The text of a manual · part 1 of 19

Worth Data R/F Terminal Owner's Guide, pages 1 to 10

Pages 1 to 10 of 180

The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Worth TriCoder LT71

Page 1

Worth Data R/F Terminal Owner’s Guide 10/03

Page 2

Table of Contents Chapter 1 Installation ..................................................................... 1-1 Components ....................................................................1-1 Installation Summary ......................................................1-2 Connecting the Base Station to a serial port.........................1-2 R/F Terminal Operation .......................................................1-4 Battery Functions ............................................................1-4 R/F Terminal Menu Functions ........................................1-7 Installing the R/F Terminal Utilities Software .....................1-9 Chapter 2 RF System Setup .......................................................... 2-1 RF Terminal Setup ...............................................................2-1 RF Terminal Default Settings .........................................2-1 Using the bar code RF Terminal Setup Menu .............2-2 Using the keypad to setup the RF Terminal ................2-3 RF Terminal Setup Parameters.............................................2-5 Base Station Setup..............................................................2-27 Base Station Setup Parameters ...........................................2-29 Chapter 3 Operational Theory....................................................... 3-1 How the Two-Way RF System works ..................................3-1 How the One-Way RF System works...................................3-4 How Site Testing works .......................................................3-5 Chapter 4 Performance Issues...................................................... 4-1 Evaluating your area of planned operation...........................4-1 Performing a Site Test ..........................................................4-2 Relay Stations.......................................................................4-4 Dealing with radio traffic contention....................................4-7 Chapter 5 Before you begin programming… .............................. 5-1 Failure Planning ...................................................................5-2 Chapter 6 Programming for the RF Terminal .............................. 6-1 Low Level ASCII sequences ................................................6-1 Low Level ASCII sequences with Windows DLL .............6-12 PromptCOM ActiveX Controls ..........................................6-12 TCP/IP ActiveX Controls...................................................6-21 Chapter 7 Voice Message Operations .......................................... 7-1 Why Use Voice Messages and Prompts? .............................7-1 RF Terminal’s Voice Message Mapping..............................7-2 Programming Voice Messages .............................................7-3 Chapter 8 Troubleshooting ........................................................... 8-1 10/03

Page 3

Appendices A Frequency and Jumper Changes ...............................A-1 B

Adding Relays ..............................................................B-1

C R/F Serial Pin-outs .......................................................C-1 D Firmware Upgrades......................................................D-1 E Code 39 Specifications ................................................ E-1 F Code 93 Specifications ................................................ F-1 G Codabar Specifications ...............................................G-1 H Code 128 Specifications..............................................H-1 I

Interleaved 2 of 5 Code Specifications ....................... I-1

J

UPC / EAN Specifications............................................ J-1

K MSI/Plessey Specifications .........................................K-1 L

Piggyback Laser Installation....................................... L-1

M How to scan a bar code .............................................. M-1 N Using the Scan Stand ..................................................N-1 O Optional Features.........................................................O-1 P

ASCII Code Equivalent Table ...................................... P-1 Index ..................................................................................1

Page 4

Chapter 1

Installation Components The components in your R/F Terminal system will vary according to the configuration of your system. Your R/F Terminal shipment should contain at least: • An R/F Terminal T7x or LT7x (unit includes keypad and display). If the R/F Terminal is an LT7x model, it will have an integrated laser scanner built-in to the body of the terminal. • An optional Scanner – Laser, Wand or CCD that plugs into the scanner port of the R/F Terminal. You have a built-in laser scanner if you ordered the LT7x model. (LT means Laser Terminal) • A Shoulder Strap and Rubber Boot – which if used, will minimize the damage from accidental drops in usage. (The shoulder strap has to be installed with a screw driver per the included instructions) • A R/F Terminal Setup Menu- this is an 8.5” x 11” laminated sheet consisting of bar codes used to configure the R/F Terminal. • Utilities CD ROM – demo programs, DLL, and firmware loader program! If Base Stations or Relay Stations were ordered with your system, you should receive at least: • A Base Station (B5x) and/or Relay Station (R5x) including a 5v power adapter for each. • A Serial Cable (F34 or F36) if a Base Station. • RS422 Y Cables (F44) if using multiple Relay Stations. • A Test Relay Cable – if a Relay was ordered. This is a short cable just for testing. Relay cables are much longer and are supplied by the user, (use CAT 5 or Belden 1227A1 wire.) Keep the shipping box for the R/F Terminal in the event it is necessary to return equipment for repair later.

1-1

Page 5

Installation Sequence 1. Start with one Terminal and Base Station. Get everything working with the single terminal and base and then add other terminals, being certain that all terminals have unique Terminal IDs. After all terminals are working, add the first relay, remembering to change each terminal’s setup to Relay=Yes before testing. Then add remaining relays, remembering to: 1) assign Relay IDs, and 2) set the jumpers of each relay to terminated or not terminated properly. 2. All equipment is shipped with the default setting of Frequency 0. Unless you have other Terminal/Base configurations already operating on that frequency, you probably don’t need to change the frequency. 3. Remember, Relays and Bases are not the same product. They look the same, but they have different firmware, attach differently, different jumper settings, and different product labels. Relays and Bases can be converted in the field with new firmware EPROM and jumper changes. (Base Stations and relays require a 5v power supply from Worth Data. If you use a different power supply, it will probably burn up the Base or Relay Station.) 4. Without attaching the Base Station to the computer, and with only the power supply plugged in the base, you can perform a site test to be sure you have adequate coverage and the radios are working perfectly. (See Chapter 4). 5. Now connect the Base Station to the computer’s serial port. Be sure to turn OFF all handshaking on the COM port used; in Windows, go to Start Menu, Settings, System, Device Manager, Ports (COM and LPT). Now run one of the RF Terminal demo programs found on the Utilities CDROM. 6. Now run one of the demo programs to validate that everything is working. If you have problems, refer to the Trouble Shooting Section.

Connecting the Base Station to a serial port How it works… The R/F Terminal transmits data to the Base station, which in turn transmits the data to the host serial port. The computer software reads the data coming through the serial port and processes the information accordingly. When the computer software running on the host has a task for the terminal, it transmits data out to the serial port, which then passes this data on to the Base station. 1-2

Page 6

The Base station then broadcasts the message to the terminal, causing the terminal to display the message to the user. The Base station is not machine-sensitive (it needs a standard RS-232 serial port) nor is it operating system dependent (you just need to be able to read and write to the serial port as a separate device).

Connecting the Base station… If you specified a 25 pin cable (part #F34) or a 9 pin cable (part #F36) when you ordered your Base station, simply plug the RJ45 end of that cable into the COMPUTER port on the Base station, and the 25 or 9 pin end into your computer’s serial port. If you are not connecting to a PC, see Appendix C for cable and serial pin-outs. If your extension cable is over 80 feet long and you are running Windows, open up the DB9 or DB25 connector on the base station side and cut the unused pins (see Appendix C.). For an extension cable, you can use existing network cabling already in existence, but you must be certain that the Transmit and Receive data lines are not in the same twisted pair. If you are using an extension cable and are having problems, test the cable by: 1. Connecting the Base station without using the extension cable. Simply plug in the F34 or F36 cable that came with the Base. 2. If the Base works with only the F34 or F36 cable in place, add in the extension cable without changing the physical location of the Base station. If the extension cable appears to be the culprit, check to be sure that Transmit lines are connected to Receive lines.

Configuring the Base station… After connecting the Base station to your serial port, you need to configure the serial settings on the Base station to match those required by your software. We recommend using the default settings when at all possible. The default settings are: • • • • •

9600 baud No parity 8 data bits 1 stop bit “None” protocol setting

If you have to change any or all of these settings, see Chapter 2 for details on configuring the Base station using the R/F Terminal keypad.

1-3

Page 7

Base station frequency… To determine what frequency your Base station is set to, plug in the power supply and watch the LED light on the front of the Base station. The LED will blink “the frequency + 3” times. For example, the default frequency is 0. On power up, the LED on a Base station set to frequency 0 would blink 3 times. A Base station set to frequency 5 would blink 8 times. If this is the only Base station operating, leave the frequency at 0. If you have other Base stations in the area and need to change the frequency, see Appendix A; Frequency and Jumper Changes for details on how to open the Base station and set the rotary switch inside to the desired frequency.

R/F Terminal Operation Using the RF Terminal keypad… The R/F Terminal is turned on by pressing the green ON/OFF button located in the upper left-hand corner of the R/F Terminal keypad. The R/F Terminal has a Shut Down Time feature that allows you to determine the length of time the R/F Terminal must be inactive before automatically shutting down to conserve battery power. When the R/F Terminal shuts down, simply press the ON/OFF button to resume operation. The keypad is custom designed for the R/F Terminal operations. It has numeric and control keys in the non-shifted state, and alpha characters in its shifted state. You can readily determine if the SHIFT is on by the cursor on the display. When SHIFT is on, the cursor is a large black rectangle. When SHIFT is off, the cursor is a narrow underline character. For all prompts which ask for a YES or NO response, the ENTER key, is the YES reply, and the -(minus) key is the NO reply. As you key data, you will see each character displayed on the screen. If you make a mistake, you can delete the last character by pressing the DELETE key, or you can clear all characters displayed on the screen by pressing the CLEAR key.

Battery Functions Three AA batteries provide the main power for the scanner, display and electrical circuitry. Either alkaline (including Alkaline rechargeables), Nickel Metal Hydride rechargeable batteries or NiCad rechargeables may be used, (Nickel Metal Hydride, NiMH, batteries are preferred). If you decide to use NiCad or NiMH batteries, be sure change the Terminals Setup in Speaker/Batteries to rechargeable batteries; otherwise, the terminal will not know when to shut down without causing problem. NiCad and NiMH batteries don’t have the same level of reserve power as alkalines, so the Terminal will 1-4

Page 8

attempt to continue operation beyond the capability of the batteries if the Setup is left at the default alkaline setting. Alkaline batteries (including alkaline rechargeables) should provide approximately 14 hours of continuous operation with 8 transactions per minute average. NiCad rechargeable batteries will give approximately 40% less operational time than alkalines.

Rechargeable Batteries If you want to use rechargeable batteries, you can use a fast external 3rd party charger, you can use slower trickle recharging circuitry that allows you to recharge the batteries while installed in the R/F Terminal. To use the recharging circuitry on the T71/LT71 terminals, you must change a jumper inside the R/F Terminal itself, (see Appendix A, Hardware Changes on the RF Terminal). Recharging circuitry is standard on the European terminals – there are no jumper changes required. To recharge batteries in a RF Terminal, simply plug in an optional additional charge Worth Data 5v Power Adapter. For best results, use only NiMH rechargeable batteries. NiMH Rechargeable Batteries are available from Worth Data and can be ordered as part number L01 for $10.00 for a set of 3. The internal trickle charge takes 8-10 hours. Inexpensive, external chargers can be purchased which recharge batteries in 2-3 hours. You can safely use alkaline batteries in a terminal set for recharging, providing you don’t plug a power supply into the terminal. Recharging Alkaline batteries may cause the batteries to explode and leak battery acid throughout the RF Terminal. Battery acid damage is not covered by the Worth Data warranty because it not deemed to be “normal use”. IMPORTANT! If you decide to use NiMH or NiCad batteries, with the internal charging or an external charger, be sure to change the Speaker/Battery setting to “rechargeable” or your terminal will start exhibiting very strange behavior as the batteries run down. If you are using alkaline batteries (either regular or rechargeables) and have selected the NiCad/Rechargeables setting in the Speaker/Battery setup parameter (See Chapter 2; RF System Setup), the RF Terminal will generate the following error message: Warning Alkaline Batteries Detected Nicads Are Specified Do Not Recharge

1-5

Page 9

Battery Life Indicator The R/F Terminal detects low AA batteries and displays the following message: LOW BATTERIES Finish, Sign Off Change Batteries Hit Any Key_ At this point you have approximately 2 minutes of operational time to finish your transaction (or note where you are leaving off if in the middle of a transaction) and sign off. After 2 minutes, the R/F Terminal will display: CHANGE BATTERIES UNIT SHUT DOWN_ This message will display for 20 seconds before the R/F Terminal signs off from the host (if signed on) and then shuts itself down. If you turn it back on without changing batteries, you may experience constant beeping, intermittent scanning, and very irritating symptoms that look like equipment failure. Once you remove the batteries, you have 5 minutes to change them before you lose the date and time in the Real-Time Clock. The R/F Terminal also has a battery life indicator that can be accessed while operating in ONE-WAY or TWO-WAY mode or while in the MENU. To display the remaining battery life of the AA batteries (as well as the date and time) press the STATUS key: mm/dd/yy hh:mm x=a when Alkaline batteries are specified in Speaker/Battery setup x=n when NiMH or NiCad batteries specified in Speaker/Battery setup zz=percent in numbers i.e. 99, 10, 05 Press the STATUS key again to resume processing.

To change the AA batteries: 1. Turn OFF the R/F Terminal. 2. Remove the battery holder door on the back of the R/F Terminal by pressing down on the grooved portion of the door and pushing outward. 3. Remove the old batteries and insert the new ones, making sure to orient the batteries according to the diagram inside the battery holder. The positive (+) end of the battery should be facing down toward the bottom of the R/F Terminal.

1-6

Page 10

4.

If using rechargeable batteries, make sure that rechargeables are specified. See the previous page to quickly determine the setting using the Status key.

5. Replace the battery door and turn the reader on using the ON/OFF switch. 6. Sign ON and resume your application.

R/F Terminal Menu Functions There are four modes of operation for the R/F Terminal: SIGN ON

Signs R/F Terminal on for two-way communication with host.

SETUP MODE

Accesses Setup parameters for Terminal and Base.

ONE-WAY

Allows “dumb” data entry to computer. No prompts from host computer

SITE TESTING

Allows user to test range and evaluate site to determine best position for Base. Also the acid test for suspected radio failure.

Upon power-up, the R/F Terminal displays the following opening screen: R/F TERMINAL S9nnn TERM ID: 0 6/6 XXX FREQUENCY: 0 Z HIT ANY KEY (The opening screen can be bypassed upon power up. See Chapter 2 for details) • The first line on the screen, R/F TERMINAL S9nnn, gives the firmware revision number. • TERM ID: 0 refers to the current Terminal ID. The default setting is 0. If operating in a multi-R/F Terminal system, each Terminal must have a unique ID. The second part of this line identifies the display lines. Possibilities are 4/4 (4 line terminal operating in 4 line mode), 6/4 (6 line terminal operating in 4 line mode, and 6/6 (6 line terminal operating in 6 line mode). • Line 3 refers to the frequency currently used by the R/F Terminal. XXX FREQUENCY: 0 refers to a Terminal set to frequency 0. XXX corresponds to the country the frequency corresponds to. A Terminal using the USA /Canada/Mexico frequencies would read USA FREQUENCY:0. If a Z also appears on this line to the right, 1-7