The text of a manual · part 12 of 19
Worth Data R/F Terminal Owner's Guide, pages 111 to 120
Pages 111 to 120 of 180
The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.
For the Worth TriCoder LT71
Page 111
• Try reading the following bar code below as an example of a known “good” bar code. This bar code is a Code 39 bar code and is readable by the RF Terminal set to its default settings.
• Make sure your bar codes have clearly defined dark bars and clean white spaces. If the bars are so light that they are gray instead of black or are so dark that they “bleed” into the white spaces, the printing of the bar codes is the problem. Whoever is printing the bar codes needs to make the necessary corrections. • The bar code should also have a “quiet zone” of at least ¼” to the left of the first bar and to the right of the last bar. Make sure to start your scanning to the left of the bar code in the “quiet zone”, moving the scanner quickly and smoothly as if drawing a line through the bar code. If using a laser scanner or CCD scanner, make sure the beam covers the bar code completely. • Make sure you are using the correct type of scanner for the type of bar code you are reading. If you are using an infrared wand, your bar code must be printed using infrared-quality ink. • If using a wand scanner, clean the tip. You would be amazed at how many wands we see where the only problem is that it needs to be cleaned. You would also be amazed at what we have found inside the tips of some of these wands If using a laser or CCD, clean the window of the scanner with a soft cloth.
If you have a problem… • Save the shipping box. If you ever need to send the RF Terminal or any of its’ parts back for repair, you will need the original shipping box. • If you have a problem with your RF System, consult the troubleshooting section of this manual FIRST. If you cannot find the answer here, call your Dealer or Worth Data for help.
8-8
Page 112
• Before you call your dealer or Worth Data for technical support, have your RF Terminal and related equipment in front of you and be prepared to explain your problem in detail to the Technical Support Engineer. • The Engineer may ask you to go through some troubleshooting procedures while on the telephone. This will help them determine what is wrong and what the course of action should be. Many problems can be resolved over the telephone and will not require that you return the equipment to us. If you do need to return any of the RF equipment to Worth Data, the Engineer will issue an RMA number. • If you do need to return the RF Terminal for ANY reason, you MUST have an RMA number first. Write the RMA number on the outside of the original shipping box and make sure to insure the shipment. All RMAs should be shipped back to the following address unless directed otherwise: RMA #XXXXXX Worth Data Inc. 623 Swift St. Santa Cruz, CA 95060 831-458-9938
8-9
Page 113
Appendix A
Frequency and Jumper Changes Opening a Base or Relay As preparation for changing the Base Station's frequency, baud rate, protocol, data bits, stop bits, and parity; or for changing a Relay Station's ID, frequency, or 422 termination, the case must be opened to expose the circuit board with the switches and jumpers. Be sure you disconnect power before starting. Turn your Base or Relay Station upside-down, and unscrew its single phillips head screw. If you don't completely remove the screw, you can use it as a lever to pull up on the cover.
Otherwise, insert a fingernail, credit card edge or small screwdriver blade into the gap between the Base and side of the case, and gently use it as a lever to lift up the edge of the Base. Then grasp the edge of the Base and open it outward like a door. This exposes the reader's circuit board, as shown below.
A-1
Page 114
Jumper Changes Refer to the circuit board diagram on page A-1 for reference. • JP103 controls the Programming Mode for the Base or Relay. For normal operation, leave this jumper in the Normal setting. To program the Relay ID or to program the Base Stations Computer Port settings from an R/F Terminal, move this jumper to P for Programming Mode. If the Base Station is jumpered for Programming, the user will be unable to "SIGN ON" for communication and will see the following message displayed: BASE IS JUMPERED FOR PROGRAMMING, CANNOT SIGN ON HIT ANY KEY If the Base Station is set for Normal, the user will be unable to setup the Base and will see the following message displayed: BASE IS NOT JUMPERED FOR PROGRAMMING, CANNOT SETUP HIT ANY KEY After changing the N/P jumper (JP103), you must cycle power on the Base Station or Relay for the new setting to take effect. After cycling power, you can enter SETUP MODE on the R/F Terminal and make changes to the Base Setup from the R/F Terminal. All changes to the Base Station must be made from the RF Terminal keypad only. This is to minimize confusion between setup of the R/F Terminal and the R/F Base Station. Refer to Base Setup instructions in Chapter 2; RF System Setup for instructions on how to make the baud rate, parity, protocol, etc. changes to the Base Station.
A-2
Page 115
RS-422 Termination Jumpers Refer to the circuit board diagram on page A-1 for details. The Base and Relay can be jumpered to be 422 terminated or not terminated. By default, all Base stations and Relay are shipped as terminated. Use the following guidelines to change the termination for your system: • If the Base has multiple strings of relays radiating from it, the Base would not be terminated. • If the Base is first in a string, (not in the middle or end of a string), set the 422 jumpers to Base w/RS-422 termination. • The last Relay in each string should have its jumpers set as a Relay w/RS-422 termination.
Frequency Changes To determine the current frequency of a Base Station or Relay, power up the Base or Relay and watch the LED light on the front of the unit. On power UP, a Base or Relay LED will blink "Frequency +3" times. For example, a unit that blinks 5 times on power up is operating on frequency 2. Frequency 0 blinks 3 times, frequency 5 blinks 8 times.
Changing the frequency on a Base or Relay The Base Station and Relay must have their frequencies set to the same frequency as the R/F Terminals in their network. The frequency is set on a Base or Relay by turning a rotary switch to the setting 0-F (16 different frequencies to choose from). Jumper JP103 should be set to Normal when making this change. Use a very small flat head screwdriver to turn the switch to the desired number. See the circuit board diagram on page A-1 for location of the rotary switch
Setting the Relay ID Each Relay must also have a unique ID, which is also set by turning the rotary switch, but is a little more complicated than setting the frequency: • Move Jumper JP103 to P (for Programming) • Move the Rotary Switch (SW1) to a position (0-F) to correspond to the ID to which you wish to set the Relay Station. • Now cycle power on the Relay Station. • Set JP103 back to N (for normal) and restore the Rotary Switch to the frequency setting on which you intend operate the Base Station and Terminals in the network.
A-3
Page 116
Hardware changes on the RF Terminal To change the Laser decode light operation or the speaker volume, the case of the R/F Terminal must be opened. Before opening up the R/F Terminal, be careful of static discharge to the board by grounding yourself (at least touch some large metal object) immediately before opening the case. To open up the R/F Terminal, unplug the power supply and turn the R/F Terminal OFF. Unscrew the four screws - there is one in each back corner. Lay the two halves of the R/F Terminal on a desk like the diagram below.
• JP3 is the Laser Decode Light jumper. The RF Terminal is shipped with the decode light on the laser scanner deactivated so that the RF Terminal can operate interchangeably with a wand or laser. If you want to restrict the RF Terminal's operation to a laser scanner only and have the decode light activated, simply move the jumper JP3 from W to L. A-4
Page 117
• JP4, the Battery Recharge Jumper, exists on the LT71/T71 only, (the LT73/T73 is only recharging). This jumper's setting is determined by what type of batteries you plan to use in the RF Terminal. Either alkaline (including Alkaline rechargeables), Nickel Metal Hydride rechargeable batteries or NiCad rechargeables may be used. If you are using rechargeable batteries, there is recharging circuitry built in to the R/F Terminal. To use the recharging circuitry, you must change jumper JP4, then plug in our F10 5v Power Adapter. The F10 Power Adapter is a separate item and must be ordered in addition to the R/F Terminal. By default, the R/F Terminal is set up to use regular Alkaline batteries with the recharging circuitry OFF. If you are going to use the recharging feature, be VERY CAREFUL to double-check the jumper setting. Plugging the power supply in when you have regular Alkaline batteries in the R/F Terminal but the jumper set for recharging can cause some serious damage. Only use rechargeable batteries (Alkaline, NiMH, NiCad) if using the recharging feature. The jumper inside the R/F Terminal is located above the AUX jack and is labeled JP4. The jumper must cover BOTH pins in order for the recharging to work. See the diagram of the R/F Terminal on the previous page for details on JP4's location. Recharging takes approximately 8 hours for a full charge if batteries are fully discharged first. If you decide to use rechargeable batteries, be sure to change the setting in Speaker/Batteries to rechargeables to avoid many problems. • The volume of the speaker can be increased or decreased in loudness by adjusting a tiny potentiometer inside the R/F Terminal. Locate the volume adjustment, (right next to the speaker jack) and make adjustments within the red lines marked on the potentiometer. Use a knife or a very fine blade flat screwdriver to turn the volume control. Turn it clockwise to increase volume. Turn it counter clockwise to decrease the volume. If you are in a noisy environment, you may prefer the T12 Headphone, which plugs into the AUX jack on the bottom of the R/F Terminal. If using the headphone, you will probably want to turn off the speaker to conserve power. You can do this by entering the SETUP MODE and specifying 1 for Speaker OFF. You can control the Headphone volume independently by using the volume control built into the Headphone cable.
A-5
Page 118
Page 119
Appendix B
Adding Relays Connecting a Relay Station How it works… A Relay station allows you to extend the area of your R/F coverage. Relays are connected by cable to the Base station, acting as a remote antenna. More than one Relay can be added by “multi-dropping” additional Relays. Using a Relay requires changing the setup on the Base station in addition to added cabling. The diagram below shows how Relays are added:
Although Relays will extend your R/F range, they do slightly slow down your response time. If response time is your problem, Relays may help only if the problem occurs on the outer limits of your range. Use Site Testing to help you determine if adding a Relay will help. If you are considering Relays, read Chapter 4; Performance Issues first. If adding only one Relay, the cabling should run between the RELAY port on the Base station and the RELAY port on the Relay. In this example, both the Base Station and Relay should have jumpers set to “terminated”.
B-1
Page 120
To add additional Relays, you must “multi-drop” them off a single bus line running from the RELAY port on the Base station. See the section below for cabling requirements and pin-outs. It is very important to follow the pinout directions carefully and to use the suggested cable type. The majority of problems we see are the result of incorrect wiring. Each Relay requires it’s own power supply. There is no serial parameter setup required on a Relay as it is transmitting only to the Base station and not directly to a serial port.
Routing the Wiring The below diagram illustrates the RIGHT way to route your wiring and which units should be terminated. Notice this is the classical bus interface where the Base and Relays are connected to a “one-cable bus”. The bottom of the Y-Cables is connected into the unterminated base or relay(s). Notices that the two end units are terminated; the units in the middle are unterminated, including the Base in this example.
Correct Routing for Wiring
B-2