The text of a manual · part 6 of 19
Worth Data R/F Terminal Owner's Guide, pages 51 to 60
Pages 51 to 60 of 180
The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Worth TriCoder LT71
Page 51
you are entering data from the RF Terminal keypad, you must press the ENTER key to transmit your data. If the Base Station receives the data, the RF Terminal displays the following prompt: Data Received Was aaaaaaaaaaaaaaaaaa Enter Data? Where aaaaaaaaaaaaaaaaaa is the data received by the Base Station (and transmitted to the Host Computer if connected). You can exit One-Way Mode simply by pressing the F1 key on the RF Terminal keypad. In One-Way Mode, the RF Terminal transmits its Terminal ID to the Base Station but it does not pass it on to the Host Computer. If your application on the Host Computer needs to know which RF Terminal data came from, use the Preamble setup parameter to enter unique identifying information. Data is also transmitted without a Terminator Character (like a CR or TAB that is transmitted after the data); so if you need one, use the Postamble setup parameter to add the appropriate character(s) after your data. For more information on Preambles and Postambles see Chapter 2; RF System Setup for details.
How Site Testing works The RF Terminal uses Site Test mode to: 1) test the radios at short range, (30 ft.) as an acid test for correct operation, and 2) to evaluate a specific site for effective coverage. Because each operating environment is different, it is almost impossible to predict the range without Site Testing. Before you permanently install any hardware, you should perform a Site Test to fully evaluate your planned area of operation. During the test the RF Terminal is transmitting 50 messages and waiting for acknowledgement from the Base Station. The Site Test evaluates the percentage of successful transmissions on the first and second tries from any given area. The higher the percentage, the more successful your communications will be from that area. Site Testing does not require your Base Station be attached to your Host Computer. All you need is your Base Station, 5v power supply and RF Terminal. For detailed information on how to perform a Site Test and use the results to determine the best location for your Base Station, go to Chapter 4; Performance Issues.
3-5
Page 52
Page 53
Chapter 4
Performance Issues Evaluating your area of planned operation Since every operational environment is different, it is impossible for us to tell you exactly what equipment you need and where you should put it to achieve maximum performance from your RF System. Site Testing was developed so that the user could start with a minimum system (RF Terminal and Base Station) and determine for themselves what their realistic operating range is, what additional equipment they need, and where to install their Base Stations to achieve optimum performance. Some other manufactures require expensive Site Tests before you can even purchase any equipment from them. Our Site Testing allows you the flexibility to Site Test whenever you choose, whether it is before you install your system or during operation to troubleshoot RF problems. Site Testing is the most valuable tool you have to help you achieve an efficient RF System with maximum range. There is also some basic information about Radio Frequency itself that can help you make smart choices about the location and composition of your system: • Metal walls are almost impenetrable by RF. If your warehouse computer is located in a metal shed, don’t locate the Base Station inside with the computer. Run a serial cable outside the metal shed and locate the Base Station there instead. Elevator shafts have similar signal-blocking problems. • The more walls you try to transmit through, the more the signal breaks down. Walls that have metal studs (interior office walls) and concrete walls with steel rebar slightly degrade the signal with each wall you try to go through. Metal walls may require the use of Relay Stations to achieve adequate range. • Organic material absorbs RF energy. If you are trying to operate in an area with lots of densely packed organic material (bags of beans or corn), expect and plan for reduced operating ranges. • 900MHz Spread Spectrum Phones. These phones will choke all frequencies that the RF Terminal uses. Switch to 2.4GHz phones. They are cheap to replace. There are some additional measures (other than a Site Test) you can take early on to maximize your range:
4-1
Page 54
• Base Stations should be located at the center of the area of intended coverage. This applies to Relay Stations also (see later in this chapter for more about Relays). If they are not located in the center, they should be tilted in the direction of use. • Raise the Base Station. Sometimes just raising the Base Station 12 feet will dramatically increase your operating range, especially in a warehouse or grocery store environment. Mount the Base Station on the ceiling with the antenna pointing down if you can. • Make Sure All Terminals are at least up to RFx9077J. This firmware and later releases reduce the radio contention by 50%.
Performing a Site Test As we have said before, the Site Test is your most valuable tool for evaluating your planned area of operation. All you need to perform a Site Test is a RF Terminal, a Base Station and its 5v power supply. There are a few things you need to do though before you begin: • Make sure all other Base Stations and Relays are turned OFF. • Make sure that the Base Station and RF Terminal you are using are set to the same frequency. Base Stations and RF Terminals are shipped from the factory set to frequency 0. If you need to change the frequency, see Appendix A; Frequency and Jumper Changes. • It is best to have a site map and several different colored pens to record the results of your testing. Each time you move the Base Station, record it’s location on the site map using a different color pen. Use the same color pen to record the test results for that Base location. The Base Station does not need to be connected to a host computer to do a Site Test. Simply connect the Base Station to wall power using the 5v power adapter. Locate the Base where you think you will have the best range and power it up. Turn on the RF Terminal and press a key at the opening screen. • Press NO at the SIGN ON? prompt • Press NO at the SETUP MODE? prompt • Press NO at the ONE WAY MODE? prompt • Press YES at the SITE TESTING? prompt If the Base Station is powered up, walk to the area where you want to perform your first test. When in position, stop and look at the RF Terminal display. It should read: Press Enter When Ready, F1 to Exit
4-2
Page 55
Press the ENTER key to start the test. Hold still during the test – moving around can result in inaccurate results. During the test the RF Terminal is transmitting 50 messages and waiting for acknowledgement from the Base Station. During the test the following message displays on the RF Terminal screen: Site Testing in Progress, Please Wait………….. Please Wait… will display on your screen until the test is finished. If it takes more than a few seconds, there is something wrong. When the test is finished, you will see the results displayed in the following format: 1st Try nn% Good 2nd Try mm% Good Press Enter When Ready, F1 to Exit The first line shows the percent of successful transmissions on the first try. The second line shows the percent of successful transmissions on the second try. If you are planning to use only one RF Terminal, even 50% successful on the second try is probably tolerable for most applications. If you were planning to use several RF Terminals in your system, 50% would result in long delays and would not be acceptable. Here are some rough guidelines you can use to evaluate your results: Number of Terminals in a given area
Minimum Acceptable Percentage
1
75% on 2nd try
2
90% on 2nd try
3
98% on 2nd try
4
80% on 1st try
5-8
95% on 1st try
9+
98% on 1st try
If you don’t get the minimum results shown above: 1. Try hanging the Base Station upside down or tilted toward the area of usage – this alone can double the effective range. 2. If you are close to the Base Station and your results are very poor, try a different frequency. You may find less interference on another channel. There are many to choose from, only try 1 or 2 others. 3. Try locating the Base Station closer to the area of difficulty. Remember that moving the Base Station will require you to recheck the other locations already tested. 4-3
Page 56
4. Plan for a Relay Station. Move the Base Station to where you would expect to place the Relay and try again.
Relay Stations Keeping all of the above factors in mind, using Relay Stations can increase your area of coverage by 5 times. Relays work like a remote antenna, passing data to the Base Station via cable instead of radio frequency. They don’t support Frequency Banks. Base Stations cannot be used as a Relay Station without changing the firmware and the jumpers inside. Relay Stations are attached to the Base Station using a cable that connects from the Base’s RELAY port to the Relays’ RELAY port. When you order a Relay Station, you receive a 3-foot test cable with it. Although Relay Stations will increase your range of operation, they will also add about ½ second to the response time.
How Relay Stations work… It helps to know how Relay Stations work before you add them to your system. Although Relays increase your operational range, they also slow the response time of your system. In order to use Relays, the Terminal must be configured to acknowledge that Relays are present. This is done using the Relay Existence setup parameter. By default, the RF Terminal is not configured to look for Relays. This setup parameter can only be accessed via the RF Terminal keypad it cannot be configured using the bar coded RF Terminal Setup Menu. See Chapter 2; RF System Setup for details. Once the RF Terminal is Relay-ready, it can use the Relay instead of the Base Station to communicate. If a RF Terminal tries to transmit 10 times to a Base Station without a response, it broadcasts a “who can hear me” message. If both the Base Station and the Relay hear the message, whoever answers back to the RF Terminal first becomes the point of contact for that RF Terminal.
4-4
Page 57
Once a RF Terminal has established communication with a Relay, it addresses that particular Relay until another communication failure (10 transmissions with no response) occurs. If a Base Station is within hearing distance of the RF Terminal, it will ignore messages meant for the Relay. When a Relay receives data from a RF Terminal, it then transmits that data to the Base Station over RS-422 twisted-pair cable. The Base Station in turn transmits data (via cable) for that RF Terminal to the Relay, for subsequent broadcast to the RF Terminal. Relays are “dumb”. Relays do not know whether a transmission was received by the Base Station or not, so it is up to the RF Terminal to retransmit its data if it does not receive a message from the Host Computer (via the Relay). The Relay can recognize data from the Terminal though and if it receives 10 retransmissions from the RF Terminal, the Relay assumes that the Base Station cannot hear it and broadcasts the message: RELAY n CANNOT BE HEARD BY THE BASE NOTIFY SUPERVISOR PRESS ANY KEY At this point, the RF Terminal puts out the “who can hear me” message. The RELAY n CANNOT BE HEARD message usually indicates a cabling problem and should be checked out immediately. Sometimes a Relay gets a response from the Base Station that is partial data or garbage. The Terminal retransmits its data since it has not received a new prompt. If this occurs ten times, the RF Terminal broadcasts, “who can hear me”. At this point the Relay is still functioning and answers the RF Terminal’s call. Should the Relay respond to the RF Terminal first, the whole sequence starts again. If the Relay again gets “garbage” messages from the Base and the Terminal re-transmits 10 times, then the Relay concludes that there is something wrong and broadcasts the RELAY CANNOT BE HEARD message. This situation indicates that you may have an electrical “noise” problem – check your cabling as well as any electrical equipment that is in the area.
Determining coverage areas for Base Stations and Relays As we said before, it is almost impossible to predict the effective RF communications range in a given environment. The typical area of coverage is a 400-1000 ft. radius.
4-5
Page 58
After a Site Test, if you have determined that you will need to add Relays to cover the area you want to operate in, you will need to determine where to place your Relay in relation to your Base Station. To effectively cover an area, there must be overlap between the area covered by the Base Station and the area covered by the Relay. The example below shows what can happen with no area overlap:
As you can see, the only area adequately covered is in a path where the two circles touch. The “dead space” is completely without coverage. Alternatively, locating the Base Station and Relay as shown below results in better coverage: To Site Test a Relay, all other Relays and Base Stations must be turned off.
This is the only way to know for sure which Relay is responding. Alternatively, perform the Relays’ test out of range of the other Relays and Base Stations.
4-6
Page 59
Relay Installation Relay Stations are connected to the Base by twisted-pair wire. See Appendix B: Adding Relays for the pin outs and a testing plan.
Dealing with radio traffic contention Radio traffic contention is the other most common hardware related problem you may have. If tested and configured properly, a single RF Terminal operating with a single Base Station should be no problem. Regardless of how frequent the scanning or data entry, radio signal contention is not a serious problem with two terminals per base. But if you have multiple terminals on a Base and two terminals happen to transmit exactly at the same time, a collision will occur and neither transmission will get through to the Base without automatic re-transmission and associated delays. Operating with multiple terminals on one Base station increases the chance for delays due to radio signal contention. A typical RF Terminal application consists of scanning or data entry followed by movement (i.e. going to another area) or manual activity (i.e. loading items in a truck) lasting several seconds. This means there is usually several seconds between each data transmission on a Terminal. The number of seconds between data transmissions on a Terminal determines the number of Terminals that can share the same frequency without significant delays. The following chart outlines the number of terminals possible on a Base Station based upon the “average” transaction rate: (this chart assumes a firmware version of RFx9077J or higher) Average number of seconds between transactions on a single Terminal
Number of Terminals possible on same frequency/Base
1 2 3 4 5 6 7 8
2 4 6 8 10 12 14 16
Be very careful when coming up with an “average” time between transactions. You should always use an average based upon your peak activity time. For example, let’s say that your business operates from 7 am to 5 p.m. Your RF Terminal operators start scanning at about 7:00, working continuously, averaging 3 seconds between transactions until 10:00, when operators begin taking breaks or moving on to work on other projects. Scanning is slow until 5:00, averaging 16 seconds between transactions. If you take an average over the whole day, your average would appear to be about 12 seconds between 4-7
Page 60
transactions, and using the chart above, you would assume you could safely run 16 terminals from one Base. But what about the peak time of 7:00 to 10:00, when transactions are only 3 seconds apart? Running 16 terminals per Base would cause significant delays during your peak time, extending the amount of time it takes to do the same amount of work. The safer bet is to use your peak time to calculate your average; in this case, you could efficiently run 6 Terminals on each Base without significant delays. Each Base station can accommodate up to 16 terminals - as you can see, the restricting factor is the number of transactions you need to perform per second. If the number of Terminals you can run based upon the average transaction time isn't acceptable, you need to add another Base station (or 2, depending upon what an acceptable transaction time is for you) and split your terminals between them. High volume systems probably require additional Base stations. Adding an additional Base station requires another serial port(s) or even another host computer in many instances. Only one Base station per serial port is allowed you cannot multi-drop or daisy-chain Base stations. Each Base station (and it's associated terminals) operating in a given area must also be operating on a different frequency. A common configuration has multiple workstations running a network application, with each workstation running a Base station and associated terminals on a unique frequency. The great thing about the RF Worth Data R/F Terminal system is that you can easily add additional Base stations at very low cost.
4-8