Page 21

RF Setup

Frequency Bank (US only) Bank 0 Bank 1 Bank 2 Bank 3 Bank 4

0 1 2 3 4

• The default Frequency Bank is always 0. Don’t change this unless there are going to be more than 16 Base Stations operating in the same area. If you are using a RF Terminal that is the US version, you can select a different bank, expanding the number of possible frequencies to 80. • Setup to a Base Station is always done with Bank 0, regardless of the setting. Relays are not supported on any Bank other than 0. • Switching banks (to anything other than 0) is rarely needed. Additional banks were added to accommodate merchandise marts where many businesses are located under the same roof. This allows each business to operate on a separate frequency, maintaining privacy and avoiding interference from the other businesses also using RF Terminals. • This setting can be accessed only via the keypad Setup. RF Setup

Relay Existence No Relay Yes Search No Search Yes

0 1 2 3

• As shipped, the RF Terminal is not configured to work with Relays. If you want the Terminal to switch to a Relay as you walk out of range from the Base Station, set the Relay Existence to 1 (YES). • Relays will not work on any frequency bank other than 0. Relays are also not supported in One-Way Mode. • Site Testing will work with a Relay, but you must have only the Relay active (switching does not take place during Site Testing) - all other Relays and Base Stations must be off. We suggest setting Relay Existence to 0 (NO) before doing a Site Test. • If you want to search for the most powerful Relay each time your RF Terminal "signs on", use setting 3 (Search YES). Otherwise, the Terminal will always 2-8

Page 22

attempt to communicate with the last Relay or Base Station used. The Search option is useful when operators finish in one area, turn off the Terminal, and then move to another area to start again. RF Setup

Security Code Disabled Enabled

0 1

• A Security Code can be utilized to minimize the possibility of a Base Station listening to data from a Terminal that is talking to a different Base Station. A Security Code can also prevent interference from having many Base Station/RF Terminal configurations in one area; i.e. a merchandise mart with multiple vendors all running RF Terminal networks. • A Security Code consists of 3 characters - any combination of ASCII 33 ASCII 126. This allows for the possibility of more than 830,000 different character combinations. The characters are entered using the bar coded FULL ASCII MENU provided with the RF Terminal. See Appendix O; ASCII Code Equivalent Table for the correct corresponding characters. • Once you press 1 to enable the Security Code, you will see the following prompt on the Terminal: Enter Security Code_ You will be able to see the code as you enter it on the Terminal but once you have moved on to another Setup Parameter, you will only see the status; 0 (disabled) or 1 (enabled) if you go back to it. • If you forget the Security Code that you have already used on other Terminals, the only way to see the code is to go into the Base Setup. This requires that you have full access to the Base Station in order to change the programming jumper. See Chapter 2 for Base Station Setup. • You can only access the Security Code setup parameter by going into Setup Mode via the RF Terminal keypad but you must use the bar coded FULL ASCII MENU to scan in ASCII characters 33-126.

2-9

Page 23

Arrow Keys Only

Other

No Yes

0 1

• Some customers have requested that the Arrow Keys on the RF Terminal keypad be able to generate a response automatically, sending a separate message to the host by simply pressing the appropriate arrow key (without pressing the ENTER key afterward). This allows for simple and fast scrolling by the operator. The default setting is to require the ENTER key to be pressed before data transmission. • If you set this feature to 1 (YES), in order for the RF Terminal to transmit the following values, the corresponding Arrow Key must be the first key pressed in a data entry sequence. If it is not the first data entered, the arrow key is ignored. Arrow Key on RF Terminal

Code transmitted to Host

Up Arrow Down Arrow Left Arrow Right Arrow

FS (ASCII 28) GS (ASCII 29) RS (ASCII 30) US (ASCII 31)

The message is sent to the host as: Bytes

Function

Value

1 2 Last

RF Terminal ID Data Transmitted Terminator of Message

0-F FS, GS, RS or US CR

LCD Display Mode

Other

6 line display mode 4 line display mode

0 1

WARNING: All Terminals shipped with 6 line displays are configured as 6 line display terminals and will not work in an existing system setup for 4 line display terminals. If you are currently operating a system that uses 4 line displays and have not changed your program to utilize the 6 line display terminals, you MUST change the LCD Display Mode to 4 line display in order for a Terminal with a 6 line displays to SIGN ON to your system. • As of RF Terminal version 9075, support is included for both a 4 line and a 6 line display. Prior to version 9075, only 4 line display terminals were available. In order to maintain backwards compatibility, 6 line Terminals using version 9075 or greater have the ability to operate as either type of display. If you try to Sign-On with a terminal operating in 6 line mode to a Base with firmware prior to 9075, you will get the message: 2-10

Page 24

Base Reinitialized Cycle Power By default, the RF Terminal automatically determines which type of display is installed, and sets the LCD Display Mode accordingly. • The LCD Display Mode should only be changed if you are trying to integrate a new 6 line display terminal into an existing 4 line display system without having to change any of your programming. Our suggestion is to change your program to take advantage of the 6 line display. See the PROGRAMMING section for details.

LCD Backlight Display Mode (US only) No Yes

Other

0 1

Backlight Display is an optional feature that must be specified at time of order. The default setting is for the LCD Backlight to be OFF. Once you change the setting to 1 for YES, you need to set the Backlight Duration.

Backlight Duration (US Only) Always ON Duration in # of seconds

Other

0 1-9

The Backlight Duration is of no concern unless you have set the LCD Backlight Display to 1 for YES. This setting determines how long the Backlight Display is on at startup or when triggered by pressing the F2 key. Always ON will create a drain on your batteries and you can expect shorter battery life. Your best bet is to set a time between 1 and 9 seconds and turn it on when you need it by pressing the F2 key. RF Setup

Skip Opening Screens No Go to Two-Way (SIGN ON) Go to One-Way (ONE WAY)

0 1 2

• Many users want to skip the opening screens and go directly to SIGN ON or ONE WAY communication once their programs are fully operational. Selecting 1 or 2 will automatically take the operator to the corresponding mode and into your application, skipping the usual Mode Menu (SIGN ON?Y/N, SETUP?Y/N, ONE WAY?Y/N, SITE TESTING?Y/N). If you want to return to the Mode Menu at any time, simply press the F1 key. If your skip the opening screen, you may want to quickly check the settings 2-11

Page 25

of the Terminal without having to reset this parameter, so the Status Key will display four lines (starting with RFx9080) as follows: mm/dd/yy hh:mm alk - when Alkaline batteries are specified in Speaker/Battery setup rch- when NiMH or NiCad batteries specified in Speaker/Battery setup zz=percent or battery life left in numbers i.e. 99, 50, 23 Press the STATUS key again to resume processing. The next two lines show the following: TB9080A ID=0 Freq=0 RLY=N 6/6 SC=N C=N •

The first character on the line is: T for US/Canada Frequency E for European (includes UK) A for Australian G for old UK (458MHz) K for Korean

•

The next character “B” is the board level.

•

9080A is the firmware version

•

ID is the Terminal ID assigned (0-F)

•

Freq is the Terminal Frequency (0-F)

•

RLY=N indicates no relays (Y instead of N indicates Relays are to be sought)

•

6/6 is a 6 line terminal in 6 line mode; other possibilities are 6/4 and 4/4

•

SC=N indicates no Security Code is programmed (if Y, Security Code)

•

C=N indicates no Character mapping (if Y, beware, characters are remapped)

2-12

Page 26

RF Setup

Host Response Delay None Delay, in 1/10 second increments (.1 to 9.9 sec)

00 01 – 99

• Host Response Delay allows you to set a specific amount of time for a Terminal to wait before it attempts to retransmit data. By default, after a RF Terminal transmits its data to the host, it listens for a response from the host for 300ms. If the Terminal does not get a response or gets a "go to sleep" message during that time, it "wakes up" and re-transmits it's data according to the intervals specified below: Interval

Number of times repeated

½ second

5 times

2 seconds

1 time

4 seconds

1 time

8 seconds

1 time

16 seconds indefinitely - until prompt received

These “wake up” intervals are fine, especially if your host program processes it’s data quickly and gets a new data prompt out to the terminal sometime within the first set of ½ second interval. But if your host program is slow to respond, the continual re-transmissions outlined above generate a lot of unnecessary radio traffic. If your host program doesn’t process your data quickly enough to get a new prompt out to the terminal within a 1/2 second, Host Response Delay allows you to set a particular delay value that determines the first time the terminal will check with the Base for a new prompt. When you know your host program can't respond for 2 seconds, it doesn't make sense to check the host after ½ second and then every ½ sec for 5 times! This will significantly reduce the amount of radio traffic and conserve battery power. Reduced radio traffic also translates into more Terminals per Base and better response times in multi-Terminal networks. • Host Response Delay is particularly useful when multiple Terminals share a Base Station. By specifying the delay and eliminating wasted radio time, the actual average total response time will be less.

2-13

Page 27

Bar Codes

Code 3 of 9 (Code 39) Enable Code 3 of 9 Disable Code 3 of 9 Enable Full ASCII Code 39 Disable Full ASCII Code 39 Enable Code 39 Accumulate Mode Disable Code 39 Accumulate Mode Enable Start/Stop character transmission Disable Start/Stop character transmission Enable Mod 43 Check Digit Disable Mod43 Check Digit Enable Check Digit transmission Disable Check Digit transmission Caps Lock ON Caps Lock OFF

0 1 2 3 4 5 6 7 8 9 A B C D

•

The Start and Stop character for Code 39 is the * character. Settings 6 and 7 determine whether or not those characters are transmitted to the computer along with the data. For example, at setting 6, the data of 1234 would be transmitted as *1234*. Transmitting the start and stop characters can be useful if you need to differentiate between data that comes from a bar code versus data coming from the keypad.

•

Enabling use of the Mod 43 check character requires that the last character of your bar code conform to the Mod 43 check character specifications. See Appendix E; Code 39 for more information. Enable transmission (A) will send the check digit data along with the rest of the bar code data to your computer. To use A, you must also be using 8.

•

Caps Lock ON causes lower case letters read as data to be transmitted to the computer as UPPER CASE, and upper case letters to be transmitted as LOWER CASE. Numbers, punctuation and control characters are not affected. Caps Lock OFF means that letters will be transmitted exactly as read. This setting applies to all bar code types.

•

See Appendix E; Code 39 for more information regarding Accumulate Mode.

2-14

Page 28

Bar Codes

UPC/EAN Enable UPC/EAN Disable UPC/EAN Enable UPC/EAN Supplements Disable UPC/EAN Supplements Enable transmission of UPC-A NSC or EAN 13 1st 2 digits Disable transmission of UPC-A NSC or EAN-13 1st 2 digits Enable transmission of UPC-A and EAN-13 check digit Disable transmission of UPC-A and EAN-13 check digit Enable transmission of UPC-E NSC and EAN-8 1st digit Disable transmission of UPC-E and EAN-8 1st digit Enable transmission of UPC-E and EAN-8 Check digit Disable transmission of UPC-E and EAN-8 check digit UPC-E0 Compressed UPC-E0 Expanded EAN-8 observing 9&A EAN-8 forced to transmit 8 digits always

0 1 2 3 4 5 6 7 8 9 A B C D E F

• Use setting 2 to enable reading of the 2 and 5 digit UPC/EAN supplements commonly found on magazines and paperback books as well as the Extended Coupon Codes. Using this setting force left to right reading of UPC codes to assure that the supplement code is not missed. • ISBN (International Standard Book Numbering) bar codes are EAN-13 with a 5 digit supplement. If the “Bookland” bar code uses 978 (books) or 977 (periodicals) as the first three digits, then the RF Terminal can transmit it in the ISBN format. The settings for this are found under the Laser Options parameter. To enable transmission of the ISBN format, set the Laser Options parameter to D. To return to the default of normal EAN-13 transmission, set it to C. For details on ISBN, see Appendix J; UPC/EAN. • Use setting 4 and 9 to enable transmission of the NSC character to your computer. The Number System Character is the leading character in the bar code. For details, see Appendix J, UPC/EAN. • Use setting 6 and A to enable transmission of the check digit character to your computer. The check digit is the last character and is based upon a calculation performed on the other characters. • Setting C transmits UPC-E0 bar codes as is; setting D transmits them with inserted zero’s to make them the same length as a UPC-A bar code. A NSC of 0 is assumed. It is possible to read UPC-E1 bar codes; by default this option is disabled. Do not enable UPC-E1 if you plan on reading EAN-13 bar codes; you may experience partial reads when reading EAN-13. The UPC-E1 option is set in the 2 of 5 Code parameter. To enable UPC-E1 reading, set the 2 of 5 Code parameter to 8. To turn off UPC-E1 reading, set it back to the default of 9. 2-15

Page 29

• If you prefer to transmit UPC-E bar codes in a 6-digit format while EAN-8 is transmitted in its original 8-digit format use setting F. This will allow you to use settings 9 and A and still transmit EAN-8 as 8 digits. • UPC-A can be transmitted in EAN-13 format by adding a leading 0 (USA county code) to the UPC-A data. This setting is found in the Laser Options parameter. To transmit in EAN-13 format, set the Laser Options parameter to F. To return to the default (UPC-A transmitted in original format) set it to E. Bar Codes

Code 128 Disable Code 128 Enable Code 128 Enable UCC/EAN-128 Disable UCC/EAN-128 Enable Storage Tek Tape Label Code Disable Storage Tek Tape Label Code Bar Code ID’s transmitted Bar Code ID’s not transmitted

0 1 2 3 C D E F

• UCC/EAN-128 is a subset of Code 128 that follows certain specifications regarding character content, length and check digits. Enabling UCC/EAN128 (2) causes the RF Terminal to look for a Code 128 bar code that begins with the Code 128 F1 (Function 1) character. See Appendix H: Code 128 for more details. • The StorageTek Tape Label code is a proprietary variation of Code 39 code used for the storage of computer data tapes. Enabling the tape label code (C) does not disable reading of Code 128 or Code 39 bar codes. • Bar Code ID’s are characters assigned to each bar code type to identify that particular type of code. These Bar Code ID’s can be used to identify what type of bar code you are using when you are not sure or you want your application to differentiate between the different types. The Bar Code ID’s are assigned as follows: Bar Code

ID

Bar Code

ID

Bar Code

ID

Bar Code

ID

Codabar Code 39 UPC-A EAN-13 a b c d

I 2of5 2 of 5 Code 128 Code 93 e f g i

MSI UPC-E(0) UPC-E (1) EAN-8 j n o p

StorageTek Plessey LabelCode 4 LabelCode 5 s x y z

The ID character is transmitted in front of the bar code data.

2-16

Page 30

Bar Codes

Codabar Enable Codabar Disable Codabar Enable CLSI Codabar Disable CLSI Codabar Disable Start/Stop character transmission Enable Start/Stop character transmission

0 1 2 3 4 5

• CLSI is a form of Codabar often used by libraries. • Setting 5 will transmit the Codabar start and stop characters with the bar code data to your computer. If you are varying the start and stop characters to differentiate between different labels, transmitting the start and stop can be helpful. See Appendix G; Codabar for more information. Bar Codes

2 of 5 Code Enable Interleaved 2 of 5 Disable Interleaved 2 of 5 Enable Interleaved 2 of 5 check digit Disable Interleaved 2 of 5 check digit Enable check digit transmission Disable check digit transmission Enable Standard 2 of 5 Disable Standard 2 of 5 Enable UPC- E1 Disable UPC- E1 Normal decode algorithm (Laser scanners) Loose decode (Symbol LS2000 laser only) Looser decode (Symbol LS2000 laser only)

0 1 2 3 4 5 6 7 8 9 B C D

• Setting 2 requires that the last digit in your bar code conform to the specifications for the 2 of 5 check digit calculation. See Appendix I; 2 of 5 Code for more information. • Transmission of the check digit (5) requires the use of setting 2 and will transmit the check digit along with the bar code data to the computer. • Setting B pertains to the decoding algorithms used by the RF Terminal when using a Laser Scanner. In most cases, this should be left at the default B setting. • If scanning through windshields with a laser scanner, (the Symbol LS2000 is the best performer) try setting this parameter to C or D. Try C first, if you still don't have satisfactory results, try D.

2-17