The text of a manual · part 10 of 19

Worth Data R/F Terminal Owner's Guide, pages 91 to 100

Pages 91 to 100 of 180

The original document is the PDF (2.1 MB). This is its text as extracted, unedited; tables and drawings read best in the PDF, and each page heading opens it at that page.

For the Worth TriCoder LT71

Page 91

ReInit

Parameters: Function:

basename, channel, terminal This instructs the terminal attached to client basename on channel to re-initialize. Must be followed by an "Input" method call to take effect. NOTE: Base Stations using EEPROM versions prior to 9079 will cause the message "Base Reinitialized..." to be displayed on the terminal. Only the terminal has actually been re-initialized. Later Base Stations use the message "Buffer Reinitialized..." to indicate a single terminal reinitialization.

ReInitAll

Parameters: Function:

basename, channel This instructs all terminals attached to client basename on channel to re-initialize.

TestClient

Parameters: Function:

none This instructs the Server to "ping" all attached clients. Results are recorded in the log.

Events WDIPterm events occur when a specific condition is met. When an event is "fired", an event handler function in your application is called. Though the details of exactly how it is done varies from one programming environment to the next, the source code skeletons for the various event handlers are automatically generated and inserted into your source code for you. See the samples for more specific information. Each event passes relevant information to your event handler function. OnTermData passes the data that was keyed or scanned into the terminal. Terminal ID is always passed as 0-15. A terminal ID value of 99 is used as a placeholder for logging purposes. Once you have the event handler skeletons, you can proceed to add whatever functionality you desire to each event. You must set the ServerOn property to true before any events can be fired. OnTermBaseRegister

Data passed: Event:

basename, channel A base station on client basename has successfully powered up on channel and communicated with the host computer via the serial connection.

6-27

Page 92

OnTermSignIn6

Data passed: Event:

basename, channel, terminal A six-line terminal has signed in on channel at client basename. Terminal ID is passed in terminal.

OnTermSignIn4

Data passed: Event:

basename, channel, terminal A four-line terminal has signed in on channel at client basename. Terminal ID is passed in terminal.

OnTermSignOut

Data passed: Event:

basename, channel, terminal A terminal has signed out on channel at client basename. Terminal ID is passed in terminal.

OnTermData

Data passed: Event:

basename, channel, terminal, data A terminal on channel at client basename has sent data in response to an Input method call.

OnTermNotSignedIn

Data passed: Event:

basename, channel, terminal A command has been sent to a terminal that is not signed in.

OnTermSequenceError

Data passed: Event:

basename, channel, terminal The one-for-one host prompt/terminal response protocol has been violated. The host cannot send a second Input command until it has received a response from the first Input command. If a base station receives 5 sequence errors in a row, a Host Logic error is generated and the base shuts itself down. While PromptNET/ActiveX will intercept and prevent most logic errors, they are still possible so you should implement this event handler!

OnTermIllegalCommand

Data passed: Event:

basename, channel, terminal An illegal command has been sent to a terminal. PromptNET/ActiveX is designed to prevent illegal commands but we may not have imagined all the ways in which our customers will want to use it!

OnTermUpArrow

Data passed: Event:

basename, channel, terminal The up-arrow button has been pressed on a terminal. You must issue another Input method call before WDIPterm can respond to another keypress on this terminal. 6-28

Page 93

OnTermDownArrow

Data passed: Event:

basename, channel, terminal The down-arrow button has been pressed on a terminal. You must issue another Input method call before WDIPterm can respond to another keypress on this terminal.

OnTermLeftArrow

Data passed: Event:

basename, channel, terminal The left-arrow button has been pressed on a terminal. You must issue another Input method call before WDIPterm can respond to another keypress on this terminal.

OnTermRightArrow

Data passed: Event:

basename, channel, terminal The right-arrow button has been pressed on a terminal. You must issue another Input method call before WDIPterm can respond to another keypress on this terminal.

OnTermBeginKey

Data passed: Event:

basename, channel, terminal The BEGIN button has been pressed on a terminal. You must issue another Input method call before WDIPterm can respond to another keypress on this terminal.

OnTermEndKey

Data passed: Event:

basename, channel, terminal The END button has been pressed on a terminal. You must issue another Input method call before WDIPterm can respond to another keypress on this terminal.

OnTermSearchKey

Data passed: Event:

basename, channel, terminal The SEARCH button has been pressed on a terminal. You must issue another Input method call before WDIPterm can respond to another keypress on this terminal.

6-29

Page 94

Portable Printers Cameo and Encore Common Information Both of these printers are stocked by Worth Data for the convenience of our users who need portable printing. These printers do not require any special protocol; they do not require the “wake-up byte” as do other printers. They do require a special cable that can be ordered from Worth Data (part #C12); cable pin-outs are available in Appendix C: Cable Pin-outs. These printers require a hardware modification to the RF Terminal in order to work. You can determine if your Terminal is Cameo/Encore ready by looking at the third line on the opening screen where Frequency is displayed. It there is a Z to the right of the frequency number and display lines, your terminal is Zebra Cameo or Encore ready. If specified at the time of your RF Terminal order, there is no charge for the modification. The modification is available for RF Terminals you already own; the cost is $85 because the RF Terminal must be returned to us for modification. Call us for an RMA number before sending it in. Shipped with every Cameo or Encore printer ordered is a CD ROM with the Programmers Manual in PDF format and a label design program – LabelVista. This program allows you to design the program and create multiple format files that can be sent to the printer where they become resident in flash. Variable fields are defined and can then be filled in by the program when in operation. Keep in mind the following information when using these versatile printers: •

The printer turn on ("Wake-up") is accomplished by the RF Terminal toggling the DSR line on the printer, so only the @S command and the data you are sending to the printer is needed.

•

Once the RF Terminal has turned on the printer, it stays on until the host program turns it off using the POWER OFF COMMAND "ESC(0x1b)`p'(0x70)" described in the Printing Systems Programming Manual, or until the automatic shut-down takes place (2 minute default).

•

The 247 character limit applies to your command string. See your Portable Printing Systems Programming Manual for details on programming your printer.

Zebra Cameo Printer The Zebra “Cameo ” Printers are portable direct thermal receipt printers, (not label printers – the Encore below prints labels). Bar codes can be printed on the receipts, but you can’t print labels. 6-30

Page 95

One model of this printer is available with a magnetic stripe reader, allowing magnetic stripe input to the RF Terminal using the @R (serial input) command. •

The Cameo printer with magstripe input is capable of reading Track 1, Track 2 or Tracks 1&2. See your Portable Printing Systems Programming Manual for the correct character string to send in the @S command to turn on the magstripe reader. In order to receive magstripe input from the printer, you must then use the @R serial input command (see page 6-2 for details).

•

When the Terminal sends data to the host, it sends it in the following format: RF Terminal ID + DATA + CR

Typically, the data is simply a string of characters, but in the instance of data coming from the magstripe reader, there are some additional characters you need to be aware of. The magstripe reader sends its data in the following formats: Track 1: TRACK1 DATA + CR + LF

Track 2: TRACK2 DATA + CR + LF

Track 1&2: TRACK 1 DATA + CR + LR + TRACK 2 DATA + CR + LF

So, when the RF Terminal transmits the data to the host, it will be in the following format: RF Terminal ID + TRACK 1 DATA + CR + LF + CR RF Terminal ID + TRACK 2 DATA + CR + LF + CR and RF Terminal ID + TRACK 1 DATA + CR + LF + TRACK 2 DATA + CR + LF + CR

For some, the extra CR’s and LF’s will not pose a problem, but for others they may require you to do some additional programming in your host application. Again, see your Printing Systems Pro-gramming Manual on the CD ROM shipped with the printer.

Zebra Encore Printer The Encore Printer is used for label printing. It doesn’t have Magstripe input. The classic application is for printing shelf labels during shelf price verification: 1) The operator scans a shelf label. 2) The Terminal transmits scanned data to the host computer. 6-31

Page 96

3) The host computer looks up the price, description, etc. and transmits the computer price back and sends the necessary commands to the attached Encore printer to prints a new shelf label with the correct price. 4) The terminal operator then peels off the label and applies it to the shelf. Each printer is shipped with a no charge roll of thermal paper that can be used for development, including determining the exact label size that best fits you needs and the capabilities of the printer. We stock the 2” and 3” Encore printers with several label sizes immediately available including: Part Number E2L1 E2L2 E2L3 E2L4 E3L1 E3L2

Description 2"x1" Vinyl Shelf Adhesive Labels 2"x1.25" Paper Permanent Adhesive Labels 2”x2” Paper Permanent Adhesive Labels 2”x1.25” Vinyl Shelf Adhesive Labels 3"x1" Vinyl Shelf Adhesive Labels 3"x1.75" Paper Permanent Adhesive Labels

Price/ Roll $3.50 $2.50 $2.50 $3.00 $7.50 $5.00

Shelf adhesive labels are designed for ease of removal to facilitate replacement. Permanent adhesive labels are designed to stick and stay stuck, making removal difficult without leaving a residue.

6-32

Page 97

Chapter 7

Voice Message Operations The RF Terminal’s exclusive use of voice prompts allows you to overcome problems such as literacy, language and lighting. With proper planning, voice prompting can enhance your RF Terminal application, making it faster and simpler. Voice messages are recorded in the RF Terminal, and then triggered by a prompt from the host computer.

Why Use Voice Messages and Prompts? • Voice messages can be in any language. • The operator does not have to be able to read to perform some jobs. • Audible instructions can be heard in poor lighting where it is difficult to read a LCD screen. MOST IMPORTANTLY, the data collection process is faster because the operator does not have to continually look at the screen for instructions. This is especially useful when you do not want or need to enter data from the keypad. Scanning bar coded numbers from a Quantity BARPAD can make keying unnecessary. Voice messages and prompts are a good way to keep the operator’s attention focused on the job at hand. Audible error messages and warnings also help to limit mistakes and downtime.

Tips for Using Voice Prompts Over 90 voice messages can be recorded in the RF Terminal. Here are some tips on making your voice prompts user-friendly: • Short messages are preferable for prompts; most English prompts can be stated in ½ second. Instead of saying, “Enter the Item Number,” say “Item”. The typical RF Terminal operator does not want to hear long messages thousands of times. Error messages are typically longer because they are the exception and need to provide more precise instruction to the user. • Record your voice prompts calmly. A frantic sounding voice can become irritating, especially when heard repeatedly. • Speak clearly. Correct pronunciation will make the voice prompts easier to follow for all users. Use common words that all users will understand.

7-1

Page 98

• Vary the tone of your voice for different prompts. Using a different tone of voice or even a different voice for consecutive prompts or error messages will make it easier for the user to distinguish between them. • Be sure to record error messages for all possible problems that the user may encounter during a session. Once the operator becomes accustomed to listening to the voice prompts, it may become easy to overlook a “display only” error message.

RF Terminal’s Voice Message Mapping The RF Terminal is shipped with 75 seconds of total recording time. The time allotted for each message is partitioned as follows: 30 – ½ second messages (message numbers 01-30) 30 - 1 second messages (message numbers 31-60) 15 - 2 second messages (message numbers 61-75) Messages are sequentially numbered beginning with the ½-second messages, followed by the 1-second messages, and finally the 2-second messages. You can change the partitions to allow for more or less of a particular length message. For example, if you decide you do not want any ½ second messages and you want 15 more 1-second messages, your allocation would look like this: 00 – ½ second messages 45 - 1 second messages (message numbers 01-45) 15 - 2 second messages (message numbers 46-60) Voice message partitions are set in the RF Terminal either from the bar coded Setup Menu or by the keypad setup. From the Setup Menu, scan the bar code for “Voice Messages”, and then scan six digits. The first 2 digits correspond to the ½ second messages, the second 2 digits for the 1-second messages and the last 2 digits for the 2-second messages. See Chapter 2; RF System Setup for details on Terminal setup (by bar code setup menu and keypad). Remember that the total amount of time must add up to 75 seconds.

7-2

Page 99

Programming Voice Messages To record and playback messages or assign messages to error conditions, you have to get to SETUP MODE and enter the password. If you don’t know how to do this, see Chapter 2; RF System Setup for details on how to get into the SETUP MODE. Once you have entered the password (OK, its WDTRI) you will see the following prompt: R/F Terminal Setup->1 R/F Base Setup------>2 Voice Operations---->3 Press 3 to select Voice Operations. The next screen gives you your options: Record/Playback--->1 Assign Errors------->2 Cloning Master----->3 Cloning Receiver-->4 Pressing the “1” key takes you into the voice recording and playback function. Pressing the “2” key allows you to assign voice message numbers to error conditions. “3” and “4” allow you to clone voice messages from one RF Terminal to another. Each option is shown in detail below:

Recording and Playback of Voice Messages If you respond with a “1” at the menu, you will see the following Record/Playback prompt: RECORD/PLAYBACK? KEY [R/P]? First, we will playback a message that has already been recorded. Let’s use message #01 for this example. Press the P key (for Playback) to get to the next prompt: KEY [R/P]? MESSAGE #: _ At this prompt, enter a two digit number for the message number you want to listen to. Enter “01” and then press the ENTER key. You will probably hear the “ITEM” prompt recorded at the factory unless you have edited or reset the default messages. If you heard nothing, a new message can be safely recorded in the area assigned to message # 01. After you have heard the message (or static if no message has been recorded), the RF Terminal displays the RECORD/PLAYBACK prompt again: RECORD/PLAYBACK? KEY [R/P]? 7-3

Page 100

To record a message, get out the microphone (no, it’s not an earphone) shipped with the RF Terminal and plug it into the AUX jack located next to the POWER jack on the bottom of the RF Terminal. Answer the prompt by pressing the R key to record a message. The bottom line of the display now reads: MESSAGE #: _ Enter the message number you are going to record. For this example, enter message #03 (by default this is a blank message) by pressing 03, then the ENTER key. The RF Terminal screen now shows: HIT ANY KEY TO START RECORDING To record a message, press any key and hold it down. When you release the key, immediately start speaking into the microphone. To practice, let’s record something in message #03. Get ready to say ITEM (in English or your language) into the microphone of the RF Terminal. When ready, press the ENTER key and the instant you release it, speak ITEM into the microphone. Remember to speak clearly – you have plenty of time to say ITEM in ½ second. When the message time is over, you will hear two beeps. The display is back to the RECORD/PLAYBACK prompt: RECORD/PLAYBACK? KEY [R/P]? Now you’re ready to listen to your first recording. Press the P key and key in 03 for the message number. Do not be discouraged if you didn’t record the entire message. Our first attempt produced “EM” in a very frantic tone of voice. Practice speaking clearly and calmly (think of the poor guy who has to hear it 10,000 times next week) as soon as the key is released. You will get the hang of it with just a little practice. That is the way all messages – prompts and errors - are recorded. If you are not sure which message numbers are blank, you can listen to messages until you find a blank for recording. The host computer relies on the fact that the voice messages are stored in the RF Terminal itself and not generated by the host. The host computer will trigger the broadcast of a voice message by sending a prompt to the RF Terminal that tells it which message number to play. If the host thinks that message #05 is STOP when it’s really GO, it can cause confusion for the operator. That is why it is important to keep track of what messages are recorded where.

7-4