The text of a manual · part 11 of 19

Worth Data R/F Terminal Owner's Guide, pages 101 to 110

Pages 101 to 110 of 180

The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Worth TriCoder LT71

Page 101

Assigning Error Messages Error Messages are recorded the same way other messages are - by going into RECORD/PLAYBACK, selecting a message number and recording a voice message. The RF Terminal comes from the factory with some voice prompts and error messages pre-recorded. You can change any of these messages but keep in mind that the error conditions are hardware-related and that the voice error messages they are linked to are fixed. For example, the “Low Batteries” message is located at message #31. Whenever the RF Terminal detects very low batteries, it will play message #31, regardless of what is recorded there. You could record “Happy Birthday” and the RF Terminal would broadcast it any time it detected the low battery condition. To avoid confusion, try to keep the error messages somewhat related to the error condition they represent.

Default Voice Messages Here are the default messages and the message numbers they are recorded under: Message Recorded

Message #

Prompts

ITEM QUANTITY

#01 #02

Error messages

LOW BATTERIES CHANGE BATTERIES TRANSMISSION FAILED

#31 #32 #33

Cloning Voice Messages and Setup from RF Terminal to RF Terminal If you have several RF Terminals, you can record all of your voice messages in one RF Terminal and then simply “clone” them to your other RF Terminals. Cloning also copies the RF Terminal setup (except for Terminal ID). You need 2 cables to clone RF Terminals; the Data Cloning Cable #F38 and the Voice Cloning Cable #T15. The Data Cloning Cable plugs into the “Computer” port on each RF Terminal. This cable must be connected to clone properly. One jack on the Voice Cloning Cable has two black rings on it – this end must plug in to the RECEIVING RF Terminal (the one you are transmitting to). Plug the single-banded jack end into the MASTER RF Terminal (the one you are going to record from). Once both cables are plugged in to both Terminals, go to the Setup Menu on both Terminals. Select 3 for Voice Operations from the menu. 7-5

Page 102

The “Receiving” RF Terminal must be started first. On the receiving Terminal, press the 4 key for Cloning Receiver. The “Receiving” unit will display: Recv Setup/Voice Please Wait_ Now you can start the “Master” RF Terminal by pressing the 3 key for Cloning Master. The “Master” Terminal will display: Xmit Setup/Voice Please Wait_ During the cloning process, you will hear the voice messages played aloud as they are copied. The process takes about 75 seconds to complete. After the Terminals are done cloning, they will both display: End of Cloning Hit Any Key_ If you did not hear the correct messages or you heard no messages at all, check your cables and receiver/master setup - you may have transmitted from the wrong RF Terminal. DATA XMIT ERROR CYCLE POWER If you get the DATA XMIT ERROR message, you have to restart the whole cloning procedure. Changing the Speaker Volume The volume of the speaker can be increased significantly by adjusting a tiny potentiometer inside the RF Terminal. Changing the speaker volume also changes the headphone volume. The Headphone is an optional feature, Part #T12, and can be ordered with the RF Terminal or separately afterward. The #T12 Headphone also has a volume control built into the cable that will change only the Headphone volume. Because static discharge can cause damage to the RF Terminal’s circuit board, it is recommended that you use a ground strap or other grounding device when you are touching the inside of the RF Terminal. To open the RF Terminal, turn the Terminal OFF and remove the four screws on the back (one in each corner). Lay the connected halves of the RF Terminal on a desk or flat surface. You now have access to the Flash RAM EPROM and several jumpers as well as the volume potentiometer. Using the figure below, locate the volume control and make adjustments within the red lines marked on the potentiometer. Use a knife or a very fine blade flat

7-6

Page 103

screwdriver to turn the volume control. Turn it clockwise to increase volume or counter clockwise to decrease the volume.

If you are in a noisy environment, try using the headphone that plugs into the AUX jack on the bottom of the RF Terminal. When using the headphone, you can conserve power by turning off the speaker. Go into the SETUP MODE, Speaker Operations and specify 1 for Speaker OFF. If using the #T12 Headphone, you can adjust the headphone volume independently using a volume switch built into the headphone cable.

7-7

Page 104

Chapter 8

Troubleshooting General Considerations Site Test The most basic tool for troubleshooting is the Site Test at 30 feet range. (See Chapter 4 for the details on how to do a Site Test). If the Site Test fails at close range (30 feet), you have found the problem. The radio on either the Base Station or the RF Terminal is defective. If the site test works at 30 ft., but not at 50-100 feet, it could be interference from another radio source such as a 900 MHz phone. Take the Base and Terminal to another location to see if the site test still fails, (maybe home with you that evening). If you have multiple terminals and multiple Base Stations, after site test failure, you can determine if the failure is with the Terminal or the Base by substitution. If you have only one Terminal and Base, you have no way of knowing which has failed; you must call us and get an RMA for both units to be checked out at the factory in Santa Cruz or in Ireland. If the Site Test passes, there is nothing wrong with the radios.

Changing Batteries For RF Terminals, the most frequent cause of problems is low batteries that have either been ignored or undetected. The real test for batteries is to remove batteries from a working unit and place them in a suspect unit. Don’t assume that just because the batteries are new they are good. We have purchased “new “ batteries off the shelf and tested them immediately to discover they are bad. Most of the time batteries become the problem as a result of two failures: 1) The operator ignores the Low Batteries message and doesn’t finish up the transaction and immediately change the batteries. If you turn the unit off and turn it on again, the batteries may have had time to “almost” recover. Unfortunately they will have so little reserve power that they will likely operate just long enough to produce some very screwy behavior on the RF Terminal. Intermittent laser beams, continuous beeping, black bars on the screen, etc. are just a few of the disastrous symptoms that can be exhibited. 2) NiCad or NiMH rechargeable batteries are being used, but the Terminal thinks that Alkalines are still being used. The Terminal ships with Alkaline batteries in the Setup. Alkalines and rechargeable batteries have different reserve powers, so the Terminal has to know if you have decided 8-1

Page 105

to use rechargeables in order to properly notify you that the batteries have reached the low point requiring the batteries to be changed. If you are using rechargeable batteries, you must change the Speaker/Batteries parameter in the Terminal Setup to reflect the usage of rechargeable batteries, otherwise you will strange behavior on the Terminal including: Intermittent laser beams, continuous beeping, black bars on the screen, etc. See Chapter 2: Speaker Batteries to change the setting. To display the remaining battery life of the AA batteries and the type of batteries the Terminal is expecting, press the STATUS key shows:

x=a when Alkaline batteries are specified in Speaker/Battery setup x=n when NiMH or NiCad batteries specified in Speaker/Battery setup Press the STATUS key again to resume processing.

Problems with a new installation: If the Terminal displays the “Waiting for Base to Acknowledge” message, your radios are not communicating. Be sure they’re on the same frequency and then try a Site Test at close range. If the Site Test fails at 30 feet, one of the radios is dead. If you have multiple terminals, try another terminal. If the 2nd terminal also fails on the same frequency, the base station is bad. If the 2nd terminal passes the Site Test, the first terminal is bad. If the Terminal displays the “Waiting on Host Prompt” message, the host program is not communicating with the Base Station. There is no radio problem, because the Base Station has already acknowledged the Terminal’s Sign In. The Terminal is waiting on the Host to tell it to do something. Try the demo program; if it works the problem is your program. If the demo program fails, the problem is one of the following: 1) The cable between the Base Station and host computer is bad. Try the test with extension cables removed. 2) The host COM port is bad or assigned to another device driver installed. Try another COM port or try another computer. 3) RARELY !!!The RS232 chip (U101 location) on the Base Station is bad. If you have other Bases, swap these pluggable chips to see if the problem goes away.

8-2

Page 106

Terminal Error Messages Message

Meaning – Action Required

”Waiting for Base to Acknowledge...?”

Radios in Base and Terminal are not communicating. Be sure they are on same frequency. Do Site Test at 3 feet from Base. If Site Test fails, the problem is with Base or Terminal radio. Problem is between Host computer and Base station. Check to see if host application is running. Check serial parameters and eliminate any extension cables. Run the Demo program. Try another COM port or another computer. Problem is in host program. Notify programmer! If the Base Station receives 5 Sequence Errors in a row, it transmits the message to all terminals signed in and shuts down. Check your host program for the sequence error before starting up again. OR If the Base Station receives 5 messages addressed to a Terminal not Signed ON, it transmits this message to the all terminals signed in and shuts down. You will have to cycle power on the Base Station or you can send a command (*@EOT) form the host and have the Terminal Sign On again to continue. See Chapter 6, page 6-8 for more information on Sequence Errors. Base Station has been reinitialized. If message reads “Base Reinitialized P”, then reinitialization is due to a power problem. If “Base Reinitialized H” then the reinitialization was initiated by the host program. (if base is dlx9079 +). Fix problem (cycle power on Base or re-initialize from host program). This message is also occurs erroneously if you try to Sign On with a 6 line terminal in 6 line mode to a Base Station that is lower that DLx9075

“Waiting on Host Prompt”

“Base Station Shut Down Due to Host Logic Error, Cycle Terminal Power”

“ Base Reinitialized X Cycle Power on RF Terminal and Sign-on again to Restart_”

“ Buffer Reinitialized Cycle Power on RF Terminal and Sign-on again to Restart_”

The host program has reinitialized the buffer in the Base Station for this terminal only. The Base is still operational and ready for you to power off your terminal, power on, and SIGN ON again. Other terminals are not affected.

LOW BATTERIES Finish, Sign Off Change Batteries

Finish the transaction you have started. The Press F1 to Sign Out. Then turn off the Terminal and change the batteries.

CHANGE BATTERIES UNIT SHUT DOWN

The terminal will display this message for 20 seconds, sign out, and turn off. Change the batteries immediately. Don’t let someone else pick it up and operate with partially recovered batteries

8-3

Page 107

Message

Meaning – Action Required

Relay n Cannot be Heard by the Base Notify Supervisor

The terminal has established contact with Relay Station x. Relay Station x has attempted to communicate with the Base Station through the 422 cabling with no success. Cable is bad.

Transmission Failed To Retry, Move Closer And Press Enter

The terminal has tried 10 times to get its message through to the Base Station with no success. Could be result of bad radio in base or terminal. Could be the operator has gone out of range of the base- if so, move closer and press any key. Could also be that there are too many terminals competing for radio time on one base station. Sign On is not allowed if the Base is already in some other mode such as One-Way or Site-Testing, which was not properly concluded. Cycling power on base clears. Is another Base giving you this message?

Two Way Not Allowed Base in Other Mode Press <Enter> Key One Way Not Allowed Base in Other Mode Press <Enter> Key Site Testing Not Allowed, Base in Other Mode Press <Enter> Key Base is not Jumpered for Programming Cannot Setup

One-Way is not allowed if the Base is already in some other mode such as Two-Way or Site Testing which was not properly concluded. Cycling power on base clears. Site Testing is not allowed if the Base is already in some other mode such as Two-Way or One-Way which was not properly concluded. Cycling power on base clears.

Press <Enter> Key

The Base must have JP103 set to P before it can be Setup through the Terminal. If Jumper is set correctly, there must be another base answering. Turn off the suspect base and try signing in again. If you get the same message, another base is on.

Base is Jumpered For Programming Cannot Proceed Press <Enter> Key

The Base jumper (JP103) is set to P for programming. Base jumper JP103 must be set to N for normal usage, (non-programming). If jumper is correctly set, there must be another base answering. Turn off suspect base and try again.

No Firmware Detected 1 – Download Firmware 0 – Power off Terminal Press 0 or 1 now_

The firmware has somehow been wiped out – probably from an interrupted firmware download. Press 1 to Download Firmware or press 0 to power off the terminal.

Two or more terminals with the same ID can generate all kinds of strange messages including those shaded above. Two bases on the same frequency are big trouble. Sometimes you get an error message and after checking, everything on the Base seems to be set OK. Drop power on the suspect Base and try signing in again. If you get the same message, there is another Base answering which should not be on the same frequency. 8-4

Page 108

Troubleshooting specific problems Communication Problems I can’t communicate at all... • First, check the communication link from the Base Station to the host. Use the following command to test the transmission of data from host to Base and back again to the host: @@*Edataaaaaaaa<EOT> where dataaaaaaaa is any string of data, terminated by EOT. This string should be sent from the host to the Base Station. If the data is received by the Base, it echoes it back to the host in the format: dataaaaaaaa<CR> where dataaaaaaaa is the data string from the original transmission, terminated by a CR (ASCII 13). This test verifies communication in both directions (host to Base, Base to host). • If the data isn’t echoed back, either your host COM port or the Base Station has a problem. Check that the Base Station is NOT jumpered for Programming. JP103 should be set to N, (Normal), not P. If it is set to P, no communication from host to Base and back will take place. • Once you know the Base Station is communicating with the host correctly, compare the frequency of the Base Station with the frequency of the Terminal. Use Site Testing to check the communication of the Terminal to the Base and back. Stay close, make sure no other Terminals are in use, and go to Site Test mode on the Terminal. You should get 96-100% on first try. If you don’t, it’s a good chance your radios need repair. Call Worth Data for an RMA. • If you are using PICK or UNIX as your operating system, make sure the Base Station is set to "XON/XOFF Sensitive".

My response time is poor... • First, do a Site Test right next to the Base Station. If it's not 98%, RF is the problem. • Second, run one of the demo programs. If the demo runs fast, it is your program that is slow. If your program is not responding within 300ms, the Terminal has to send periodic messages, waiting for a response. A host program that takes 2 seconds to respond to a Terminal with a new prompt will increase radio traffic by 400% - greatly reducing the number of Terminals you can accommodate on one Base Station. See Host Response Delay in the Setup (Chapter 2) for help in avoiding this problem. 8-5

Page 109

• If you have multiple terminals on one base and your Terminal firmware is not RFx9077J or higher, you should upgrade your firmware by downloading the latest off the website http://www.barcodehq.com on the downloads page. This will reduce contention between terminals by up to 50%. • If you have good response time everywhere but on the outer fringe area, you may need a Relay. • If you have several Terminals on one Base Station, consider adding another Base Station and splitting the Terminals to reduce contention. If you are running the RFDEMO program, the application response time is instantaneous, so any delays you see are due to radio traffic.

I'm not getting the distance I need... To maximize range, the Base Stations and Relays should be located: 1. At the center of the area of intended coverage, and 2. As high as possible - mounted on the ceiling of a room with the antenna pointing downward works the best. Sometimes just raising the Base Station to 12 feet will dramatically increase the distance, especially in warehouses or grocery stores with tall shelving. A Base Station mounted on the wall with the antenna parallel to the floor is the worst position. To accurately determine the hardware required to cover a particular area, you should use the Site Test mode built in-to the RF Terminal.

I can't communicate with the RS-232 port on my host CPU... • This is one of the biggest problems called in. If you are not using our cables, check your cables first. If you have an extension cable, remove it for testing. If you have an extension cable of 80 feet or more attached to a Windows host, you need to be sure certain pins are not attached in the DB9 or DB25. See Appendix C; RF Serial Pin-outs. • If you are using the PICK or UNIX operating systems, be sure you have set the Base Station to be "XON/XOFF Sensitive". You need to do this to prevent the XOFF code being sent as a "Base Initialization" message. • Windows 95,98,2000,ME, NT; COM port setup should also be changed to turn off XON/XOFF. XON/XOFF is the default for Windows. You set these through the control panel, System, Device Manager, Ports (COM & LPT), COM Port, Port Settings, Flow Control. Set Flow Control to None.

8-6

Page 110

RF Terminal Problems The laser beam won’t spread when I press the trigger, OR My keypad is dead, OR I get black bars on the display when I turn it on, OR When I turn it on, it just beeps continually. •

Change to known good batteries, preferably out of a working unit and try again.

The unit won’t power up with batteries (good batteries) but it will power using the Base Station power supply •

Your battery terminals inside the case may be corroded with battery acid or just contamination. Open up the case and clean the battery terminal s with alcohol soaked cloth.

I get 6 beeps when the RF Terminal powers up... • The unit needs repair. Call Worth Data for an RMA.

Problems reading Bar Codes The reader won't beep when I try to read bar codes... • Try reading a known good bar code - try the 1 on the Setup Menu bar pad table. Follow the steps for proper scanning technique discussed in Appendix M; How to scan a bar code. • If using a wand scanner, try scanning at different speeds - a common error is to scan too slowly. • Make sure the reader is configured to read the type of bar code you are trying to scan. Most bar code types are disabled by default and need to be enabled using the Setup Menu or keypad while in Setup Mode.

I get extra characters at the beginning or end of my bar code data... • Clear the Preamble and Postamble settings.

I have very poor read rates when scanning bar codes... • Carefully follow the scanning instructions in Appendix M; How to scan a bar code when reading any and all bar codes. As straightforward as scanning may seem, many people who call with a complaint about poor read rates simply aren't doing it right.

8-7