Browse
(440) 299-7778
Menu
(440) 299-7778
One-year parts and labor warranty30-day money-back guaranteeEnglishEspañolContact

The text of a manual · part 2 of 19

Worth Data R/F Terminal Owner's Guide, pages 11 to 20

Pages 11 to 20 of 180

The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Worth TriCoder LT71

Page 11

the terminal is capable of supporting the Zebra Cameo and Encore portable printers. To move on to the first menu item, press any key on the R/F Terminal keypad. The display now reads: SIGN ON? KEY [YES/NO]?_ • Press the YES key to SIGN ON to a two-way communication host computer program through the Base station. • Press NO to move on to the next menu item: SETUP MODE? KEY [YES/NO]?_ • Pressing YES prompts for a password to enter the Setup Mode for the R/F Terminal or Base station. • Press NO to move on to: ONE-WAY? KEY [YES/NO]?_ • Press YES to enter ONE-WAY mode. ONE-WAY mode allows the R/F Terminal to transmit data to the host computer without prompting from the host computer program – we call this “dumb” data entry. ONE-WAY mode is also useful for demos, as it does not require any interaction from the host computer. • Press NO to go to: SITE TESTING? KEY [YES/NO]?_ • Press YES to enter SITE TESTING. SITE TESTING is an excellent way to assess your R/F communication in any area. It can help you determine the best place to locate your Base station for maximum R/F performance as well as troubleshoot problems that may relate to range or interference. • Press NO to loop back to the SIGN ON? prompt. You can back-out of any mode or prompt by pressing the F1 key. For example, if you press YES at the SETUP MODE? prompt but really meant to press NO, press the F1 key to take you back to the menu. The F1 key on the R/F Terminal keypad works like the ESC key on the PC – it will usually get you out and back to the previous step. You can use the F1 key to exit and SIGN OUT when using a Two-Way communication program running on the host computer. 1-8

Page 12

The entire mode menu can be skipped (see Chapter 2; RF System Setup), causing the R/F Terminal to automatically SIGN-ON or go to ONE-WAY mode on power up.

Installing the R/F Terminal Utilities Software The R/F Terminal system ships with a CDROM of programs for use with the R/F Terminal and Base station. The CDROM contains programs for the TriCoder and the RF Terminal. Click on the RF Terminal button. Next you have the choice of installing the following:

Windows Demo Programs and RF DLL Programmers Library Demo Programs in VB, Access, and Delphi 16 bit and 32 bit DLLs VB DLL-based Encore printer demo program

ActiveX Tools Serial Interface (includes Excel and VB demos) TCP/IP (includes VB/Access and Delphi demos)

Windows RF Terminal Firmware Loader Program DOS/BASIC source demo programs (requires GWBasic or QBasic) Click on the set of programs you wish to install. To install any of the programs found on the Utilities CD, simply insert the CD into your CDROM drive. The install program should start automatically. If it does not, simply run the SETUP.EXE program found on the CD.

Running the demo programs… The demo programs are all programs provided to help you test your R/F Terminal with a two-way communication program.

Using the Windows Terminal Loader Utility The R/F Terminal Loader program is a Windows application that allows you to download new R/F Terminal firmware from Worth Data into your R/F Terminal. New firmware can be obtained on diskette directly from Worth Data or downloaded via the Web at: http://www.barcodehq.com/download.html

1-9

Page 13

Installing the Windows Terminal Loader Utility This program is for Windows 95, 98, NT, 2000, ME and XP : 1. Insert the CDROM into your CD drive. The "Hardware Utilities Installation" program should start automatically. If it does not, double click on the SETUP.EXE program on the CD in Windows Explorer. 2. Click on the RF Terminal button to select the type of hardware. 3. Click on the "Install RF Loader" button. 4. Follow the installation instructions on the screen. Setup installs three programs and creates a program group for them: R/F TERMINAL EPROM LOADER HELP R/F TERMINAL EPROM LOADER UNINSTALL See Appendix D; Firmware Upgrades for details on how to use the EPROM Loader programs (Windows).

1-10

Page 14

Chapter 2

RF System Setup RF Terminal Setup The RF Terminal itself can be configured using the Terminal keypad or by using the bar coded Setup Menu. Even if you configure the RF Terminal using the keypad, you may need the bar coded Setup Menu to use as a reference. Most users do not need to change anything in the setup. The most commonly changed setup parameters are the Terminal ID (especially if you have more than 1 terminal) and the Frequency (if you are adding an additional Base station). Some parameters are available only by bar code menu and others only by keypad: Bar Code Menu Only Characters Reset

Keypad Only Security Code Frequency Bank Host Response Delay Relay Existence Arrow Keys Only Skip Opening Screens Display of Year LCD Display Mode LCD Backlight Display

If you are using the bar coded Setup Menu and are unfamiliar with scanning bar codes, see Appendix M; How to scan a bar code to learn proper scanning technique before you begin scanning the bar codes on the Setup Menu.

RF Terminal Default Settings This is the default configuration of the RF Terminal as it is shipped from the factory. If you ever need to return the RF Terminal to these default settings, use the bar coded Setup Menu and scan the following bar codes in this sequence: • START SETUP • RESET • END SETUP

2-1

Page 15

Default RF Terminal Configuration Parameter

Default Setting

Parameter

Default Setting

Radio Terminal ID

0

MSI Code

Disabled

RF Frequency

0

Relay Exist?

No

Plessey Code disabled

Code 39

Enabled

Label Code5 disabled

Accumulate Mode ON check digit not transmitted

Code 93 stop/start chs not xmit check digit disabled

Date Format

Caps lock OFF 2 of 5 Code

Disabled

Beep Tone medium

I 2 of 5 Code disabled

Speaker Operations

Speaker on Alkaline batteries used check digit disabled

Preamble none

Enabled

Postamble none

UPC supps disabled

Baud Rate

9600

UPC-A NSC & check digit transmitted

Parity none

Data Bits

8

EAN-13 country code & check digit transmitted

Stop Bits

1

Security Code none

UPC-E 1st char & check digit not transmitted

Frequency Bank

0

Laser Options none

EAN-8 1st char & check digit not transmitted Codabar mm-dd-yy (if US version) dd-mm-yy (if other)

6 digit code length

UPC/ EAN

Disabled Full ASCII disabled

Shut Down Time

5 minutes

Voice Messages

303015

Disabled

Arrow Keys Only no

Start/Stop not transmitted

Characters none reassigned

CLSI format disabled

Host Response Delay none

Code 11

Disabled

Display of year

2 digit

Code 128

Disabled

Skip opening screens no

EAN/UCC 128 disabled

LCD Display Mode

0

LCD Backlight Display

0

*All parameters are set back to their defaults when reset using the bar coded Setup Menu, even parameters that are changed by keypad only. Shaded items are keypad access only.

Using the bar code RF Terminal Setup Menu To use the bar coded RF Terminal Setup Menu, scan these bar codes in this order: • • • •

Start Setup - you should hear 2 beeps Setup Parameter bar code (i.e. “Beep Tone”)-you should hear 2 beeps for each scan Number bar code that corresponds to the appropriate setting (i.e. “3” to change the Beep Tone to “high”) - you should hear 2 beeps for each scan End Setup-you should hear 3 beeps after END SETUP.

More than one Setup Parameter can be changed before you scan END SETUP. For example, if you scanned START SETUP, then “Beep Tone”, then 3, then “Speaker Operation”, then 1, then END SETUP, this would change the beep tone to “high”, and turn the speaker "off".

2-2

Page 16

If you are using a Laser Scanner to setup the RF Terminal, the beam will often cover more than one bar code. Cover any adjacent bar codes before scanning, and then check the RF Terminal display to make sure the correct setting was entered.

Using the keypad to setup the RF Terminal The RF Terminal can be setup via the Terminals' keypad by entering Setup Mode from the menu. Turn on the Terminal and press any key. You should see the SIGN ON? message: SIGN ON? KEY [YES/NO]?_ Press the NO key. The next prompt is the SETUP MODE? prompt: SETUP MODE? KEY [YES/NO]?_ Press the YES key. At this point, the terminal will ask for a password: SETUP MODE PASSWORD?_ Enter WDTRI on the keypad. The next item allows you to choose which item to configure: R/F Terminal------->1 R/F Base Setup--->2 Voice Operations->3 Press 1 to enter the RF Terminal Setup. Now you are in the RF Terminal Setup Menu and can choose from the following options: RF Setup---0 BarCodes--1 RS232-------2 Date/Time--3

Speaker--4 Other------5 Exit-------F1

At this point, choose which group you want to configure. Most of the RF Terminal setup parameters are accessible from the keypad Setup Menu (there are only 2 that are available only from the bar code Setup Menu). Reversely, there are quite a few options that are available only from the keypad Setup. See the beginning of this chapter for a comparison of the two Setup Menus.

2-3

Page 17

The groups in the keypad Setup Menu contain the following setup parameters: Setup Group

Parameter

Setup Group

Parameter

RF Setup 0

RF Terminal ID

RS232 2

Baud Rate

Bar Codes 1

RF Frequency Relay Existence Security Code Frequency Bank Skip opening screens Host Response Delay

Date/Time 3

Code 3 of 9 UPC/EAN Code 2 of 5/I 2 of 5 2 of 5 Length Code 128 Codabar MSI/ Plessey Code 11 Code 93

Protocol Parity Data Bits Stop Bits Set Time Set Date Date Format Display of Year

Speaker 4 Other 5

Speaker/Batteries Beep Tone Shut Down Time Preamble Postamble Voice Messages Laser Options Arrow Keys Only LCD Display Mode LCD Backlight LCD Backlight Duration Arrow Keys Only

Once you have selected a group to edit, you will see each parameter displayed in the order listed above. Use the next section of this chapter as a reference for all RF Terminal Setup Parameters, whether they are configured using the keypad or the bar coded Setup Menu. Each parameter is followed by either a key symbol: and the group you will find the parameter in,

RF Setup or a bar code symbol:

or both, depending on how the parameter can be configured.

2-4

Page 18

RF Terminal Setup Parameters Default settings are shown in bold type in this manual and are marked by a * on the bar code Setup Menu. The RF Terminal will typically require no setup changes except, Terminal ID (if more than one terminal) and enabling bar codes to be read other than UPC or Code 39. RF Setup

RF Terminal ID Default ID Available ID's

0 0-9, A-F

• The default Terminal ID is always shipped as 0. If you have more than one RF Terminal assigned to a Base Station, you must be sure that each RF Terminal has a unique Terminal ID, (otherwise you will have big troubles including false error messages). The Terminal ID is always displayed on the Start Up screen when you power up the terminal. There are sixteen Terminal ID's available - the numbers 0-9 and the letters A-F. To change the Terminal ID, enter one character either by scanning from the bar code Setup Menu or by pressing a key on the RF Terminal keypad. The frequency setting is displayed on the RF Terminal’s opening screen. RF Setup

RF Terminal Frequency Default Frequency

0

• The default Frequency is always shipped as 0. There are 16 frequencies on Bank 0 that will accommodate just about everyone. By switching frequency banks, there are 80 frequencies available, but they are rarely used. The Frequency can be set to any of the 16 frequencies on any bank by entering the corresponding character (0-9, A-F) either by scanning the bar coded Setup Menu or by entering the character from the RF Terminal keypad. • All Terminals, Base Stations and Relays in the same system must be set to the same frequency. The frequency is always displayed on the Start Up screen when you power up the Terminal. If you are using Relays, you are restricted to Bank 0 only. Site tests and Base Programming always take place on Bank 0. • There are different frequencies available depending upon the country you are operating in. Each country has a different EPROM version and will display the version on power-up. These are the frequencies available for each country:

2-5

Page 19

USA / Canada / Mexico There are 80 frequencies available for the US, Canada and Mexico. These frequencies display as "USA Frequency" on the screen upon power-up of the Terminal. The frequencies in MHz are: Freq.

Bank 0

Bank 1

Bank 2

Bank 3

Bank 4

0 1 2 3 4 5 6 7 8 9 A B C D E F

911.75 912.15 912.55 912.95 913.35 913.75 914.15 914.55 914.95 915.35 915.75 916.15 916.55 916.95 917.35 917.75

902.35 902.75 903.15 903.55 903.95 904.35 904.75 905.15 905.55 905.95 906.35 906.75 907.15 907.55 907.95 908.35

908.75 909.15 909.55 909.95 910.35 910.75 911.15 911.55 911.95 912.35 912.75 913.15 913.55 913.95 914.35 914.75

915.15 915.55 915.95 916.35 916.75 917.15 917.55 917.95 918.35 918.75 919.15 919.55 919.95 920.35 920.75 921.15

921.55 921.95 922.35 922.75 923.15 923.55 923.95 924.35 924.75 925.15 925.55 925.95 926.35 926.75 927.15 927.55

Versions

RF Terminal Base Station Relay Station

RFT9.nnn DLC9.nnn RLY9.nnn

Australia / New Zealand There are 16 frequencies available for Australia and New Zealand. These frequencies are displayed as "AUZ Frequency" on the screen at power-up of the Terminal. The frequencies in MHz are: Freq

MHz

Versions

0

MHz

921.50

Freq

8

924.70

RF Terminal

RFA9.nnn

1

921.90

9

925.10

Base Station

DLA9.nnn

2

922.30

A

925.50

Relay Station

RLA9.nnn

3 4 5 6 7

922.70 923.10 923.50 923.90 924.30

B C D E F

925.90 926.30 926.70 927.10 927.50

2-6

Page 20

Europe There are only 9 frequencies available for Europe (UK, Germany, Austria, Switzerland, The Netherlands, Spain, Ireland, Portugal, and Italy). These versions display as "EUR Frequency" on the screen at power-up of the Terminal. The frequencies in MHz are: Freq

MHz

Versions

0

MHz

433.575

Freq

5

433.825

RF Terminal

RFE9.nnn

1

433.625

6

433.875

Base Station

DLE9.nnn

2

433.675

7

433.925

Relay Station

RLE9.nnn

3 4

433.725 433.775

8

433.975

Korea There are only 10 frequencies available for the Korean versions. These versions display as "KOR Frequency" on the screen at power-up of the Terminal. The frequencies in MHz are: Freq

MHz

Freq

MHz

0

424.725

6

424.875

Versions

RF Terminal

RFK9.nnn

1

424.750

7

424.900

Base Station

DLK9.nnn

2

424.775

8

424.925

Relay Station

RLK9.nnn

3 4 5

424.800 424.825 424.850

9

424.950

2-7