET

You can eliminate the output of a character by using FF as the hex number to insert. For example, if you wanted to eliminate all $, following the above instructions, enter 24FF.

Beep Tone

Speaker

Lowest Low Medium High Highest No Beep Tone

0 1 2 3 4 5

Speaker / Batteries

Speaker

Speaker ON Speaker OFF Alkaline Batteries or Alkaline Rechargeables Nickel Metal Hydride or NiCad Rechargeable Batteries

0 1 2 3

• If you are using the headphone option (T12), you can conserve battery power by turning the Speaker OFF (1). • In order to get an accurate Battery Status reading; you must select the correct battery type. The default is Alkaline (2). Battery Status can be displayed by pressing the STATUS key on the RF Terminal keypad. • Before you can use rechargeable batteries, you must change the JP4 jumper inside the RF Terminal. See Appendix A; Frequency and Jumper Changes for details. 2-22

Page 36

Date/ Time

Date Format US Format European Format

0 1

• The US format of mm/dd/yy is the default setting for all models shipped in the US, Canada and Mexico. • The European format of dd/mm/yy is the default setting for the Australian, UK and European models. • If you switch formats, you must reset the date (SET DATE) in the new format also. Date/ Time

Set Date

For correct date display, the 6-digit date must be set in the date format you plan to use. By default, all US, Canada and Mexico models are using the US date format of dd/mm/yy. If you change the date format, you must re-set the date to match the new format. For example, to set a date of January 20, 1999, you would enter 012099 (US format) or 200199 (European format). The date can be scanned in from the bar coded Setup Menu or entered from the RF Terminal keypad. To display the date during operation, press the STATUS key. Date/ Time

Set Time

The time is set using a 4-digit military hhmm format. For example, to set the time to 3:08 p.m., you would enter 1508. The time can be scanned in from the bar coded Setup Menu or entered from the RF Terminal keypad. To display the time during operation, press the STATUS key. Date/ Time

Display of Year 2 digit 4 digit

0 1

• By default, the RF Terminal is configured to display and transmit the year in a 2-digit format; i.e. 1999 would transmit and display as 99. • Before you change the RF Terminal to display a 4-digit year, i.e. 1999, make sure that the software receiving data from the RF Terminal is set up to accept a 4-digit year.

2-23

Page 37

Voice Message Partitions

Other

This parameter partitions the total amount of voice messages into different message lengths. The default setting is: 303015 xx yy zz where: xx is number of ½ second messages yy is the number of 1-second messages zz is the number of 2-second messages The total time allotted must not exceed 75 seconds. To change the partitions, scan or enter 6 digits total; 2 for the number of ½-second messages, 2 for the number of 1-second messages and 2 for the number of 2 second messages. See the default setting as an example. WARNING: changing the Voice Message Partitions parameter after you have recorded messages could result in having to re-record some of them; they would still be there but longer messages may get cut up and shorter ones combined.

Shut Down Time

Other

By default, if the RF Terminal is inactive (no keystrokes or scanning) for more than 5 minutes, it will shut itself down in order to conserve batteries. This includes SIGNING OFF if appropriate. To resume operation, you must turn the RF Terminal back on using the ON/OFF key. To change the amount of time the RF Terminal waits before shutting down: • •

Scan Shut Down Time Scan two digits - the default is 05 (5 minutes)- to correspond to the length of time in minutes. For example, 01 would be 1 minute.

If you want to prevent the RF Terminal from shutting off automatically at all, set the Shut Down Time to 00.

2-24

Page 38

Laser Scanner Options

Other

None Double Decode 4.5 second laser beam

0 1 3

Transmit EAN-13 normally Transmit EAN-13 in ISBN format Transmit UPC-A normally Transmit UPC-A in EAN-13 format (with 0 flag character)

C D E F

• By default, the RF Terminal has no special laser options set. If any of the features below seem to fit your situation, set them appropriately. Settings C through F are not laser-dependent and are for UPC/EAN bar code types only. See the UPC/EAN parameter for more information • Double Decode is there to minimize the possibility of misreads when scanning very poor quality bar codes. This option forces the RF Terminal to keep reading until it gets two results that are identical. This "double scan checking" takes longer but will minimize misreads since it must get the same result twice before considering it a "good" read. • 4-second laser beam increases the amount of time the laser beam is activated, giving the laser more time to try and read a code. This option is useful for trying to read poor quality code. Using the 4-second laser beam with long range lasers give the operator more time to aim the laser properly at a distant bar code (usually using the "marker" beam). The default beam time is 2 seconds.

Reset While in Setup Mode, DO NOT scan the RESET bar code unless you want to set all of the RF Terminal setup parameters back to the factory default settings. Scanning RESET will erase all changes you have made.

2-25

Page 39

The following serial parameters Baud Rate, Parity, Data Bits, and Stop Bits apply only to firmware updates and a portable printer such as the Cameo and Encore printers.

Baud Rate

RS232

300 600 1200 2400 4800 9600 19,200

0 1 2 3 4 5 6

Parity

RS232

None Even Odd

0 1 2

• None is generally used with 8 data bits, Even or Odd parity with 7 data bits.

Data Bits

RS232

7 bits 8 bits

0 1

Stop Bits

RS232

1 bit 2 bits

0 1

Protocol

RS232

None XON/XOFF Maintain backward compatibility for illegal statement handling Illegal statement handling for current versions

0 1 E F

• Settings 0 and 1 pertain to use of a serial Printer with your RF Terminal. Use setting 1 for XON / XOFF if your serial Printer supports it. • Settings E and F pertain to the way the RF Terminal handles illegal statements coming from the host computer. RF Terminal software versions prior to 9.059 did not handle illegal statements the same way as current versions. This setting is really only applicable if you had written your host program to be compatible with RF Terminal versions prior to 9.059, are adding current version Terminals to the system, and need to maintain backwards compatibility. 2-26

Page 40

Base Station Setup In order to minimize the possibility of accidentally changing the setup of a Base Station when you really meant to change the RF Terminal, the Base Station cannot be set up from the bar coded Setup Menu. The Base Station can only be setup from a RF Terminal keypad and requires a jumper change inside the Base Station before you can do so. We made changing Base Station parameters difficult on purpose; any mistake can cut off communication with the host computer and bring your system to a halt. As a safeguard, we suggest turning off all other Base Stations or moving to an isolated area to setup a new Base Station.

Preparing the Base Station for Setup Before you can set parameters on the Base Station, you must make a hardware change on the Base Station itself. 1. Have all current RF Terminal users SIGN OFF the system. 2. Unplug the Base Station's power supply 3. Remove the cover to the Base Station.

4. Locate JP103 and move the jumper to the Programming position.

2-27